My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1020 N BROADWAY EVCC STUDENT HOUSING Geotech Report 2022-10-25
>
Address Records
>
N BROADWAY
>
1020
>
EVCC STUDENT HOUSING
>
Geotech Report
>
1020 N BROADWAY EVCC STUDENT HOUSING Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:44:24 PM
Creation date
5/3/2021 3:58:17 PM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
1020
Tenant Name
EVCC STUDENT HOUSING
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Footing <br /> Surcharge=q <br /> Br X <br /> * IIIIIIIiIIIItI <br /> 1 H:1 V Temporary Cut <br /> X X (if applicable) <br /> E Level Backslope <br /> 0.4 1-x/H III I <br /> . Soldier Pile Wall with H <br /> Timber Lagging <br /> • <br /> 3Br <br /> ADDIto <br /> Street traffic surcharge: bwtttto onlym of excavado a n • <br /> 80 psf uniform pressure <br /> Andy only to above <br /> bottom of excavation . Base of Excavation <br /> 1111 <br /> 40 pcf(1H:1V backstops) 350 pcf <br /> 35 pcf(level backslope) ,1 <br /> 17 <br /> Active Pressure Passive Pressure <br /> Notes: <br /> 1.Minumum embedment should be at least 10 feet below bottom of excavation. <br /> 2.A factor of safety of 1.5 has been applied to the recommended passive pressure values. <br /> No factor of safety has been applied to the recommended active earth pressure values. <br /> 3.Active pressures should be applied over the full width of the pile spacing above the <br /> base of the excavation,and over one pile diameter below the base of the excavation. <br /> 4.Surcharge pressures should be applied over the entire length of the loaded area. <br /> 5.Passive pressure should be applied to two times the diameter of the soldier piles. <br /> 6.Use 50%of the active and surcharge pressures for lagging design with soldier piles spaced <br /> at 8'or less. <br /> 7.Refer to report text for additional discussions. DESIGN L ER LWALL <br /> PRESSURES <br /> Proposed Apartments SOLDIER PILE <br /> WA <br /> LE WALL <br /> 1020 North Broadway CANTILEVERED <br /> Everett,Washington <br /> -cgProject No. 17-233 Figure No. 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.