Laserfiche WebLink
ECHELBARGER- 3 STORY I December 4, 2018 I SDA Job # 7976 I 6 <br /> UPPER FRONT WALL SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> UPPER 1 Floor Level,e.g.Upper,Main,Lower 1.0 tributary width 1.0 tributary area <br /> Lt-Rt I Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type _tributary width tributary area <br /> Values from table 4.3A of the AF&PA SDPWS-2008 total width total area <br /> ROOF Resisting Dead Load Tributary Width(Lower Floor) Tributary Area(Lower Floor) <br /> (e.g.Roof,Upper Floor,Main Floor) tributary width tributary area <br /> _23.50 ft Total Length of Shearwalls total width total area <br /> V(from upper)= 4097 lb 6227 lb Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 Ibs <br /> V(from main)= 0 lb 0 lb Length of Shearwall= 5.0 ft Tributary width for dead load= 10.0 ft <br /> V(from lower)= 0 lb 0 lb Aspect Ratio OK Length of adjoining wall= 4.0 ft <br /> E(Wind)= 4,097 lb F(Smc)= 6,227 lb Use alternate R factor for seismic? NO <br /> v= 87 PLF v= 132 PLF <br /> AF&PA SDPWS-2008 0.93 x 230= 214 PLF USE A <br /> Seismic controls shearwall design <br /> CTOTAL= (floor above)+(this floor)= + 742 lbs = 742 lbs Seismic controls <br /> TTOTAL= (floor above)+(this floor)= + 98 lbs = 98 lbs Load case 8 controls-Wind <br /> Wind controls holdown design <br /> NO HOLDOWNS REQUIRED OK <br /> Where overstrength factor is applicable,use this <br /> value for E in equations 5,6,and 8: E= 1060 lbs <br /> UPPER REAR WALL SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> UPPER Floor Level,e.g.Upper,Main, Lower 1.0 tributary width 1.0 tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type tributary width tributary area <br /> Values from table 4.3A of the AF&PA SDPWS-2008 total width total area <br /> ROOF Resisting Dead Load Tributary Width(Lower Floor) Tributary Area(Lower Floor) <br /> (e.g.Roof,Upper Floor,Main Floor) tributary width tributary area <br /> 19.00 ft Total Length of Shearwalls total width total area <br /> V(from upper)= 4097 lb 11565 lb Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 lbs <br /> V(from main)= 0 lb 0 lb Length of Shearwall= 2.5 ft Tributary width for dead load= 10.0 ft <br /> V(from lower)= 0 lb 0 lb Aspect Ratio OK Length of adjoining wall= 4.0 ft <br /> E(52tv8)= 4,097 lb E(Eµx)= 11,565 lb Use alternate R factor for seismic? YES If yes,enter factor= 3.5 <br /> v= 108 PLF v= 304 PLF <br /> AF&PA SDPWS-2008 (2w/h) x 0.93 x 665=387 PLF USE <br /> Seismic controls shearwall de,,.,. <br /> CTOTAL= (floor above)+(this floor)= + 1704 lbs = 1704 lbs Seismic controls <br /> TTOTAL= (floor above)+(this floor)_ + 1126 lbs = 1126 lbs Load case 8 controls-Seismic <br /> Seismic controls holdown design ii <br /> Where overstrength factor is applicable,use this ry USE SIMPSON DESIGNED HOEDOWN: f <br /> value for E in eguations 5,6,and 8: E= 2435 lbs - OR AT FOUNDATION/INTERIOR WALLS USE: LSTHD8/RJ <br /> UPPER LEFT/RIGHT WALL SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> UPPER Floor Level,e.g.Upper,Main, Lower 1.0 tributary width 1.0 tributary area <br /> Ft-Rr Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type tributary width tributary area <br /> Values from table 4.3A of the AF&PA SDPWS-2008 total width total area <br /> ROOF Resisting Dead Load Tributary Width(Lower Floor) Tributary Area(Lower Floor) <br /> (e.g.Roof,Upper Floor,Main Floor) tributary width tributary area <br /> 28.00 ft Total Length of Shearwalls total width total area <br /> V(from upper)= 4217 lb 6227 lb Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 lbs <br /> V(from main)= 0 lb 0 lb Length of Shearwall= 4.0 ft Tributary width for dead load= 10.0 ft <br /> V(from lower)= 0 lb 0 lb Aspect Ratio OK Length of adjoining wall= 4.0 ft <br /> E(S2tv8)= 4,217 lb E(Eµx)= 6,227 lb Use alternate R factor for seismic? No <br /> v= 75 PLF v= 111 PLF <br /> AF&PA SDPWS-2008 0.93 x 230= 214 PLF USE A <br /> Seismic controls shearwall design <br /> CTOTAL= (floor above)+(this floor)_ + 623 lbs = 623 lbs Seismic controls <br /> TTOTAL= (floor above)+(this floor)= + 49 lbs = 49 lbs Load case 8 controls-Wind <br /> ols holdown design <br /> Where overstrength factor is applicable,use this NO HOLDOWNS REQUIRED OK <br /> value for E in equations 5,6,and 8: E= 890 lbs <br /> J <br />