- MEMBER REPORT Upper Floor Framing, U-03 Microllam at stair PASSED <br /> E 1 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam® LVL @ 16" OC <br /> Overall Length: 12' <br /> ... a<k; <br /> o t --_. 0 <br /> rig <br /> 4' 12' 'I, <br /> 11 II <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual <br /> I'Design Results Actual 0 Location Allowed Result LOP Load:Combination(Pattern) System:Floor <br /> Member Reaction(Ibs) 1111 @ 2 1/2" 2481(3.50") Passed(45%) -- 1.0 D+1.0 L(All Spans) Member Type:Joist <br /> Shear(Ibs) 562 @ 1'3 3/8" 3948 Passed(14%) 1.00 1.0 D+1.0 L(All Spans) Building Use:Residential <br /> Moment(Ft-Ibs) 1264 @ 5'5 5/8" 9281 Passed(14%) 1.00 1.0 D+1.0 L(All Spans) Building Code:IBC 2015 <br /> Live Load Defl.(in) 0.050 @ 5'9 7/16" 0.381 Passed(L/999+) -- 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> Total Load Dell.(in) 0.063 @ 5'9 7/16" 0.571 Passed(L/999+) — 1.0 D+1.0 L(All Spans) <br /> TJ-Pro'"Rating 65 40 Passed -- -- <br /> Deflection criteria:LL(L/360)and TL(L/240). <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 11'11"o/c unless detailed otherwise. <br /> • Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 11'11"o/c unless detailed otherwise. <br /> • A 4%increase in the moment capacity has been added to account for repetitive member usage. <br /> •A structural analysis of the deck has not been performed. <br /> • Deflection analysis is based on composite action with a single layer of 23/32"Weyerhaeuser Edge"Panel(24"Span Rating)that is glued and nailed down. <br /> •Additional considerations for the TJ-Pro'"Rating include:None <br /> - — Bearing Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Floore Total Accessories <br /> Liv <br /> 1-Stud wall-HF 3.50" 3.50" 1.57" 229 883 1112 Blocking <br /> 2-Stud wall-HF 5.50" 4.25" 1.50" 87 348 435 1 1/4"Rim Board <br /> •Rim Board is assumed to carry all loads applied directly above it,bypassing the member being designed. <br /> •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br /> Dead Floor Live 1 <br /> Loads Location(Side) Spacing (0.90) (1.00) Comments <br /> 1-Uniform(PSF) 0 to 12' 16" 10.0 40.0 Residential-Living <br /> Areas <br /> Linked from:U-02 <br /> 2-Point(lb) 8" N/A 156 591 Stair header, <br /> Support 1 <br /> rMernber Notes <br /> Microllam supporting stair header <br /> //�� I <br /> Weyerhaeuser Notes (I)SUSTAINABLE FORESTRY INITIATIVE <br /> i Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. `�� <br /> Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. <br /> (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to <br /> circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to <br /> assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable <br /> forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in <br /> accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. <br /> The product application,input design loads,dimensions and support information have been provided by Forte Software Operator <br /> Forte Software Operator Job Notes 116/20 17 10:24:05 AM <br /> ;r"=;! Du;;I::x 1�70 Forte v5.2.Design Engine:V6.6.0 14 <br /> _i::=:s Duplex 147 0.4te <br /> ..z I t-.. PageJ.�^f-3 <br />