Laserfiche WebLink
S F <br />8"/12" <br />D <br />8"/12 <br />12, 8/ <br />." . <br />LJ LJ LJ <br />ZD <br />! <br />�F <br />MAINTENANCE ROOF <br />VENT CAP FOR HATCH W/LADDER <br />UP SAFETY DEVICES - <br />LAUNDRY FANS, TYP. <br />LOCATE IN FIELD. <br />VENT CAP FOR RANGE <br />VENT CAPS FOR HOOD FANS TYP. <br />BATH, TYP. LOCATE INFIELD. <br />LOCATE IN FIELD. -' <br />1-HR RATED <br />ATTIC ACCESS <br />PANEL <br />I <br />I <br />I <br />RIDGE VENT,TYP. <br />I <br />I- <br />ATTIC #1 <br />_ -- -_-_-_-- -_- <br />A <br />L <br />V.1 <br />8" 1 12" <br />�t <br />1" / 12" <br />i <br />- -- <br />--- <br />-- °S <br />L-I <br />ICE & WATER SHIELD, TYP. <br />EXTEND 24" BEYOND FACE <br />OF EXTERIOR WALL. SEE <br />3/BE4.0 <br />Z DS <br />DS 9�17' 8" / 12" <br />- LJL J r-J <br />1 LJ <br />NT VENT CAP FOR <br />LAUNDRY FANS, TYP. <br />LOCATE IN FIELD. <br />L A <br />I <br />I <br />-VENT CAP FOR RANGE <br />VENT CAP FOR RANGE- <br />I- <br />HOOD FANS, TYP. <br />p <br />HOOD FANS, TYP. <br />LOCATE IN FIELD.- <br />N <br />LOCATE IN FIELD. <br />1 F <br />ACCESS PA <br />L J <br />DRAFSTO 9/A501 _ <br />O <br />EIL <br />1 <br />RIDGE VENT,TYP. <br />�Y <br />VENT CAP FOR <br />LAUNDRY FANS, TYP. <br />-VENT CAPS FOR <br />I <br />LOCATE IN FIELD. <br />ATTIC g2 <br />ATTIC #3 BATH, TYP. <br />I <br />,- - --_ -- <br />- LOCATE IN FIELD. r <br />- <br />I <br />ViA L <br />I <br />I <br />L I <br />I <br />v� <br />n! <br />RIDGE VENT,TYP. <br />rr <br />r� <br />rT <br />rr <br />7-7 <br />8" / 12" <br />-� <br />8" / 12" <br />DS <br />DS <br />DS <br />,I 8" / 12" <br />/' - <br />6" / 12" <br />L <br />L 6" PREFINISHED ALUMINUM <br />K-STYLE GUTTERS, TYP. <br />COMPOSITION SHINGLE ROOFING <br />TO MEET ASTM D7158 CLASS G OR <br />H, OR ASTM D3161 CLASS F OVER <br />ONE LAYER OF UNDERLAYMENT, <br />TYR <br />3 <br />A410 <br />CUT 76k18" OPENING IN MAIN ROOF <br />SHEATHING TO ALLOW VENTING OF <br />I OVERFRAMED AREAS <br />I <br />DS <br />- <br />8" <br />e / 12" <br />e / 12', Of <br />a. 'Lrl� <br />r <br />r-I <br />J <br />LJ <br />LJ <br />LJ <br />'Iyp <br />�t2 <br />o1 <br />9� <br />D7 <br />I I ram- <br />VENT CAP FOR <br />II <br />LAUNDRY FANS, TYP. <br />VENT CAP FOR RANGE I <br />LOCATE IN FIELD. <br />J HOOD FANS, TYP. <br />VENT CAPS FOR <br />LOCATE IN FIELD. <br />BATH, TYP. <br />1-HR RATED ATTIC - I <br />LOCATE IN FIELD. <br />ACCES$PANEL <br />ACCESS P L <br />A-ESTO <br />9/ 01 <br />1 <br />I <br />RIDGE VEI T,TYP. <br />C *4 <br />L--1----1�-----------On <br />II I I <br />II a L <br />r <br />11 <br />LJ <br />LJ <br />8" /'12" <br />�}� <br />8..! 