Laserfiche WebLink
GENERAL UNIT PLAN NOTES <br /> 0 tiv <br /> 1. LEVELS 1-4:TYPE V-A <br /> ALL LEVELS FULLY SPRINKLERED PER NFPAI3R. JOHNSON BRAU N Duo <br /> 2. SEE SHEETS A040-041 FOR FIRE-RESISTIVE ASSEMBLY TYPES 15200 52nd Ave.South <br /> TYPICAL WALL TYPES: Suite 300 <br /> LEVELS 1 TO 4-TYPE V-A CONSTRUCTION Seattle,WA 98188 <br /> Phone 206.766.8300 <br /> 7H <br /> LL BREEZE WAY „.w,.lonosontrouaa.00m <br /> 3'-8 1/27A EXTERIOR WALL <br /> VERIFYFY ®off 10 � ARCHITECTURE <br /> A55030._0.. INTERIOR DESIGN <br /> 212„/ / 7D UNIT DEMISING WALLS <br /> l 10'-41/2" 2'-31/2" 9'-0" / 8'-2" / Greg L.Allxine,AM <br /> •V f 7B INTERIOR WALL(NON-LOAD BEARING) Jeffrey A.Williams,AM <br /> ,,, • \ - TYP.m` :\ \ \ \ HE INTERIOR WALL(LOAD BEARING) <br /> r 411 <br /> - 5 ;� g „ aiL ,..,- <br /> OD-4!) 3. REFER TO OWNER PROVIDED FINISH&FIXTURE SCHEDULES. <br /> p111 RANGE REF <br /> rt <br /> I 6 CD 4 • m 2 4. OX DOOR TYPE-SEE DOOR SCHEDULE ON SHEET A100 <br /> 4 ••Q - Z <br /> '� 0 BATH .$ El 6- m ODINING 5. ,O. WINDOW TYPE-SEE UNIT WINDOW SCHEDULE ON SHEET A100 <br /> 6. ALL UNITS ON STORIES THAT ARE NOT ACCESSIBLE TO BE TYPICAL UNITS.SEE <br /> �' ___, r-3 -1 } r FLOOR PLANS FOR LOCATIONS.SEE UNIT SHEETS FOR TYPICAL UNIT PLANS. <br /> 3_• \}//-,\-,I/ ALL UNITS ON AN ACCESSIBLE STORY SHALL COMPLY WITH WASHINGTON STATE <br /> Z -. (:-... a V V'l I -,� DW ^ ®� (ICC/ANSI 117.1)'TYPE B".SEE FLOOR PLANS FOR LOCATIONS. (�ass6 <br /> > l - FIVE PERCENT OF TOTAL NUMBER OF UNITS ARE DESIGNATED AS"TYPE A"UNITS. 1 \ 'REGISTERED <br /> N ,Y FX- m\ \ I SEE SHEET A010 FOR TYPE A CALCULATION.SEE FLOOR PLANS FOR LOCATIONS. 1 / RCHITECT <br /> z wIPli <br /> 5-4 SEE UNIT SHEETS FOR"TYPE A"AND"TPPEB"UNIT PLANS. <br /> (7 SEE ACCESSIBILITY NOTES SHEET CS00< ll ;_`e 54"HIGH WING WALL 2X4 Oj SEE SHEET A660 FOR ACCESSIBLE DETAILS FFREY ARTHUR WILLIA51 <br /> APOST STATE Of WASHINGTON <br /> CARPET `*IVINYL 7. COORDINATE W/DESIGN/BUILD ELECTRICAL&MECHANICAL' <br /> \ <br /> 2 O- I i Z - Q HARDWIRED SMOKE/CO DETECTOR W/BATTERY BACK-UP <br /> ---- 1•• V -IN ER 0 NE TES W THI EACH UNIT P R I:C EC 10 907.2.11.5 A <br /> / ? 