Laserfiche WebLink
STRUCTURAL DESIGN ASSOCIATES Project Title: <br /> Engineer: Project ID: SDA#7976 <br /> Project Descr: <br /> Printed:2 FEB 2018,8:21AM <br /> 2-D Frame FIe=klaspenneMrodcfiles1PROJECTS17300-7-117976179764.1.EC6 <br /> ENERCALC,INC.1983-2017,Build:10.17.12.10,Ver:10,17.12.10 <br /> Lic.#: KW-06011301 Licensee:Covington <br /> Strength/Stress Load Combinations ASCE 7-10 <br /> Load Combination Cd ( Load Combination Factors <br /> Description Dead Roof Live Live Snow Seismic Wind Earth <br /> +D+H 0.9 1.0 1.0 <br /> +D+L+H 1 10 1.0 1.0 <br /> +D+Lr+H 1.25 1.0 1.0 1.0 <br /> +D+S+H 1.15 1.0 1.0 1.0 <br /> +D+0,750Lr+0.750L+H 1.25. 1A 0.750 0.750 1.0 <br /> +D+0.750L+0.750S+H 1.15 1.0 0.750 0.750 1.0 <br /> +D+0.60W+H 1.6 1.0 0.60 1.0 <br /> +D+0.70E+H 0.9 1.0 0.7 1.0 <br /> +D+0.750Lr+0.750L+0.450W+H 1.6 1.0 0.750 0.750 0.450 1.0 <br /> +D+0.750L+0.750S+0.450W+H 1.6 1.0 0.750 0.750 0.450 1.0 <br /> +D+0.750L+0.750S+0.5250E+H 1.15 1.0 0.750 0.750 0.525 1.0 <br /> +0.60D+0.60W+0.60H 1.6 0.60 0.60 0.60 <br /> +0.60D+0.70E+0.60H 0.9 0.60 0.7 0.60 <br /> Reaction Load Combinations ASCE 7-10 <br /> Load Combination Load Combination Factors <br /> Description Dead Roof Live Live Snow Seismic Wind Earth <br /> +D+H 1.0 1.0 <br /> +D+L+H 1.0 1.0 1.0 <br /> +D+Lr+H 1.0 1.0 1.0 <br /> +D+S+H 1.0 1.0 1.0 <br /> +D+0.750Lr+0.7501+H 1.0 0.750 0.750 1.0 <br /> +D+0.750L+0.7505+H 1.0 0.750 0.750 1.0 <br /> +D+0.60W+H 1,0 0.60 1.0 <br /> +D+0.70E+H 1.0 0.70 1.0 <br /> +D+0.750Lr+0.750L+0.450W+H 1.0 0.750 0.750 0.450 1.0 <br /> +D+0.750L+0.750S+0.450W+H 1.0 0.750 0.750 0.450 1.0 <br /> +D+0.750L+0.750S+0.5250E+H 1.0 0.750 0.750 0.5250 1.0 <br /> +0.60D+0.60W+0.60H 0.60 0.60 0.60 <br /> +0.60D+0.70E+0.60H 0.60 0.70 0.60 <br /> D Only 1.0 <br /> Lr Only 1.0 <br /> L Only 1.0 <br /> S Only 1.0 <br /> W Only 1.0 <br /> E Only 1.0 <br /> H Only 1.0 <br /> Deflection Load Combinations ASCE 7.10 <br /> Load Combination Load Combination Factors <br /> Description Dead Roof Live Uve Snow Seismic Wind Earth <br /> +D+H 1.0 1.0 <br /> +D+L+H 1 1.0 1.0 1.0 <br /> +D+Lr+H 1.0 1.0 1.0 <br /> +D+S+H 1.0 1.0 1.0 <br /> +D+0.750Lr+0.7501+H 1.0 0.750 0.750 1.0 <br /> +D+0,7501+0.7505+H 1.0 0.750 0.750 1.0 <br /> +D+0.60W+H 1.0 0.60 1.0 <br /> +D+0.70E+H 1.0 0.70 1.0 <br /> +D+0.750Lr+0.750L+0.450W+H 1.0 0.750 0.750 0.450 1.0 <br /> +D+0.750L+0.750S+0.450W+H 1.0 0.750 0.750 0.450 1.0 <br /> +D+0.750L+0.750S+0.5250E+H 1.0 0.750 0.750 0.5250 1.0 <br /> +0.600+0.60W+0.60H 0.60 0.60 0.60 <br /> +0.600+0.70E+0.60H 0.60 0.70 0.60 <br /> D Only 1.0 <br /> Lr Only 1.0 <br /> L Only 1.0 <br /> S Only 1.0 <br /> W Only 1.0 <br /> E Only I 1.0 <br />