My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2301 COLBY AVE T MOBILE ANTENNA 2022-01-26
>
Address Records
>
COLBY AVE
>
2301
>
T MOBILE ANTENNA
>
2301 COLBY AVE T MOBILE ANTENNA 2022-01-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 3:45:03 PM
Creation date
5/3/2021 9:25:34 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2301
Tenant Name
T MOBILE ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIGNAGE NOTES: ro 0 0 0 <br />1. LOW LEVEL WARNING SIGNS -PLACE AT SITE ENTRY/ ACCESS POINTS ONLY: NOTICE A CAUTION <br />i. RDOF TOPS : PLACE SIGNS ON THE INSIDE OF ROOF HATCH: PLACE ON ACCESS <br />DOOR UNLESS DOOR IS USED BY GENERAL PUBLIC OR BUILDING TENANTS p p. <br />REGULARLY FOR ACCESS - IN THESE CASES CONSULT CONSTRUCTION MANAGER I N CASE O F <br />OR QC SUPERVISOR <br />if: WATER TANK. PLACE SIGNS ON COMPOUND GATE <br />iii. T-MOBILE - OWNED SITES: PLACE ONE SIGN ON SITE GATE EMERGENCY CALL <br />2. HIGH LEVEL CAUTION SIGNS - PLACE AT ALL ANTENNA SECTORS WHERE ACCESS BY <br />THE GENERAL PUBLIC TO THE ANTENNAS IS POSSIBLE: AA(v) <br />ALI. SIGNS WILL BE SECURED WITH EITHER STAINLESS STE'_LZIP TIED OR 1—888-662-4662 <br />STAINLESS TECH SCREWS <br />3. CABINET SIGNAGE SHALL BE PROVIDED BY T-MOBILE AND HAVE: <br />i. EXTERIOR LABELS THAT IDENTIFY THE MANUFACTURER AND MODEL NUMBER OF Site No.: SE01514A Beyond This Point you are entering an TE On this tower: NOTE <br />THE SYSTEM AND ELECTRICAL RATING (VOLTAGE AND CURRENT) OF THE area where RF emissions may exceed INSTALL PER Radio frequency fields at this site INSTALL PER <br />CONTAINED BATTERY SYSTEM. the FCC General Population Exposure MANUFACTURER may exceed the FCC rules for MANUFACTURER <br />Site Name :Civic Auditorium DT Colby Limits human exposure. ii. INTERIOR LABEL THAT INDICATED THE RELEVANT ELECTRICAL, CHEMICAL, AND O O SPECIFICATIONS AND FCC Po SPECIFICATIONS AND FCC <br />FIRE HAZARDS. AND T-MOBILE GUIDELINES Personal curbing mtr Lover sbouN be traifretl for AND T-MOBILE GUIDELINES <br />Fobw al po6llE signs ar,tl uiln 9uidernea for wortl,gn nmg'm rarAO frequency en rsandw <br />4. VRLA BATTERY SIGNAGE LOCATIONS IN COMPLIANCE WITH 2O14 OFC 608.7 WHERE an RF enr,onmam r,ersonm RF n,onaerawonewg near adore a�4 gym. <br />T•MOBILE BATTERY TECH AND/OR CONTRACTOR SHALL PLACE BATTERY DANGER SIGN. , , ,a,,,e,,,,� <br />BATTERY HAZ HAT SIGN, AND THERMAL RUNWAY PROCEDURE - PLACE AT ALL GATE p "'""`""'"""""` p p'""T"""""`^`�`""'°'"' ,,,imp <br />ENTRY/,ACCESS POINTS ONLY. <br />6. CC PARTICIPATION IN SIGN LOCATION: EMERGENCY CALL SIGN RF WARNING SIGN RF WARNING SIGN <br />i. CM WILL MEET WITH ALL CC'S TO CONFIRM LOCATIONS 2 3 <br />ii. CC WILL CALL OUT SIGN LOCATION(S) AT THE PRE -CON MEETING. NOT TO SCALE FNOT TO SCALE NOT TO SCALE <br />® NOTICE <br />(al1DLMF3 FOR WORKM N <br />RADIO FREOUENCY ENVIRONMENTS <br />er, Al personnel should have electromagnetic energy (EME) awareness training <br />is A.1 personnel entering this site must be authorized <br />A Obey all posted signs <br />Le Assume all antenna are active <br />A Before working on antennas, notify owners and disable appropriale transmitters <br />A,, Maintain minimum 3 feet clearance from all antennas <br />® Do not stop in front of antennas <br />i,, Use personal RF monitors while wotong near antennas <br />k. Never operate transmitters without shields during normal operation <br />(e Do not operate base station antennas in equipment room <br />4 GENERAL NOTICE SIGN <br />NOT TO SCALE <br />DANGER <br />THIS AREA CONTAINS. <br />LEAD -ACID BATTERY SYSTEMS. <br />CORROSIVE LIQUIDS (ELECTROLYTE). <br />ENERGIZED ELECTRICAL CIRCUITS. <br />AND HYDROGEN GAS <br />AUTHORIZED PERSONNEL ONLY <br />EYE PROTECTION REQUIRED <br />NO SMOKING OR OPEN FLAMES <br />BATTERY AREA <br />5 BATTERY D <br />NOT TO SCALE <br />NOTE <br />INSTALL PER <br />MANUFACTURER <br />SPECIFICATIONS AND FCC <br />AND T-MOBILE GUIDELINE <br />eC <br />�� <br />ll <br />Z <br />Y m <br />Ma, <br />L� <br />U� <br />Gj <br />O <br />O <br />0 <br />m <br />rn <br />E <br />(V LY N X <br />w <br />1133 164TH STREET SW <br />SUITE 202 <br />LYNNWOOD. WA 98087 <br />OFFICE'. (425) 778-7-A00 <br />JAYONEWWAVEAP: - <br />DATE- 8-21-20 <br />PREPARED BY, YML <br />APPROVED BY. JYS <br />SUBMITTALS <br />NO <br />DATE <br />DESCRIPTION <br />821-20 <br />IFINALPERMIT <br />&12-20 <br />REVISED PERMIT <br />&11-20 <br />REVISED PERMIT <br />7-3u-2u <br />PRELIMINARY PERMIT <br />7887 REGISTERED <br />R HITECT <br />JAY Y. S 0 <br />STA OF WASHNGTON <br />SITE <br />SE01514A <br />CIVIC AUDITORIUM <br />DT/COLBY <br />(ANCHOR) <br />2301 COLBY AVENUE, <br />EVERETT, WA 98201 <br />SHEET TITLE <br />SIGNAGE <br />DETAILS <br />SHEET NUMBER <br />A-5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.