<br />PTN. OF SE 1/4 OF SEC. 17, TWP 29., R5E W.M.
<br />LEGEND
<br />\ \ \ - - -s WATER METER AND SERVICE LINE
<br />N42'05'13"IY 25.27' FIRE DEPT. COVI (FDC)
<br />N8800'16V 5276
<br />1 —F— FIRE SERVICE
<br />OR pp 044 F. 6 E Z 6•
<br />— -- ,._..: _. _ _ `i •��'- S, `.,, STORM DRAIN
<br />W �' W42.0455W 51.54'
<br />SO CATCH BASIN
<br />15+� 16TH TREE'l \'� °� — — � _
<br />.,.0 +57 SS- SANITARY SEWER MAIN
<br />N68'3849"W 11.18'
<br />SS -- � _2 � ± i`` � STD. PRECAST MANHOLE
<br />`.�.. I ..— — — — — — — SIDE SEWER SERVICE
<br />v �
<br />_0 SIDE SEWER CLEANOUT
<br />1 EXIST. FIRE —W — WATER MAIN
<br />HYDRANT (TYP.) — — — — — — — WATER SERVICE
<br />---------------- -`
<br />PUBLIC U71UTY ESUT.
<br />V� N • �� \I FIRE HYDRANT (FH)
<br />7 BLDG70+42.88, 3500' RT I G G G G \`.� \( ';.�� ^ �N427)455"W 732.02' DOMESTIC BACKFLOW ASSEMBLY (DCVA)
<br />DRIVE G —
<br />IC l �`` 1 •ESMi. \
<br />V\ G G U G DID A\ \/ REC
<br />STA 70+32.97, 38.00' RT1
<br />rf i
<br />23+23.24, 1.00' RT " — _ STA 24+39 22, 1.00' RT !
<br />x45• BEND, MJ
<br />THRUST BLOCK I ! E STA 24+49.12, 0.83' RT
<br />(1)8 x45• BEND, MJ \ \
<br />22+86.23, 3.79' RT I �— — ._ — 1 _ — I ` L (1) THRUST BLOCK
<br />x45• BEND, MJ 24+
<br />THRUST BLOCK f ,I o
<br />f�Fe�i--------
<br />IOLF 8" DI �\ STA 25+2861, 18.50' LT
<br />,SS\•1` 0 0 BLDG.A
<br />G � D �i� `
<br />STA 22"+39.52
<br />(1) 5Y" FH ASSEMBLY it ._ -- I ;.8 10' • " �\ \•
<br />w1AINT \ > \'
<br />(1) THRUST BLOCK i/ BLDG /
<br />22LF 6" DI SPOOLPATIO
<br />` lbb — 4 5 STA 24+10.33, 1.00' Ri 11 BASKETBALL
<br />m I _ IL; (II DI TEE, FL COURT � \ . „ 4 / •�
<br />(1) 5%4 FH ASSEMBLY
<br />3 ,I (2) 8" DI GV, MJxFL \ 7i a �/ ( � STA 254-80.79, 46.60' LT
<br />(1) 774RUST BLOCK —IT \ � j 2
<br />o I 55LF T, DSPOOL AREA '.
<br />PLAY
<br />_ c i
<br />:T,:/
<br />25+09.88, 39.00 r 1
<br />#
<br />I
<br />-45- I I ! \
<br />I � G
<br />1 I c� I III � , • \ . * 6BQ/PA77 ,#? � .. Gj
<br />SEE C4,03 4 STA 25+77.79, 6.00' RT
<br />PR07ECT EXIST. STA 120+40.53 0.00' T
<br />FIRE HYDRANT 311F 8" DI (1) 8 x45' BEND (MJ) SEE 04.03
<br />STA 120+10.00, 0.00' T mY (1) THRUST BLOCK i CY ' 3 I =lid
<br />11 1 8 DI TAPPING TEE, MJxfL --
<br />(1) 8" D1 GV, FLxMJ 00 1" 2 STA 121+72+12, 0.00' T ➢' i U
<br />(1) THRUST BLOCK _ __ 7`' - j (1) 8"x45• BEND, MJ ( cJ I I•.
