• <br /> REPLY TO FIRST REVISION <br /> June 8, 2020 <br /> Owner: 3608 Rucker Ave LLC <br /> Job Address: To Be Determined <br /> Plan Check No: B2005-031 <br /> RE: Building Permit Review Letter <br /> Dear Mr. Mohammad, <br /> In response to the application for a building permit,the plans have been examined and you are advised that <br /> revisions are necessary before a permit can be issued. Please review and respond to the comments below. <br /> rovide all four elevations for the proposed single family residence. REVISED SHEET 3 <br /> Please revise the building section drawing to show the existing 2x4 walls, studs, blocking, rafters and <br /> plates. Show insulation in all walls floors and ceiling, including R-10 insulation at headers in furred <br /> out walls. REVISED SHEET 4&6 <br /> 'The plans show 2x8 floor joists with R-38 insulation required per option number la of the energy <br /> credits. Please specify the type of insulation you are proposing to use to obtain the required R-38. <br /> REVISED-FLOOR JOIST TO BE 2x10 w/R-38 BATT INSULATION (SHEET 6) <br /> J CI— 4. The Energy certificate on sheet 7 shows an Electric Forced Air Furnace, but the plans call for a <br /> ductless split system heat pump. Please correct. Show location of all electric heaters on plans and <br /> location of heat exchanger on site plan. REVISED SHEET 4&7 <br /> ikPft < Provide source specific exhaust fans in all laundry rooms, bathrooms and kitchen. Show on floor <br /> 0` ' plan(s). REVISED SHEET 4 <br /> Specify which "Whole House Ventilation System" per section M1507.3.3 you will be using. Provide <br /> the requirements of the whole house ventilation system you will be using, do not simply reference <br /> the code section (whole house exhaust fans one rating shall be 1.0 or less). REVISED(CHANGE OF <br /> ,...ENERGY CREDITS SELECTED) <br /> Provide minimum 36-inch (level) landing at all exterior entrance/exits not more than 7-3/4" below <br /> the finished floor.Show on plans and site plan. REVISED SHEET 4 & 1 <br /> Show the dimensions of the proposed parking spaces on the site plan, exclusive of the landing at the <br /> 5P44C.64 T,ocv west side of the dwelling REVISED SHEET 1 SITE PLAN <br /> fr��uiG 9. All section drawings should show all framing members. Show all plates headers blocking etc. <br /> WISED SHEET4 &6 <br /> Provide attic ventilation calculations. Show size and location of all attic ventilation on plans. <br /> .kq 64. REVISED SHEET 4 <br /> S'R4c.N Provide insulation baffles to maintain minimum 1" clear air space over insulation. Baffle shall extend <br /> minimum 12 inches vertically above the insulation. Show requirement on plans. REVISED SHEET 6 <br /> Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.