sTnee-Tr s <br /> CITY OF EVERETT <br /> Public Works Department <br /> March 22, 2019 <br /> Seth Terry <br /> Johnson Braund, Inc. <br /> 15200 52nd Ave. South, Suite 300 <br /> Seattle, WA 98188 <br /> setht@johnsonbraund.com <br /> Owner: Riverview I, LLC <br /> Job Address: 1622 East Marine View Drive <br /> Plan Check No: B1812-032, Building G <br /> RE: Building Permit Review Letter <br /> Dear Mr. Terry, <br /> In response to the application for a building permit, the plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. <br /> NON STRUCTURAL <br /> General <br /> 1. The construction type is noted as V-A on Sheet A010 and V-B on Sheet CS03. We have <br /> reviewed the building as V-B construction (assumed). <br /> 2. Electric vehicle charging locations and infrastructure requirements should be shown on <br /> the plans. Section 427 <br /> 3. The special inspector qualifications, required inspections and reporting requirements of <br /> RCW 64.55 should be shown on the plans. <br /> 4. Smoke detectors should be noted to be interconnected within each unit. Section <br /> 907.2.11.5 <br /> 5. The smoke detector located in the hallway of unit types 5.1 & 5.2 should be shown to be <br /> minimum of 3'away from the bathroom doors. Section 907.2.11.4 <br /> 6. The insulation in floor/ceiling assembly 8D is not permitted to exceed 3" in thickness and <br /> must be attached directly to the underside of the sub-floor unless an additional layer of <br /> GWB is added per U.L. <br /> // <br /> 0 3200 Cedar Street © 425.257.88 tlee@everettwa.gov <br /> Everett, WA 98201 425.257.8857 fax 0 everettwa.gov <br />