My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1622 E MARINE VIEW DR WHOLE SITE 2022-02-01
>
Address Records
>
E MARINE VIEW DR
>
1622
>
WHOLE SITE
>
1622 E MARINE VIEW DR WHOLE SITE 2022-02-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2022 2:59:04 PM
Creation date
5/5/2021 11:01:10 AM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
1622
Tenant Name
WHOLE SITE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
932
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fire alarm systems shall be installed under permit of the City of Everett Engineering & Public Services <br />Department. Electrical inspections and approval are required prior to calling for acceptance tests. Call <br />(425) 257-8810 for permit information. <br />The absence of monitoring for the alarm system will be cause for postponing Fire Department <br />inspection and testing and shall result in denial of occupancy. <br />A copy of NFPA 72 Record of Completion form must be filled out prior to final occupancy (NFPA 72, <br />2013 Edition, Chapter 7, pages 107-147). 2015 IFC, 907.7.2 <br />Call for design requirements per Authority Having Jurisdiction. <br />Automatic smoke detection is required. <br />Buildings with 13R sprinkler systems require attic heat detectors on alarm system <br />11. For buildings with two or more floors, including sub -floors, the alarm system must call point -by -point <br />reporting to an alarm center. <br />12. Fire Suppression (Sprinkler) System - An approved automatic suppression system shall be provided as <br />required by City Ordinance No. 3021-07, EMC, Chapter 16.76. <br />Plans for any such system shall be submitted to the Engineering & Public Services Department for <br />examination and approval. Such plans shall include plans for the underground mains that will supply <br />the sprinkler system. <br />The type of sprinkler to be installed will be determined by the ,Building Official. It may be an NFPA 13, <br />NFPA 13R, or NFPA 13D system depending upon several factors. Sprinkler installation shall not begin <br />without an approved and stamped set of plans from the Engineering & Public Services Department. <br />The Fire Department will also review the plans and shall field inspect the installation based only on <br />approved plans that must be on site. Changes to plans must be approved by both the Engineering & <br />Public Services and Fire Departments. <br />Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br />Underground piping shall be hydrostatically tested and flushed as established in NFPA Standard 24 for <br />private fire mains. (Below -ground piping must be installed by Washington State Licensed <br />Underground Sprinkler line certified "U" installers. For further information, contact the State Fire <br />Marshal's Office at (360) 596-3900 or contact the Everett Fire Department at (425) 257-8104.) All <br />such tests shall be witnessed by a Fire Department inspector. Call (425) 257-8104 or (425) 257-8120 to <br />make an appointment for inspection. <br />Contractors' materials and test certificates shall be submitted to the Everett Fire Department prior to <br />issuance of any Certificates of Occupancy. 2015 IFC, WA State Amendment 903.3.5.3, Page 111. <br />Call (425) 257-8104 for more information. l <br />�12�� <br />City of Everett — Community, Planning and Economic Development <br />Final MDNS SEPA #17-019 <br />
The URL can be used to link to this page
Your browser does not support the video tag.