Laserfiche WebLink
, <br /> --_ — <br /> _ _.-Pacific-Partners Insulation • <br /> r_.,A.ir Leakage Blower Door Testin : Certificate <br /> or Lot : '2S II 6' T t r. E-VGr-e- -•�- <br /> 0or-t cation: _.. l�n O 20 3O • <br /> 6 _mph • Humidity: <br /> Temperature: 6-0 ° F - Weather Condition: P...a.vl <br /> Formula: (CFMG.X 0.055) /(CFA X 144) Baseline: <br /> Calculations: <br /> 2.0a ' •oss-- 1/y. fir • <br /> 9-14-° )° Pik 321/1° = . bOD2956S <br /> Standard Tested CFMso Test Result(SLA) <br /> 0.00030 SLA 2.©90 <br /> • 0009 g6 3- <br /> Glossary <br /> CFA:Conditioned Floor Area <br /> CFMso:Cubic Feet per Minute of air leakage at 50 pascals of pressure <br /> Pascal(PA):The SI unit of pressure(equivalent to one newton per square meter) <br /> SLA:Specific Leakage Area <br /> _.NlashingtonState-Energy-Code-Reference: <br /> 502.4.5 Building Air Leakage Testing: All new construction and additions over 750 sq.ft.need to have a blower door test done and the <br /> resulting air leakage should be less than 0.00030 Specific Leakage Area(SLA)when tested at 50 pascals(0.2 inch w.g.)of depressurization.Testing <br /> can be done any time after rough in and after installation of penetrations of the building envelope,including penetrations for utilities,plumbing, <br /> electrical,ventilation and combustion appliances(and sealing of these penetrations)have been completed.Building officials can request that the <br /> test be conducted while building department staff is present.The blower door test results need to be recorded on the certificate that is required in <br /> Section 105.4 <br /> Exemptions: <br /> 1.Additions less than 750 square feet <br /> 2. Once visual inspection has confirmed the presence of a gasket(see section 502.4),operable windows and doors manufactured by small business <br /> shall be permitted to be sealed off at the frame prior to the test.Specific Leakage Area(SLA)shall be calculated as follows <br /> SLA =(CFM50 x 0.055)/(CFA x 144) <br /> Where: <br /> CFMso =Blower door fan flow at 50 pascal pressure difference <br /> CFA =Conditioned Floor Area of the housing unit,converted to square inches <br /> During Testing: <br /> Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed. <br /> Dampers shall be closed, but not sealed; including exhaust, intake, makeup air, back draft, and the flue dampers; interior doors connecting <br /> cored oon d ',pact'', shall be open; access hatches to conditioned uawl spaces and conditioned attics shall be opened: doors connecting to <br /> in , ,:(r+ iii,,il spa, ,. sh,rll b.. U., ed !jut not f.,,,,11._,{1. Lx[rrior opPnicp for cnLnuou; operati,,n ventil,+ti.�n ,y;t,•m ,and heat re,,iler'y ;entil.itor5 <br /> i-<;r= end d:_ << ,, 1 n�i : l �, ,,,• <br /> it I.i� it -i i if V Irl-` ,r -it, ,iI <br /> , . . . . . • JUCtil <br /> 11---$ - 13 . , . <br />