My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1913 HOYT AVE WHOLE SITE 2022-05-23
>
Address Records
>
HOYT AVE
>
1913
>
WHOLE SITE
>
1913 HOYT AVE WHOLE SITE 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 7:57:47 AM
Creation date
5/4/2021 2:11:26 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
1913
Tenant Name
WHOLE SITE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIRE DEPARTMENT ElI ►- I <br /> TO: Kelsey Heyd, Planning <br /> FROM: Jim Venturo,Assistant Fire Marshal <br /> DATE: March 27, 2017 <br /> SUBJECT: Pre-App 17-004 <br /> New four unit multi-family apartment <br /> 1913 Hoyt Ave <br /> 1. Access -O.K. as shown on the site plan reviewed. <br /> 2. A Knox Box is required. 2015 IFC 506.1 <br /> Order box#1658 for access to sprinkler room at www.everettfire.org <br /> 3. Knox fire department connection caps are required for all OUTSIDE FDC and standpipe <br /> connection points. <br /> Order cap#3043 for 2-1/2"sprinkler connection at www.everettfire.ora <br /> 4. Fire flow for this project is 1,500 gpm. <br /> 5. Fire Suppression (Sprinkler) System-An approved automatic suppression system shall be provided <br /> as required by City Ordinance No. 3021-07, EMC, Chapter 16.76. <br /> Plans for any such system shall be submitted to the Engineering & Public Services Department for <br /> examination and approval. Such plans shall include plans for the underground mains that will <br /> supply the sprinkler system. <br /> The type of sprinkler to be installed will be determined by the Building Official. It may be an NFPA <br /> 13, NFPA 13R, or NFPA 13D system depending upon several factors. Sprinkler installation shall <br /> not begin without an approved and stamped set of plans from the Engineering & Public <br /> Services Department. The Fire Department will also review the plans and shall field inspect the <br /> installation based only on approved plans that must be on site. Changes to plans must be <br /> • approved by both the Engineering & Public Services and Fire Departments. <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br /> Underground piping shall be hydrostatically tested and flushed as established in NFPA Standard 24 <br /> for private fire mains. (Below-ground piping must be installed by Washington State Licensed <br /> Underground Sprinkler line certified "U" installers. For further information, contact the State <br /> Fire Marshal's Office at(360) 596-3900 or contact the Everett Fire Department at(425) <br /> 257-8124.) All such tests shall be witnessed by a Fire Department inspector. Call (425) 257-8124 <br /> or(425)257-8120 to make an appointment for inspection. <br /> Contractors' materials and test certificates shall be submitted to the Everett Fire Department prior to <br /> issuance of any Certificates of Occupancy. 2015 IFC, WA State Amendment 903.3.5.3, Page 111. <br /> Call (425) 257-8124 for more information. <br /> EVERETT FIRE DEPARTMENT•2930 Wetmore Avenue Ste 7A•Everett WA 98201-4067•(425)257-8100• Fax(425)257-8139 <br />
The URL can be used to link to this page
Your browser does not support the video tag.