<br />. TO EXIST. - (1) THRUST BLOCK
<br />CONN
<br />SEE N07E 6 EXIST.
<br />I
<br />Xl L2" PE. WATE _ I I I AP,PbX. GRADING
<br />I
<br />ua-E. -. 12 1 �VMIT (TO) �
<br />SS of
<br />CONIC STRIP : 3 I - - _ �I 1 - �3_� `_r� /_ _ O 3 I iI• -
<br />�'
<br />(_
<br />i I ern IN W U a
<br />0
<br />SO - �� l-- --.- -
<br />' SD
<br />_GIs✓ ___� _ •
<br />13
<br />L— a— ------------------------ SEEC4.03 -----�
<br />SCALE. AS NOTED
<br />SEE PROFILE ON C4.11
<br />CONSTRUCTION NOTES
<br />o a
<br />O1 1" WATER SERVICE AND METER PER COE STD.
<br />m
<br />0 U U
<br />DWG. 501 w/ 1" BACKFLOW ASSEMBLY (DCVA)
<br />PER COE S7D. DWG. 520
<br />O2" WATER SERVICE AND METER PER COE STD.
<br />DWG. 502 w/ 2" BACKFLOW ASSEMBLY (DCVA)
<br />PER COE STD. DWG. 520
<br />J
<br />ODOUBLE CHECK DETECTOR VALVE ASSEMBLY
<br />o
<br />(DCDA) VAULT PER COE STD. DWG. 515, SEE
<br />C p o
<br />FIRE SYSTEM NOTE 3
<br />O2" FIRE SERVICE SUPPLY LINE (SEE FIRE
<br />4
<br />z
<br />z
<br />SYSTEM NOTES)
<br />Z
<br />V5
<br />" 3
<br />OFIRE HYDRANT ASSEMBLY PER COE STD. DWG.
<br />5
<br />507, APPROX. 6" DI LENGTH PER PLAN
<br />O POST INDICATOR VALVE (PIV), SEE FIRE SYSTEM
<br />o,
<br />NOTE .3
<br />a
<br />R
<br />O FIRE DEPARTMENT CONN. (FDC)
<br />o
<br />\
<br />z
<br />4
<br />80 i" IRRIGA77ON METERED WATER SERVICE PER
<br />COE STD. DWG. 501 w/ 1" BACKFLOW ASSEMBLY
<br />(DCVA) PER COE STD. OW. 520. CONTRACTOR
<br />TO INSTALL
<br />O9 PUBLIC UTILITY EASEMENT
<br />)0 3" FIRE SERVICE SUPPLY LINE (SEE FIRE
<br />r
<br />SYSTEM NOTES)
<br />54
<br />POTHOLE EXIST WATER MAIN TO VERIFY
<br />11
<br />+
<br />s
<br />LOCATION OF 8" SEGMENT
<br />,
<br />12 SAWCUT, REMOVE AND REPLACE EXIST T. PVM
<br />13 BLOW OFF ASSEMBLY PER COE STD. DWG. 511
<br />z
<br />0
<br />x
<br />a
<br />3
<br />z
<br />f ^ o
<br />3. DOMESTIC WATER SERVICE SUPPLY SHALL INCLUDE A DOUBLE v J �
<br />CHECK VALVE ASSEMBLY (DCVA) INSIDE BUILDING MECHANICAL m
<br />ROOM W/MATERIALS AND CLEARANCES PER COE STD. DWG.
<br />0
<br />520, REF. PROJECT PLUMBING PLANS/DETAILS. Z
<br />0
<br />4. THE CONTRACTOR SHALL VERIFY ALL SANITARY SEWER, w
<br />DOMESTIC WATER, AND FIRE SERVICE CONNECTIONS SHOWN ON \G
<br />THIS PLAN WITH THE INFORMATION PROVIDED IN THE PROJECT
<br />PLUMBING AND FIRE SPRINKLER PLANS/DETAILS AND N071FY
<br />ENGINEER OF ANY VARIANCES PRIOR TO CONSTRUCTION.
