Laserfiche WebLink
c <br />(/ <br />WATER/FIF <br />DOGHOUS <br />E <br />I <br />m <br />PLAN NOTES <br />1. <br />SEE SHEET A040, A041 SHEETS <br />FOR FIRE -RESISTIVE ASSEMBLIES <br />ASSEMBLY TAG <br />2. <br />SEE ENLARGED UNIT PLAN <br />SHEETS FOR INTERIOR <br />DIMENSIONS, WINDOW AND DOOR <br />CALLOUTS, AND LOCATION OF <br />RATED WALLS. <br />3. <br />RECESSED/1-HOUR FIRE <br />EXTINGUISHER-SEESHEET FEC. <br />—� <br />A030, LOCATE PER IFC <br />TYPE 51 AC <br />SIZE 2A 10SC <br />4. <br />pIL� <br />�'" INDICATES TYPE <br />ACCESSIBLE UNIT. ALLREMAINING <br />UNITS ON FIRST FLOOR SHALL MEET <br />TYPE B ACCESSIBLE UNIT CRITERIA <br />PER IBC SECTION 1107.6.2. <br />5. <br />REFER TO ACCESSIBILITY NOTES <br />ON SHEET CSOO. <br />REFER TO DESIGWBUILD <br />6 <br />PLUMBING PLANS. <br />7 <br />REFER TO DESIGWBUILD <br />ELECTRICAL PLANS. <br />8. <br />REFER TO SHEET A030 FOR <br />PENETRATION REQUIREMENTS IN <br />FIRE RATED CONSTRUCTION. <br />y <br />LEVELS 1 - 4 CONSTRUCTION TYPE VA, <br />OCCUPANCIES R-2 <br />10 <br />ALL LEVELS FULLY SPRINKLERED PER <br />IBC SECTION 903.3.1.2 (NFPA 13R). <br />11. <br />REFER TO CS SHEETS FOR FIRE <br />ASSEMBLY KEY PLAN W/ WALL TYPE <br />TAGS & LOCATIONS. REFER TO SHEET <br />SERIES A040, A041 FOR ASSEMBLY <br />DETAILS. <br />12. <br />UNIT DEMISING WALLS ARE 1-HOUR <br />RATED PER IBC SECTION 708 W/ <br />MINIMUM STC 50. <br />13. <br />DIMENSIONSARETO OUTSIDE EDGE OF <br />CONCRETE OR FACE OF STUD, TYP. <br />14. <br />FSR: FIRE SPRINKLER RISER ROOM: <br />FIRE SPRINKLER & FIRE ALARM PANEL <br />ROOMS SHALL BE MARKED WITH A <br />PLAINLY VISIBLE AND LEGIBLE SIGN <br />STATING SPRINKLER RISER ROOM <br />AND/OR F.A.C.P OR SIMILAR APPROVED <br />WORDING. <br />AIR BARRIER <br />INTERIOR <br />1. <br />SEAL ALL PENETRATIONS IN EXTERIOR <br />WALL INDICATED AS THE LINE OF THE <br />AIR BARRIER <br />2. <br />AT TOP FLOOR CEILING LID: SEAL FIRST <br />LAYER OF GWB TO TOP PLATE TO <br />PREVENT AIR LEAKAGE INTO ATTIC <br />SPACE <br />3. <br />SEALANY PENETRATIONS IN CEILING <br />LID TO PREVENT AIR LEAKAGE INTO <br />ATTIC SPACE <br />4, <br />AT DOUBLE STUD WALLS, SEAL TOP OF <br />STUDS AT ATTIC WITH SELF ADHERING <br />MEMBRANE <br />5. <br />SEAL BOTTOM PLATES TO FLOOR <br />SHEATHING, SILL PLATE TO FLOOR <br />SHEATHING AND GWB TO SILL PLATE. <br />SEALANY PENETRATIONS IN DOUBLE <br />STUD WALL AT ALL FLOOR LEVELS <br />S. <br />AT TOP FLOOR CEILING SEAL ALL <br />PENETRATIONS. I.E. SPRINKLERS <br />EXTERIOR <br />1. <br />SEAL WATER RESISTANT BARRIER AT <br />TOP AND BOTTOM TERMINATIONS AND <br />TAPE ALL WATER RESISTANT BARRIER <br />JOHNSON BRAUND- <br />15200 52nd Ave. South <br />Suite 300 <br />Seattle, WA 98188 <br />Phone 206.766.8300 <br />vnxvlah... -auntl.— <br />ARCHITECTURE <br />INTERIOR DESIGN <br />Greg L. Nl-., AIA <br />Jeffrey A. WI1,a AIA <br />BS56 <br />REGISTERED <br />ARCHITECT <br />FFRRE ARTW R iWGiOiRM <br />I ISSUE DATE: 7119119 <br />LAPS. H <br />2. SEAL ALL PENETRATIONS SUCH AS o t <br />SPRINKLERS, FIRE EXTINGUISHER C 3 <br />BOXES, LIGHT FIXTURES, ELECTRICAL H <br />BOXES, ETC. <br />w <br />� s <br />�w m og <br />�,- <br />3 <br />U <br />J <br />l9mN ✓3,0 <br />0 !L <br />Q J �Qm uu <br />3 ,a <br />U <br />4)wdz <br />w o <br />' D S Lpo <br />R a o rc Imo <br />PROJECT#. 1705 <br />DRAWN BY: ALF <br />CHECKED BY: ST <br />BUILDING PLANS - <br />FOUNDATION AND <br />FLOOR 1 - BLDG E <br />A214A <br />BID / CONSTRUCTION <br />