Table002.1.1 Footnotes <br />For Sl:1 foot.=304.8 mm, ci .=continuous insulation, int.=intermediate framing. <br />a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less <br />than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table <br />A101.4 shal I not be less than the R-value specified in the table. <br />b Thefenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. <br />c "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation <br />on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at <br />the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the <br />interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall l. "10/13" means R- <br />10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the <br />basement wall. "TB" means thermal break between floor slab and basement wall. <br />d R-10 continuous insulation is required under heated slab on grade floors. See 11402.2.9.1. <br />eThere are no SHGC requirements in the Marine Zone. <br />f Reserved. <br />g Reserved. <br />h Reserved. <br />iThe second R-val ue applies when more than half the insulation is on the i nterior of the mass wal 1. <br />j Reserved. <br />k For single rafter-orjoist-vaulted ceilings, the insulation may be reduced to R-38. <br />I Reserved. <br />m Int. (intermediateframing) denotesstandard framing 16 incheson centerwith headers insulated with a minimum <br />ofR-10 insulation. <br />Table R402.1.3 Footnote <br />a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved sourceor as specified <br />in Section R402.1.3. <br />2 (w <br />
The URL can be used to link to this page
Your browser does not support the video tag.