My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1913 HOYT AVE C D 2022-05-23
>
Address Records
>
HOYT AVE
>
1913
>
1913 HOYT AVE C D 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 7:58:47 AM
Creation date
5/4/2021 2:49:50 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
1913
Unit
C D
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
127
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ECHELBARGER- 3 STORY I January 9, 2019 I SDA Job # 7976 I 9 <br /> LOWER LEFT/RIGHT WALL SHEARWALL WIND SEISMIC <br /> 'Floor Info • Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> LOWER Floor Level,e.g. Upper, Main, Lower 1.0 tributary width 1.0 tributary area <br /> Ft-Rr Load Direction,e.g. Left-Right, Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type 1.0 tributary width 1.0 tributary area <br /> Values from table 4.3A of the AF&PA SDPWS-2008 2.0 total width 2.0 total area <br /> M/FL Resisting Dead Load Tributary Width(Lower Floor) Tributary Area(Lower Floor) <br /> (e.g.Roof,Upper Floor,Main Floor) 1.0 tributary width 1.0 tributary area <br /> 24.00 ft Total Length of Shearwalls 2.0 total width 2.0 total area <br /> V(from upper)= 4217 lb 6227 lb Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 Ibs l <br /> V(from main)= 4003 lb 3483 lb Length of Shearwall= 24.0 ft Tributary width for dead load= 10.0 ft <br /> V(from lower)= 4003 lb 1894 lb =;p- ;i=<,., " Length of adjoining wall= _ 4.0 ft <br /> E(Qw6)= 12,223 lb E(E).1x)= 11,605 lb Use alternate R factor for seismic? No <br /> V= 255 PLF V= 242 PLF <br /> AF&PA SDPWS-2008 0.93 x 360=335 PLF USE <br /> Seismic controls shearwall de-sign <br /> CTOTAL= (floor above)+(this floor)= 623 + 2037 lbs = 2660 lbs Wind controls <br /> TTOTAL= (floor above)+(this floor)= _ 49 + 117 lbs = 166 lbs Load case 8 controls-Wind <br /> Wind controls holdown design <br /> NO HOLDOWNS REQUIRED OK <br /> Where overstrength factor is applicable,use this <br /> value for E in equations 5,6,and 8: E= 1934 lbs <br /> MOMENT FRAME SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> LOWER Floor Level,e.g. Upper, Main, Lower 1.0 tributary width 1.0 tributary area <br /> Ft-Rr Load Direction,e.g. Left-Right, Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type 1.0 tributary width 1.0 tributary area <br /> Values from table 4.3A of the AF&PA SDPWS-2008 2.0 total width 2.0 total area <br /> M/FL Resisting Dead Load Tributary Width(Lower Floor) Tributary Area(Lower Floor) <br /> 1.0 tributary width 1.0 tributary area <br /> 40.00 ft Total Length of Shearwalls 2.0 total width 2.0 total area <br /> V(from upper)= 4217 lb 11565 lb Height of Shearwall= Weight of Shearwall= <br /> V(from main)= 4003 lb 6469 lb Length of Shearwall= Tributary width for dead load= <br /> V(from lower)= 4003 lb 3518 lb 4 )1,1,0! Length of adjoining wall= <br /> E(0iv6)= 12,223 lb E(Eµx)= 21,552 lb Use alternate R factor for seismic? YES If yes,enter factor= 3.5 <br /> V= v <br /> 3x framing required per IBC <br /> AF&PA SDPWS-2008 #DIV/0! 0.93 x_ #DIV/0! #DIV/0! USE ## <br /> #DI`i10' #DIV/D.! <br /> CTOTAL= (floor above)+(this floor)= + 0 lbs = 0 lbs #DIV/0l <br /> TTOTAL= (floor above)+(this floor)= + #DIV/0! = #DIV/0! #DIV/0! <br /> tr, <br /> r Where overstrength factor is applicable,use this #DIV/0! #DIV/01 <br /> value for E in equations 5,6,and 8: E= 0 lbs ; #I #DIV/0! <br /> NOT USED SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> _ MAIN Floor Level,e.g. Upper, Main, Lower 1.0 tributary width 1.0 tributary area <br /> Ft-Rr Load Direction,e.g. Left-Right, Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type 1.0 tributary width 1.0 tributary area <br /> Values from table 4.3A of the AF&PA SDPWS-2008 2.0 total width 2.0 total area <br /> ROOF Resisting Dead Load Tributary Width(Lower Floor) Tributary Area(Lower Floor) <br /> (e.g.Roof,Upper Floor,Main Floor) tributary width tributary area <br /> 16.50 ft Total Length of Shearwalls total width total area <br /> V(from upper)= 4217 lb 6227 lb hearwall= 8.0 ft Weight of Shearwall= 10.0 lbs <br /> V(from main)= 4003 lb 3483 lb _ all= 3.5 ft Tributary width for dead load= 2.0 ft <br /> V(from lower)= 0 lb 0 lb Aspect Rat!. - Length of adjoining wall= 4.0 ft <br /> E(Qry t)= 8,220 lb E(Eµx)= 9,711 lb Use alternate R factor for seismic? no <br /> V= 249 PLF V= 294 PLF <br /> AF&PA SDPWS-2008 (2w/h) x 0.93 x 510= 415 PLF USE <br /> Seismic controls sheaf.:% ii:a'?:;rg, <br /> CTOTAL= (floor above)+(this floor)= 1331 + 1993 lbs = 3324 lbs Wind controls <br /> TTOTAL= (floor above)+(this floor)= -1490 + 1666 lbs = 176 lbs Load case 8 controls-Wind <br /> Where overstrength factor is applicable,use this USE SIMPSON DESIGNED HOLDOWN: OK <br /> L value for E in equations 5,6,and 8: E= 2354 lbs <br />
The URL can be used to link to this page
Your browser does not support the video tag.