7 <br /> I i - WX m\ EXHAUST FAN rj DRYER VENT <br /> ,}' 3'_6" / 6 ElWHOLE HOUSE FAN PER IMC REQUIREMENTS <br /> in <br /> 12xie VENT ABOVE DOUBLE DOOR <br /> 7 O POWER VENT WILL BE REQUIRED FOR DRYER <br /> / 6'-3" - 6'-T' - " EXHAUST LENGTHS THAT EXCEED MANUFACTURER'S <br /> SPECIFICATIONS.COORDINATE DESIGN/BUILD <br /> MECHANICAL. <br /> -_ 8. INDICATES LOCATION OF EXHAUST DUCTING AI <br /> • <br /> BEDROOM LIVING FOR DUCTS WITHIN JOIST SPACE-SEE DETAIL A030 <br /> j VENT THROUGH ROOF @ 4TH FLOOR ,... <br /> 9. INDICATES LOCATION OF DROPPED SOFFIT ® 3 <br /> r <br /> TYP. 78 TYP. i ���������@ 7•-0"MIN.SEE DETAIL <br /> 10. ALL EXHAUST VENT TERMINATIONS MUST BE 3 FEET CLEAR FROM ANY o <br /> OPERABLE OPENING INTO THE BUILDING,AND 10 FEET CLEAR FROM <br /> ANY MECHANICAL AR INTAKE.GANG TERMINATIONS TOGETHER UNDER 11 <br /> ONE SHROUD,AS POSSIBLE. <br /> 11. DIMENSIONS ARE TO FACE OF STUD <br /> I _ \ UNLESS NOTED OTHERWISE. '0 <br /> 3'-0" O 7A T,P A '�' ® - UNE OF AR 12. FOR TYPICAL PLUMBING INSULATION,SEE DETAIL P o <br /> BARRIER <br /> kr MIN. i <br /> CONTINUITY 13. REQUIRED CLEAR FLOOR SPACES AS SHOWN ON PLANS:REFER <br /> DECK 0 STOo AT STORAGE ALSO TOACCESSIBIUTY NOTES SHEETS CS00- m <br /> 1O / 6'-21f4" 13'-83/4" `� 7A in <br /> y <br /> rbin N �j 30'X48"CLR.FLOOR SPACE AT FIXTURES&APPUANCES o a <br /> \ \ /i* "• \ \ L_--J (C�TH ERED)&ONE AREA FREE OF DOOR SWING IN <br /> L- e L---I-, 48"X48"CLR.FLOOR SPACE AT ENTRY DOOR PUSH SIDE-ALL a <br /> 8 <br /> UNITS w <br /> / / / I I 54"X60'CLR.FLOOR SPACE AT PULL SIDE OF ALL PASSAGE ISSUE DATE: 7/19/19 <br /> 1/2" 30'-0" EDGE OF DECK L---IJ DOORS-TYPE A UNIT ONLY <br /> 4 / <br /> , <br /> CL GUARDRAIL @ 42"A.F.F. / \ <br /> I <br /> ) / 60"MANEUVERING CIRCLE-TYPE A UNITS ONLY <br /> UNIT PLAN 1.1 <br /> \_ i <br /> LEVEL 2-4 <br /> 14. CONTROLS,FAN WALL SWITCH&OUTLETS TO BE WITHIN REAC m <br /> RANGES-SEE ACCESSIBILITY NOTES SHEET CSOO&DETAIL ligig <br /> 15. FOR TUBS AT FIRE-RATED WALL AND FLOOR ASSEMBLIES-SEE m MI <br /> A030 A030 <br /> 16. ELECTRICAL PANEL m <br /> EE 17. S&P=SHELF&POLE.CLOSET SHELF&POLE IN TYPE A UNITS TO BE S <br /> ADJUSTABLE TO BE WITHIN REACH RANGE 48"MAX AFF. <br /> ULi <br /> 18. 0 WATER HEATER.SEE DETAIL m <br /> m ® m <br /> o UNIT INTERIOR ELEVATION NOTES <br /> IS <br /> 1. DIMENSIONS ARE TO FACE OF G.W.B(NET),UNLESS NOTED OTHERWISE. 