My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1700 13TH ST 9TH FLOOR 2022-01-20
>
Address Records
>
13TH ST
>
1700
>
9TH FLOOR
>
1700 13TH ST 9TH FLOOR 2022-01-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2022 3:05:06 PM
Creation date
5/4/2021 2:09:34 PM
Metadata
Fields
Template:
Address Document
Street Name
13TH ST
Street Number
1700
Tenant Name
9TH FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
925 Fourth Avenue <br />Suite 2400 ' Memo <br />Seattle, WA 98104 <br />ZGFT 206 623 7868 Date March 21 2019-- <br />F 206 623 7868 � <br />Project No. S24009 <br />ZIMMER GUNSUL FRASCA ARCHITECTS LLP Project Name PRMCE — D Wing Level 9 <br />Inpatient Unit Buildout <br />Page No. 3 of 6 <br />3. Please confirm that doors opening into the corridors do not utilize roller latches. Section 407.3.1 <br />Response: Confirmed. Doors opening into corridors are to meet Section 407.3.1. <br />4. Please confirm that the doors leading from the electrical rooms are either provided with panic hardware or are not <br />required to have panic devices per Section 1010.1.10.3 <br />Response: Notes have been added to sheet A8.41 to show panic hardware in compliance with section 1010.1.10.3. <br />5. Please confirm that the existing electrical rooms are not required to have two means of egress per Section 1006.2.2.6 and <br />NEC Article 110.26 (C)(3). <br />Response: Confirmed. Only one means of egress is required per Section 10006.2.2.6. <br />6. The locations, use -instructions and signage requirements for the two-way communication system at the elevator landings <br />should be shown on the plans. Section 1009.8 <br />Response: Locations have been added for emergency communication and signage on service elevator have been indicated on <br />plans and added to elevations. See elevation drawing 7/A7.04 and additional elevation 16/A7.03 f6r elevations. <br />7. Any electric/electromechanical controlled egress doors proposed should be shown to comply with Section 1010.1.9.6. <br />Response: Notes have been added to sheet A8.42 to show compliance with section 1010.1.9.6. <br />Accessibility: <br />1. The flushing mechanisms are shown on the near side of the toilet stalls on the typical mounting location drawings of Sheet <br />A7.01. ANSI Section 604.6 <br />Response: Accessibility Note #2 on sheet A7.01 indicates compliance with ANSI 604.6. The flushing mechanisms have been <br />relocated to the near side of the toilet stalls in the elevation drawings on A7.01. <br />2. The drains and hot water supply on the lav's should be shown protected or insulated to prevent contact. ANSI Section <br />606.6 <br />Response: Note on detail 2/A8.35 indicates to provide pipe insulation per ADA. Additional standard mounting height details <br />have been added to sheet A7.01 to indicated insulated pipes. <br />3. The shower seat should be shown to be within 3" of the compartment entry (vs. the shower entry) in detail 12/A6.01. <br />ANSI Section 610.3 <br />Response: Detail 12/A6.01 has been deleted. See drawings 5, 6, & 11 on A6.01 for ADA seat locations. Shower seats are to be <br />within 3" of compartment entry per ANSI Section 610.3. <br />3i 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.