, ECHELBARGER- 3 STORY I February 1, 2018 I SDA Job# 7976 I 9 <br /> LOWER LEFT/RIGHT WALL SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> LOWER Floor Level,e g Upper,Main,Lower 1 0 tributary width 1.0 tributary area <br /> Ft-Rr Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2 0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type 1 0 tributary width 1 0 tributary area <br /> Values from table 4 3A of the AF&PA SDPWS-2008 2.0 total width 2.0 total area <br /> M/FL Resisting Dead Load Tributary Width(Lower Floor) Tributary Area(Lower Floor) <br /> (e g Roof,Upper Floor,Main Floor) 1 0 tributary width 1.0 tributary area <br /> 24.00 ft Total Length of Shearwalls 2 0 total width 2 0 total area <br /> V(from upper)= 4217 lb 8099 lb Height of Shearwall= 8.0 ft Weight of Shearwall= 10 0 lbs <br /> V(from main)= 4003 lb 4531 lb Length of Shearwall= 24 0 ft Tributary width for dead load= 10.0 ft <br /> V(from lower)= 4003 lb 1901 lb Length of adjoining wall= 4 0 ft <br /> E(0tv8)= 12,223 lb E(Eµx)= 14,530 lb Use alternate R factor for seismic? No <br /> V= 255 PLF v= 303 PLF <br /> AF&PA SDPWS-2008 0.93 x 360= 335 PLF USE L <br /> seismic(---- is shearw_ <br /> CTOTAL= (floor above)+(this floor)= 810 + 2037 lbs = 2847 lbs Wind controls <br /> TTOTAL= (floor above)+(this floor)= 149 + 163 lbs = 312 lbs Load case 8 controls-Seismic <br /> 6eisrriic controls hoiL, <br /> NO HOLDOWNS REQUIRED OK <br /> Where overstrength factor is applicable,use this <br /> value for E in equations 5,6,and 8: E= 1863 lbs <br /> MOMENT FRAME SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> LOWER Floor Level,e.g.Upper,Main,Lower 1.0 tributary width 1.0 tributary area <br /> Ft-Rr Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type 1.0 tributary width 1.0 tributary area <br /> Values from table 4.3A of the AF&PA SDPWS-2008 2.0 total width 2 0 total area <br /> M/FL Resisting Dead Load Tributary Width(Lower Floor) Tributary Area(Lower Floor) <br /> 1.0 tributary width 1.0 tnbutary area <br /> 40.00 ft Total Length of Shearwalls 2.0 'total width 2.0 total area <br /> V(from upper)- 4217 lb 15041 lb Height of Shearwall= Weight of Shearwall= ,y <br /> V(from main)... 4003 lb 8414 lb Length of Shearwall= Tributary width for dead load= <br /> V(from lower). 4003 lb 3530 lb Length of adjoining wall= <br /> E(Ihv8)= 12,223 lb L(Eµ)0= 26,985 lb Use alternate R factor for seismic? YES If yes,enter factor= 3.5 <br /> v= 153 PLF v 2 337 PLF <br /> AF&PA SDPWS-2008 #DIV/01 0 93 x #DIV/01 #DIV/01 USE <br /> CTOTAL= (floor above)+(this floor)= 1548 + 0 lbs = 1548 lbs #DIV/ot <br /> TTOTAL= (floor above)+(this floor)= -1132 + #DIV/01 = #DIV/01 #DIV/0! <br /> 1 Where overstrength factor is applicable,use this #DIV/01 #DIV/01— <br /> value for E in equations 5,6,and 8: E= 0 lbs ######_ #DIV/0! <br /> NOT USED SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> MAIN Floor Level,e.g.Upper,Main,Lower 1 0 tributary width 1 0 tributary area <br /> Ft-Rr Load Direction,e.g Left-Right, Front-Rear 2 0 total width 2.0 total area <br /> (For Left Wail,Use Front-Rear Load Direction) Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type 1.0 tributary width 1 0 tributary area <br /> Values from table 4 3A of the AF&PA SDPWS-2008 2 0 total width 2.0 total area <br /> ROOF Resisting Dead Load Tributary Width(Lower Floor) Tributary Area(Lower Floor) <br /> (e.g.Roof,Upper Floor,Main Floor) tributary width tributary area <br /> 16.50 ft Total Length of Shearwalls total width total area <br /> V(from upper)= 4217 lb 8099 lb Height of Shearwall= 8 0 ft Weight of Shearwall= 10 0 lbs <br /> V(from main)= 4003 lb 4531 lb Length of Shearwall= 3.5 ft Tributary width for dead load= 2 0 ft <br /> V(from Tower)= 0 lb 0 lb Length of adjoining wall= _ 4 0 ft <br /> E(12rv5)= 8,220 lb E(Eµx)= 12,630 lb Use alternate R factor for seismic? no <br /> v= 249 PLF V= 383 PLF <br /> AF&PA SDPWS-2008 (2w/h) x 0 93 x 510=415 PLF USE <br /> o/s shearwall design <br /> CTOTAL= (floor above)+(this floor)= 1548 + 2143 lbs = 3691 lbs Seismic controls <br /> TTOTAL= (floor above)+(this floor)= -1132 + 1840 lbs = 708 lbs Load case 8 controls-Seismic <br /> Where overstrength factor is applicable,use this USE SIMPSON DESIGNED HOLDOWN CS14 <br /> I value for E in equations 5,6.and 8: E= 2355 lbs , OR AT FOUNDATION/INTERIOR WALLS USE: LSTHD8/RJ <br />