3 <br /> 2. FIELD VERIFY ALL FINISHED DIMENSION PRIOR TO ORDERING CABINETS& <br /> L COUNTERTOPS. <br /> 3. PROVIDE BLOCKING AT TOILET PAPER HOLDERS,TOWEL BARS,DOOR STRIKES, .00 <br /> O. DRAPERIES,REMOVABLE CABINET SUPPORTS&GRAB BARS. N <br /> C oFa <br /> I M KITCHEN KEYNOTES BATH KEYNOTES d 5 g <br /> Csla7 <br /> Obi K1 CONCEAL DUCT AT RANGE HOOD b1 ACCESSIBLE LAY.SINK AND m tpQa '' <br /> EXHAUST,SEE UNIT PLANS FOR COUNTER-TYPE A&B <br /> �3 Fo <br /> B EXTENT OF DROPPED SOFFIT. UNITS-SEE <br /> yk PS <br /> O OPEN KNEE SPACE FOR w <br /> m CABINETS W/ADJUSTABLE SHELVES VANITY SINK AT ALL ® ,I0: oB <br /> 3 @ <br /> PER FINISH SCHEDULE. ACCESSIBLE BATHROOMS IN Q ••- g Y g°wB <br /> w TYPE A UNITS.EXTEND �w ,� <br /> d OK3 COUNTERTOP&BACKSPLASH PER FLOORING UNDER-SEE h go <br /> OWNER SPECIFICATIONS. 6g PROVIDE GRAB BARS © d w A In o LL <br /> i ADAPTABLE FEATURE FOR ` o U to ,rn B i <br /> ACCESSIBLE WATERCLOSET •r 4 a t,,‘.9 m o <br /> 0 @ TYPE B UNITS,AND ® ` man 3 H <br /> 0 ,7 ADA COMPUANT FAUCET W/LEVER INSTALL GRAB BAR @ TYPE PM w a 8 z o w <br /> HANDLE(ALL UNITS) AUNITS-SEE B BARS AI ._/ aO W w Ery tl15 <br /> / © ®LEVELS 2-0 ® VW REMOVABLE CABINET(ADAPTABLE O PROVIDE <br /> BLERFEATURE FOR Y. o_ O m a o <br /> 21" 30" 18" 33" O FEATURE)@OPEN KNEE SPACE FOR I� <br /> . U ala 39" FILLER �l�(I� FILLER K6 SINK AND LOWERED WORKSPACE @ UNITS AND INSTALL GRABS al. <br /> z <br /> © } ( ©" Pi <br /> _0 <br /> NEESPACE-EXTENDF OOINGIN BAR @TYPE AUNITS-SEE <br /> UNDER 0 MIRROR-40"AF.F.MAXTOPROJECT#. 1705 <br /> C ® OPEN ® 1. O (TYPE A ACCESSIBLE UNITS ONLY) BOTTOM EDGE OF pRgWN BY: AF <br /> N <br /> I MI <br /> O. <br /> REFLECTING SURFACE. <br /> K7 BLIND CORNER CABINET CHECKED BY: ST <br /> O _ ® ® O SURFACE MOUNTED LIGHT <br /> moris <br /> E I;L = 1 m _� �tl EF SPECIFICATIONOD PER OWNERO TION ONE BEDROOM UNIT <br /> iffuNimil <br /> KBMICROWAVE&HOl 0 �� �1 R RANGE W/FRONT CONTROLS b7TUB&SURROUNDPERERSPECIFICAU `= = m1ol l J _-b7-- m m L_J Ks O PLANS-TYPICAL <br /> m <br /> _1 (TYPE A ACCESSIBLE UNITS ONLY) b8 WIRE SHELVING <br /> �� if �k ! ' ® RANGE HOOD ONLY.PROVIDE WALL O PLASTIC LAMINATE <br /> I,17" 24" 33" 30" 15" A 21" 30" TB" I SWITCH AT 46"MAX AFF.PROVIDE COUNTERTOP& <br /> v �� 'I FILLER -�'t•77RII�i•� COUNTERTOP MICROWAVE(TYPE A BACKSPLASH PER OWNER <br /> / ° I BATHROOM ��BATHROOM BATHROOM 3 TCHFN © ACCESSIBLE UNITS ONLY) SPECIFICATION. <br /> w 1/4"=1'0" 1/4"-1'-0" 1/4"=1'-0' 1/4"-1'.D ADA COMPUANT'REFRIGERATOR QQQ Al 10 <br /> Y 11 10 VSPEC FICATION?f� <br /> z MAX 54"Hi.AFF TO FREEZER iJ\\ <br /> BID/CONSTRUCTION <br />