12.' <br />8" / 17, <br />8" / 12' <br />D: <br />BUILDING A - ROOF PLAN <br />1/8" = T-0" <br />110 /r( BUILDING A -FLOOR 4 <br />vs' = T-T <br />ATTIC VENTILATION CALCULATIONS <br />ATTIC AREA 1 & 4: 3SF) <br />CEILING ASSEMBLY AT AT BOTTOM <br />OMM CHORD OF ROOF TRUSSES INCLUDES <br />CLASS II VAPOR BARRIER. REQUIRED VENTILATION @ 11300 (IBC <br />SECTION 1203.2 EXCEPTION 2): 1183 S.I. (8.21 S.F.) <br />EAVE VENTILATION: 42.76 LF. (513 L.1.) <br />• BIRD BLOCKING WITH THREE T DIAMETER HOLES PER TRUSS <br />BAY W/ 1/8" MESH SCREEN 2.50 S.I..0174 S.F. NFA PER NOTCH. <br />SEE DIAGRAM 1/A501 3.75 S.I.(.026 S.F.) NET FREE AREA PER <br />LINEAL FOOT= 136.8 S.I. (0.95 S.F.) TOTAL. <br />CONTINUOUS SOFFIT VENTILATION: 21 LF. 252 L.I. <br />• STRIP VENT WITH Z' WIDE ON BALCONY CEILING WITH 1/8" MESH <br />SCREEN. NET FREE AREA PER LINEAL FOOT = 504 S.I. (3.5 S.F.) <br />CONTINUOUS RIDGE VENTILATION: 95 L.F. <br />• COR-A-VENT REVOLUTION @ 12 S.I. NET PER FT. = 95 FT • 12 <br />S.I./FT = 1,140 S.I. (7S2 S.F.) TOTAL <br />TOTAL PROVIDED VENTILATION: 136.8 S.1+504 S.1+ 1,140 S.I. = 1,780.8 S.I. <br />(12.37 S.F.) <br />• EAVE &SOFFIT VENTS:(136.8+ 50411,183)' 100=54.2% <br />• RIDGEVENTS(1,140/1608+25)*100=70.88% <br />VENTILATION ALSO MEETS IBC SECTION 1203.2 EXCEPTION 1 <br />ATTIC AREA 2 & 3: 300,456 S.1 (2,086.5 SF) <br />CEILING ASSEMBLY AT BOTTOM CHORD OF ROOF TRUSSES INCLUDES <br />CLASS II VAPOR BARRIER. REQUIRED VENTILATION @ 1/300 (IBC <br />SECTION 1203.2 EXCEPTION 2): 1001.5 S.I. (6.96 S.F.) <br />EAVE VENTILATION: STST LF. (694.5 L.I.) <br />• BIRD BLOCKING WITH THREE 2' DIAMETER HOLES PER TRUSS <br />BAY W/ 1/8" MESH SCREEN 2.50 S.I. (.0174 S.F.)NFA PER NOTCH. <br />SEE DIAGRAM 1/A501 3.75 S.I.(.026 S.F.) NET FREE AREA PER <br />UNEAL FOOT= 185.2 S.I. (1.29 S.F.) TOTAL. <br />CONTINUOUS SOFFIT VENTILATION: 21 LF. (252 L.I.) <br />• STRIP VENT WITH Z' WIDE ON BALCONY CERING WITH 1/8" <br />MESH SCREEN. NET FREE AREA PER UNEAL FOOT = 504 S.I. (3.5 <br />S.F.) <br />CONTINUOUS RIDGE VENTILATION. 62.75 LF. <br />• COR-A-VENT REVOLUTION @ 12 S.I. NET PER FT = 62.75 FT • 12 <br />S.UFT = 753 S.I. (5.23 S.F. TOTAL <br />TOTAL PROVIDED VENTILATION: 185.2 S 1 + 504 S.I + 753 S.I. = 1,442.2 S.I. <br />(10.02 S.F.) <br />EAVE & SOFFIT VENTS. (185.2+504/1,001.5)'100 68.82% <br />• RIDGE VENTS:(753/1,001.5)'100=75.2% <br />VENTILATION ALSO MEETS IBC SECTION 1203.2 EXCEPTION 1 <br />MR BARRIER <br />AIR BARRIER <br />INTERIOR <br />1. <br />SEAL ALL PENETRATIONS IN EXTERIOR <br />WALL INDICATED AS THE LINE OF THE <br />AIR BARRIER <br />2. <br />AT TOP FLOOR CEILING LID: SEAL FIRST <br />LAYER OF GWB TO TOP PLATE TO <br />PREVENT AIR LEAKAGE INTO ATTIC <br />SPACE <br />3. <br />SEALANY PENETRATIONS IN CEILING <br />LID TO PREVENT AIR LEAKAGE INTO <br />ATTIC SPACE <br />4. <br />AT DOUBLE STUD WALLS, SEAL TOP OF <br />STUDS AT ATTIC WITH SELF ADHERING <br />MEMBRANE <br />5. <br />SEAL BOTTOM PLATES TO FLOOR <br />SHEATHING, SILL PLATE TO FLOOR <br />SHEATHNG AND GWB TO SILL PLATE. <br />SEAL ANY PENETRATIONS IN DOUBLE <br />STUD WALL AT ALL FLOOR LEVELS <br />6. <br />AT TOP FLOOR CEILING SEAL ALL <br />PENETRATIONS. I.E. SPRINKLERS <br />EXTERIOR <br />1. <br />SEAL WATER RESISTANT BARRIER AT <br />TOP AND BOTTOM TERMINATIONS AND <br />TAPE ALL WATER RESISTANT BARRIER <br />LAPS. <br />2. <br />SEAL ALL PENETRATIONS SUCH AS <br />SPRINKLERS, FIRE EXTINGUISHER <br />BOXES, UGHT FIXTURES, ELECTRICAL <br />BOXES, ETC. <br />1. SEE STRUCTURAL DRAWINGS <br />FOR ROOF FRAMING. <br />JOHNSON BRAUND- <br />2. ALL ROOFING TO BE CLASS B <br />MINIMUM PER IBC SECTION 1505 <br />1520052nd Ave. South <br />AND TABLE 1505.1. <br />Suite 300 <br />3. ALL ROOF SLOPES ARE 5"/FT. <br />Seattle, WA 98188 <br />U.N.O <br />Phone 2D6.765.8300 <br />4. DRAFTSTOPS ARE REQUIRED IN <br />,-..johm-braund- <br />ATTICS OR OTHER CONCEALED <br />ARCHITECTURE <br />ROOF SPACES PER IBC SECTION <br />INTERIOR DESIGN <br />718.4.2. <br />Greg L. AIIW. AIA <br />5. PER IBC SECTION 708.4, IN <br />Jeffry A. Wili-, AIA <br />COMBUSTIBLE CONSTRUCTION <br />WHERE THE FIRE PARTITIONS ARE <br />NOT REQUIRED TO BE <br />CONTINUOUS TO THE SHEATHING, DECK <br />OR SLAB, THE SPACE BETWEEN THE <br />CEILING AND THE SHEATHING, DECK OR <br />SLAB ABOVE SHALL BE FIRE BLOCKED OR <br />DRAFTSTOPPED IN ACCORDANCE WITH IBC <br />SECTIONS 718.2 AND 718.3 AT THE <br />PARTITION LINE. <br />EXCEPTION #5: ATTIC FIRE LOCKING OR <br />DRAFTSTOPPING IS NOT REQUIRED AT THE <br />PARTITION LINE IN GROUP R-2 BUILDINGS <br />THAT DO NOT EXCEED FOUR STORIES <br />ABOVE GRADE PLANE, PROVIDED THE <br />ATTIC SPACE IS SUBDIVIDED BY <br />esss <br />1� I REGISTEREDITECT <br />DRAFTSTOPPING INTO AREAS NOT <br />EXCEEDING 3,000 SF OR ABOVE EVERY <br />, > ARCH <br />TWO DWELLING UNITS, WHICHEVER IS <br />SMALLER. <br />PFREY ARTHUR WILLIAM <br />6. DRAFTSTOPPING MATERIALS TO <br />s1a1E or wasrvlrvclory <br />BE J Z. GYP. SHEATHING OR 12" PLYWOOD <br />OR OSB SHEATHING PER IBC SECTION <br />718.3,1. <br />7. DRAFTSTOPPING SHALL BE <br />INSTALLED ABOVE AND IN LINE WITH <br />SLEEPING UNIT AND DWELLING UNIT <br />SEPARATION WALLS THAT DO NOT <br />EXTEND TO THE UNDERSIDE OF THE <br />ROOF SHEATHING ABOVE PER IBC <br />SECTION 718.4,2. <br />EXCEPTION #31 IN OCCUPANCIES IN <br />GROUP R-2 THAT DO NOT EXCEED FOUR <br />STORIES ABOVE GRADE PLANE, THE ATTIC <br />SPACE SHALL BE SUBDIVIDED BY <br />DRAFTSTOPS INTO AREAS NOT <br />3 <br />EXCEEDING 3,000 SF OR ABOVE EVERY <br />TWO DWELLING UNITS, WHICHEVER IS <br />a <br />SMALLER. <br />c <br />8. PER IBC SECTION 1203.2 EXCEPTION <br />THE NET FREE CROSS -VENTILATION AREA <br />SHALL BE PERMITTED TO BE REDUCED