My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1622 E MARINE VIEW DR BUILDING E 2022-08-29
>
Address Records
>
E MARINE VIEW DR
>
1622
>
BUILDING E
>
1622 E MARINE VIEW DR BUILDING E 2022-08-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2022 10:51:32 AM
Creation date
5/6/2021 7:49:47 AM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
1622
Tenant Name
BUILDING E
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
90
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Envelope⢠<br />2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Oct 2017 <br />Project Title: Riverview Apartments - BLDG E <br />Date 12/31/2018 <br />Vertical Fenestration and <br />Skylight Area Calculation <br />Total Vertical <br />Fenestration Area <br />(rough opening) <br />NET Exterior <br />Above Grade <br />Wall Area <br />Total Skylight Area <br />(rough opening) <br />NET Exterior Roof <br />Area <br />Prescriptive Path - Enter envelope sf values <br />directly into this section of ENV -SUM for <br />New <br />3,772 <br />18,012 <br />0 <br />11,140 <br />vertical fenestration, skylights, net walls and <br />roof. For Additions and Alterations, refer to <br />Existing <br />0 <br />0 <br />0 <br />0 <br />these sections in ENV -SUM for further <br />instructions. <br />Total <br />3,772 <br />18,012 <br />0 <br />11,140 <br />Component Performance - When this <br />Envelope Compliance Path is selected, write- <br />protection of this section is enabled. Enter <br />envelope sf values for all assemblies into the <br />ENV-UA form. Envelope information from <br />ENV-UA will auto -fill into this section of ENV - <br />Vertical <br />o <br />Fenestration -to- 17.3 /o <br />Wall Ratio (WWR) <br />Skylight -to -Roof <br />SRR <br />Ratio (SRR) <br />Vertical Fenestration Area Compliance <br />VERTICAL FENESTRATION AREA COMPLIES WITH MAXIMUM ALLOWANCE <br />Skylight Area Compliance <br />NO SKYLIGHT PROPOSED. COMPILIES WITH MAXIMUM ALLOWANCE. <br />Vertical Fenestration <br />Q High performance fenestration U-factors and SHGC per C402.4.1.3 <br />Alternates <br />Q Dedicated outdoor air system per C402.4.1.4 and C403.6 <br />Show locations of qualifying daylight zone Q In buildings >_ 3 stories, 25% or more of NET floor area is in DLZ per C402.4.1.1 <br />(DLZ) areas and ft2 on project plans. <br />Q In buildings < 3 stories, 50% or more of CONDITIONED floor area is within DLZ per C402.4.1.1 <br />For Daylight Zone Area Calculations- Daylight Zone Calculations <br />a) Sidelight areas include primary + <br />secondary daylight zone areas. Daylight Zone Fenestration Alternate Sidelight Daylight Toplight Daylight Percent Daylight <br />b) Include overlapping toplight and sidelight Not Selected. No Calculations Required Zone Area Zone Area Zone Area <br />daylight zone areas under Toplight. <br />c) Net floor area definition in Chapter 2. <br />Spaces in Single Story List all enclosed spaces that exceed 2,500 ftz have ceiling height greater than 15 ft, and are space <br />Building Requiring Skylights types required to comply with this provision. Indicate aperture with AP"prefix (AP 1.1966) <br />In these spaces a minimum of 50% of the Space Space Area (ft) DLZ Area (ft) SRR or Aperture Exception <br />floor area shall be within a skylight daylight <br />zone (DLZ). Refer to C402.4.2 for <br />requirements. <br />SRR = Skylight to roof ratio <br />Envelope Exemptions <br />Low Energy and Semi -heated <br />Spaces <br />Low energy spaces per C402.1.1 Item 1 are exempt from the thermal envelope provisions. Semi - <br />heated spaces heated by systems other than electric resistance are exempt from wall insulation <br />provision only per C402.1.1.1. <br />Complete Low Energy and Semi -Heated Spaces table in MECH-SUM to verify eligibility based on <br />installed peak heating and cooling capacity per sf. <br />Equipment Buildings <br />Wall Insulation <br />R-Value <br />Roof Insulation <br />R-Value <br />Overall Average <br />U-Factor <br />Equipment buildings are exempt from the <br />thermal envelope provisions per C402.1.2. <br />Equipment Building Envelope <br />Electronic equipment power (watts/sf) <br />The following shall be met to be eligible: <br />building sizes 500 sf, average wall/roof U- <br />factors U-0.20, electronic equipment load >_ <br />Heating system output capacity (Btu/hr) <br />7 watts/sf, heating system output capacity <_ <br />Cooling capacity (Yes/No) <br />17, 000 btu/h. Cooling system capacity not <br />limited. <br />
The URL can be used to link to this page
Your browser does not support the video tag.