Laserfiche WebLink
0 R E MEMBER REPORT Upper Floor Framing, U-05 Parallam at upper level PASSED <br /> 1 piece(s) 3 1/2" x 11 7/8" 2.0E Parallam® PSL <br /> Overall Length:20' <br /> + + <br /> o — o <br /> .1' .1" <br /> , <br /> 0 0 <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual <br /> Design Results Actual t Location Allowed Result LOF Load:Combination(Pattern) System:Floor <br /> Member Reaction(lbs) 1682 @ 2" 3189(2.25") Passed(53%) -- 1.0 D+ 1.0 L(All Spans) Member Type:Flush Beam <br /> Shear(lbs) 1533 @ 1'3 3/8" 8035 Passed(19%) 1.00 1.0 D+1.0 L(All Spans) Building Use:Residential <br /> Moment(Ft-lbs) 9647 @ 8'8" 19902 Passed(48%) 1.00 1.0 D+1.0 L(All Spans) Building Code:IBC 2015 <br /> Live Load Deft.(in) 0.344 @ 9'8 7/16" 0.650 Passed(L/681) -- 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> Total Load Defl.(in) 0.621 @ 9'7 5/16" 0.975 Passed(L/377) -- 1.0 D+1.0 L(All Spans) <br /> • Deflection criteria:LL(L/360)and TL(L/240). • <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 19'10"o/c unless detailed otherwise. <br /> • Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 19'10"o/c unless detailed otherwise. <br /> Bearing Loads to Supports(Ibs) <br /> Supports Total Available Required Dead loor ve Total Accessories <br /> 1-Stud wall-HF 3.50" 2.25" 1.50" 883 811 1694 1 1/4"Rim Board <br /> 12-Column-DF 5.50" 4.25" 1.50" 519 724 1243 1 1/4"Rim Board <br /> •Rim Board is assumed to carry all loads applied directly above it,bypassing the member being designed. <br /> 1 Tributary Dead Floor Live <br /> I Loads Location(Side) Width (0.90) (1.00) Comments <br /> 0-Self Weight(PLF) 1 1/4"to 19'10 N/A 13.0 <br /> 3/4" <br /> 1-Uniform(PSF) 0 to 20'(Top) 1' 10.0 40.0 Residential-Uving <br /> Areas <br /> 2-Uniform(PLF) 0 to 8'8"(Top) N/A 64.0 residential interior <br /> wall(non-bearing) <br /> Linked from:U-04 <br /> 3-Point(lb) 8'8"(Front) N/A 391 735 Microllam at upper <br /> level,Support 1 <br /> Member Notes <br /> Parallam at line of stair opening /� <br /> Weyerhaeuser Notes 1 SUSTAINABLE FORESTRY INITIATIVE <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. l <br /> Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. <br /> (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to <br /> circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to <br /> assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable <br /> forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in <br /> accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. <br /> The product application,input design loads,dimensions and support information have been provided by Forte Software Operator <br /> Forte',Loll-tam Operator Job Notes 1116/2017 10:24:05 AM <br /> Duplex 147C Forte v5.2.Design Engine:V6.6.0.14 <br /> Duplex 1470.4te <br /> Page 14 <br />