<br />5. ALL WATER MAIN PIPES SHALL BE DUCTILE IRON, CLASS 52 Q
<br />WITH A MINIMUM COVER OF 36" UNLESS OTHERWISE NOTED a- LU
<br />AND APPROVED BY THE CITY.
<br />6. COE WATER DEPT. CREWS SHALL MAKE ALL CONNECTIONS TO U)
<br />ACTIVE PUBLIC WATER MAINS UNDER SEPARATE U71UTY PERMIT `S
<br />CONNECTION FEE SHALL BE BASED ON A COST ESTIMATE BY
<br />THE WATER DEPT. AND WORK SHALL BE AT OWNERS EXPENSE. Lj,J Z
<br />FIRE SYSTEM N07ES a
<br />1. FIRE SERVICE SUPPLY LINE SIZES SHOWN ARE APPROXIMATE w J
<br />ACTUAL LINE SIZES SHALL BE PER FIRE PROTEC77ON ENGINEER. m
<br />2. COE UTILITY SERVICES DEPARTMENT SHALL HAVE ACCESS TO :D
<br />MECHANICAL ROOMS DURING THE HOURS OF 7:30AM TO cj- o
<br />4: OOPM, MONDAY THROUGH FRIDAY.
<br />3. FIRE SERVICE SUPPLY FOR THE BUILDINGS A. B, & F, G, AND
<br />J SHALL INCLUDE A DOUBLE CHECK DETECTOR ASSEMBLY CLIENT
<br />(DCDA) INSIDE BUILDING MECHANICAL ROOM PER COE STD.
<br />DWG. 523 FIRE SERVICE SUPPLY FOR BUILDINGS C, D, AND H
<br />SHALL INCLUDE A DCDA IN AN EXTERIOR VAULT PER COE STD. RIVERVIEW I, LLC
<br />DWG. 515. POST INDICATOR VALVE (PIV) AND FIRE 10900 NE 8TH STREET
<br />DEPARTMENT CONNECTION (FDC) FOR BUILDING J SHALL SUITE 1200
<br />CONNECT TO FIRE SUPPLY SERVICE UNE DOWNSTREAM OF BELLEVUE, WA 98004
<br />DCDA. ONE-WAY CHECK VALVE FOR FDC SERVICE SHALL BE PHONE.(425) 453-9551
<br />INSTALLED INSIDE VAULT OR MECHANICAL ROOM. ALL FIRE
<br />SPRINKLER SUPPLY LINES AND APPURTENANCES SHALL BE
<br />INSTALLED PER SEC71ON 5-17 OF COE DESIGN AND
<br />CONSTRUC77ON STANDARDS AND SPECIFICATIONS FIRE
<br />. 'SPRINKLER SYSTEM DESIGN AND CONNECTION DETAILS SHALL
<br />BE PROVIDED AND APPROVED UNDER SEPARATE PLUMBING
<br />PERMITcp�
<br />CONSULTANTS
<br />Srte Planning • W Engineering
<br />Land Use CDMIling • Project Management
<br />nQiws-86NF.B m
<br />9M,an8.w498052
<br />11-1425) 2%23901 FNe (425)2852389
<br />....cp Erna.....ntl....
<br />• PROJECT NO.
<br />0024-17-037
<br />DRAWING
<br />C4.04
<br />0 30 60 Know wbars below,
<br />Call before you dig, sNEEr 31 OP 47
<br />PLAN IN FEET owr.9mo 2ois cmrr,n�m.uc az,�onm.
<br />NOTES:
<br />1. ALL WATER VALVES SHALL BE PROVIDED W17H VALVE BOX AND
<br />OPERA77NG NUT EXTENDED PER COE STD. DWG. 505.
<br />2. MEGA LUGS SHALL BE INSTALLED AT ALL BENDS AND FITTINGS
<br />IN ACCORDANCE WITH COE STANDARDS ALL PIPES AND
<br />FIT77NGS SHOWN AS RESTRAINED JOINTS (li SHALL BE
<br />MEGALUG GASKET OR APPROVED EQUAL