TO <br />Z <br />1/300PROVIDED BOTH OF THE FOLLOWING <br />CONDITIONS ARE MET: <br />1. IN CLIMATE ZONES 6, 7, AND 8, A CLASS I <br />OR II VAPOR RETARDER IS INSTALLED ON <br />THE WARM -IN -WINTER SIDE OF THE CEILING <br />2. AT LEAST 40 PERCENT AND NOT MORE <br />THAN 50 PERCENT OF THE REQUIRED <br />VENTING AREA IS PROVIDED BY <br />G =, <br />VENTILATORS LOCATED IN THE UPPER <br />PORTION OF THE ATTIC OR RAFTER SPACE. <br />UPPER VENTILATORS SHALL BE LOCATED <br />NOT MORE THAN 3 FEET BELOW THE RIDGE <br />OR HIGHEST POINT OF THE SPACE, <br />MEASURED VERTICALLY, WITH THE BALANC <br />am, <br />OF THE VENTILATIO NPROVIDED BY EAVE Of <br />CORNICE VENTS. WHERE THE LOCATION O <br />ISSUE DATE 7/19119 <br />- <br />WALL OR ROOF FRAMING MEMBERS <br />CONFLICTS WITH THE INSTALLATION OF <br />UPPER VENTILATORS, INSTALLATION MORE <br />THAN 3 FEET BELOW THE RIDGE OR <br />HIGHEST POINT OF THE SPACE SHALL BE <br />PERMITTED. <br />9. BATHROOMS SHALL BE <br />MECHANICALLY VENTILATED IN <br />ACCORDANCE WITH THE IMC PER <br />IBC SECTION 1203.5.2.1. <br />PLAN NOTES <br />1. SEE SHEET A040, A041 SHEETS <br />FOR FIRE.RESISTIVE ASSEMBLIES <br />ASSEMBLY TAG <br />2. SEE ENLARGED UNIT PLAN <br />SHEETS FOR INTERIOR <br />DIMENSIONS, WINDOW AND DOOR <br />CALLOUTS, AND LOCATION OF <br />RATED WALLS. <br />3. RECESSED/1-HOUR FIRE <br />EXTINGUISHER - SEE SHEET F.E.C. <br />A030, LOCATE PER IFC <br />TYPE 5LB AC <br />SIZE 2A 10BC <br />4. * INDICATES TYPE <br />ACCESSIBLE UNIT. ALL REMAINING <br />UNITS ON FIRST FLOOR SHALL MEET <br />TYPE B ACCESSIBLE UNIT CRITERIA <br />PER IBC SECTION 1107.6.2. <br />5. REFER TO ACCESSIBILITY NOTES <br />ON SHEET CSGD. <br />6 REFER TO DESIGWBUILD <br />PLUMBING PLANS. <br />7 REFER TO DESIGWBUILD <br />ELECTRICAL PLANS, <br />8 REFER TO SHEET A030 FOR <br />PENETRATION REQUIREMENTS IN <br />FIRE RATED CONSTRUCTION. <br />g LEVELS 1 -4 CONSTRUCTION TYPE VA, <br />OCCUPANCIES R-2 <br />10 ALL LEVELS FULLY SPRINKLERED PER <br />IBC SECTION 903.3.1.2 (NFPA 13R). <br />11. REFER TO CS SHEETS FOR FIRE <br />ASSEMBLY KEY PLAN W/WALL TYPE <br />TAGS & LOCATIONS. REFER TO SHEET <br />SERIES A040, A041 FOR ASSEMBLY <br />DETAILS. <br />12. UNIT DEMISING WALLS ARE 1-HOUR <br />RATED PER IBC SECTION 708 W/ <br />MINIMUM STC 50. <br />13. DIMENSIONS ARE TO OUTSIDE EDGE OF <br />CONCRETE OR FACE OF STUD, TYP. <br />14. FSR: FIRE SPRINKLER RISER ROOM: <br />FIRE SPRINKLER & FIRE ALARM PANEL <br />ROOMS SHALL BE MARKED WITH A <br />PLAINLY VISIBLE AND LEGIBLE SIGN <br />STATING SPRINKLER RISER ROOM <br />AND/OR F.AC.P OR SIMILAR APPROVED <br />WORDING. <br />PROJECT#. 1705 <br />DRAWN BY: AT <br />CHECKED BY: ST <br />BUILDING PLANS - <br />FLOOR 4 AND ROOF - <br />BLDG A <br />A210 C <br />BID / CONSTRUCTION <br />