Laserfiche WebLink
,.-•,lFORTE MEMBER REPORT Upper Floor Framing, U-01 Floor joist PASSED <br /> 1 piece(s) 11 7/8" TM® 210 @ 16" OC <br /> Overall Length:20' <br /> ,.�r. �r•r tee,. ,. .. ._ ,. .,..� r _ �y:. _ . <br /> • _ ,.,n N_e ,. <br /> + + <br /> 20' <br /> 0 0 <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual <br /> Design Results Actual©Location .'Allowed Result- ':..,. LDF toad:Combination(Pattern) System:Floor <br /> Member Reaction(lbs) 654 @ 2 1/2" 1134(2.25") Passed(58%) 1.00 1.0 D+1.0 L(All Spans) Member Type:Joist <br /> Shear(Ibs) 642 @ 3 1/2" 1655 Passed(39%) 1.00 1.0 D+1.0 L(All Spans) Building Use:Residential <br /> Moment(Ft-lbs) 3142 @ 9'11" 3795 Passed(83%) 1.00 1.0 D+1.0 L(All Spans) Building Code:IBC 2015 <br /> Live Load Deft(in) 0.486 @ 9'11" 0.647 Passed(L/480) -- 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> Total Load Defl.(in) 0.607 @ 9'11" 0.971 Passed(L/384) -- 1.0 D+1.0 L(All Spans) <br /> i TJ-Pro"Rating 32 Any Passed -- - <br /> • Deflection criteria:LL(L/360)and TL(1/240). <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 4'o/c unless detailed otherwise. <br /> • Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 19'10"o/c unless detailed otherwise. <br /> • A structural analysis of the deck has not been performed. <br /> • Deflection analysis is based on composite action with a single layer of 23/32"Weyerhaeuser Edge""Panel(24"Span Rating)that is glued and nailed down. <br /> • Additional considerations for the TJ-Pro'"Rating include:None <br /> Bearing Loads to Supports(Ibs) - <br /> Supports Total Available Required Dead Floor Total Accessories <br /> Live <br /> 1-Stud wall-HE 3.50" 2.25" 1.75" 132 529 661 1 1/4"Rim Board <br /> 2-Stud wall-HF 5.50" 4.25" 1.75" 134 538 672 1 1/4"Rim Board <br /> •Rim Board is assumed to carry all loads applied directly above it,bypassing the member being designed. <br /> Dead Floor Live <br /> Loads Location(Side) Spacing (0.90) (1.00) Comments <br /> 1-Uniform(PSF) 0 to 20' 16" 10.0 40.0 Residential-Living <br /> Areas <br /> Member Notes <br /> Typical floor joist <br /> f�� <br /> Weyerhaeuser,Notes (2}SUSTAINABLE FORESTRY INITIATIVE <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. <br /> Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. <br /> (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to <br /> circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to <br /> assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable <br /> forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in <br /> accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. <br /> The product application,input design loads,dimensions and support information have been provided by Forte Software Operator <br /> Porte Software Operator Job Notes 1/6/2017 10:24:05 AM <br /> D Pcns:fi Forte v5.2.Design Engine:VI6.6.0.14 <br /> Duplex 1470 <br /> Dr.eier : c Duplex 1470.-2,`e <br /> Page 1C____Isa <br />