Miii
<br /> GENERAL UNIT PLAN NOTES77.
<br /> `1,
<br /> 1. LEVELS 13:TYPE V-B.- 'G ALL LEVELS FULLY A
<br /> 2. EESH ETSA040-A0411FORFIRE-RESISTI ENKLERED PER IASSEMBLYTYPES 3. JOHNSON BRAUNDI��_
<br /> n TYPICAL WALL TYPES:
<br /> 15200 52nd Ave.South
<br /> LEVELS 1 TO 3-TYPE V-B CONSTRUCTION Suite 300
<br /> Seattle,WA 98188
<br /> Phone 206.766.8300
<br /> Ai 36'-0'• EXTERIOR WALL PER ELEVATION
<br /> f /
<br /> / 7D UNIT DEMISING WALLS w,w+.johnsenpraund,com
<br /> ARCHITECTURE
<br /> / / /
<br /> / 11•-21/2" /2'-3"/ 11•-01/2" / 7B INTERIOR WALL(NON-LOAD BEARING) INTERIOR DESIGN
<br /> Greg L.Nhwne,NIA
<br /> / / / / 7C CORRIDOR WALL Jeffrey A.Williams,PA
<br /> 1 OD 1 OD 3. REFER TO OWNER PROVIDED FINISH&FIXTURE SCHEDULES.
<br /> \ \ I I H 11 \ \
<br /> OF —iL/—�cI I N I I F 4. O DOOR TYPE-SEE DOOR SCHEDULE ON SHEET A100
<br /> NV `k. \ 11— —l1 1
<br /> o II/7� 5. O WINDOW TYPE-SEE UNIT WINDOW SCHEDULE ON SHEET A100
<br /> •
<br /> I i, NO WINDOW AT "� _
<br /> \ DEMISING WALL SEE _ u' 6. NO UNITS LOCATED ON AN ACCESSIBLE STORY IN THIS BUILDING.
<br /> Oj = BUILDING PLANS SEE SHEET A001 FOR LOCATION OF TYPE'A'UNITS ELSEWHERE ON THE SITE.
<br /> I \ 7. COORDINATE W/DESIGN/BUILD ELECTRICAL&MECHANICAL:
<br /> ;-
<br /> b... BEDROOM 2 BEDROOM 3 II BEDROOM 4 HARDWIRED SMOKE/CO DETECTOR W/BATTERY BACK-UP (�855s
<br /> Q -INTERCONNECTED WITHIN EACH UNIT PER IBC SECTION 907.2.11.5. 1 \ I REGISTERED
<br /> 1 / ARCHITECT
<br /> 7 --? O EXHAUST FAN Q DRYER VENT
<br /> 5'-31/2" II "'\
<br /> / / El WHOLE HOUSE FAN PER IMC REQUIREMENTS FFREY ARTHUR WILLIAM
<br /> 3'-41/2" 7'-8"
<br /> 4--
<br /> 4 L� / o 0
<br /> .--\- POWER VENT WILL BE REQUIRED FOR DRYER
<br /> EXHAUST LENGTHS THAT EXCEED MANUFACTURER'S
<br /> (NH SPECIFICATIONS.COORDINATE DESIGN/BUILD
<br /> 1 _g J\ MECHANICAL
<br /> / =s= 7
<br /> N ry _ ' O g n ALIGN. J m\ N 8. ---- INDICATES LOCATION OF EXHAUST DUCTINGAllth
<br /> I C =O FOR DUCTS WITHIN JOIST SPACE-SEE DETAIL
<br /> 5 VENT THROUGH ROOF @ 3RD FLOOR
<br /> a a _ m O O 9. \\\\\INDICATES LOCATION OF DROPPED SOFFIT
<br /> \ — DN L x @ 7,0"MIN.SEE DETAIL A030
<br /> 5 4 C 10. ALL EXHAUST VENT TERMINATIONS MUST BE 3 FEET CLEAR FROM ANY
<br /> A150 OPERABLE OPENING INTO THE BUILDING,AND 10 FEET CLEAR FROM ANY
<br /> BATH 5 LAUND 5 - _ BEDROOM 6 MECHANICAL AIR INTAKE.GANG TERMINATIONS TOGETHER UNDER ONE
<br /> O 910 22X30 ATTIC SHROUD,AS POSSIBLE. Q 3
<br /> e
<br /> 7. o - ACCESS PANEL 11. FOR TYPICAL PLUMBING INSULATION,SEE DETAIL A030 ''
<br /> D
<br /> 72. FOR TUBS AT FIRE-RATED WALL AND FLOOR ASSEMBLIES SEE®® a
<br /> ` J -* 13. ELECTRICAL PANEL is,
<br /> \ \ II II 11-14—11 \ .
<br /> OO _ 14. S&P=SHELF 8 POLE. U�
<br /> \c'\ tl `"\ \ 18. O WATER HEATER.SEE DETAIL allrc
<br /> 3'-91rz" O 5'-2" UPn
<br /> / / / /
<br /> / 5'-101rz s-s" / s-71rz / UNIT INTERIOR ELEVATION NOTES o m
<br /> / 1T-0" / T-6" / 11'-6" / m
<br /> 1. DIMENSIONS ARE TO FACE OF G.W.B(NET),UNLESS NOTED OTHERWISE. o 92
<br /> / / 2. FIELD VERIFY ALL FINISHED DIMENSION PRIOR TO ORDERING CABINETS&
<br /> COUNTERTOPS.
<br /> �
<br /> L 3. PROVIDE BLOCKING AT TOILET PAPER HOLDERS,TOWEL BARS,DOOR STRIKES, K
<br /> 1 UNIT 5.1 TYPICAL-FLOOR 3 DRAPERIES,REMOVABLE CABINET SUPPORTS&GRAB BARS.
<br /> 1/4"=1'-0" ISSUE DATE: 07/19/19
<br /> KITCHEN KEYNOTES BATH KEYNOTES
<br /> © SCONCE _ I O CONCEAL DUCT AT RANGE HOOD O
<br /> Ki b1 NOT USED
<br /> EXHAUST,SEE UNIT PLANS FOR
<br /> 1 _., �- b EXTENT OF DROPPED SOFFIT. b2 NOT USED
<br /> ,, ,} O CABINETS W/ADJUSTABLE SHELVES
<br /> Q 1 - / / PER FINISH SCHEDULE. b3 NOT USED
<br /> _ m o 0 11'_ -0" 4•-0 2'-6" K3 COUNTERTOP&BACKSPLASH PER O NOT USED
<br /> ` MIIMININIIMMIIMINI� � / / / / / OWNER SPECIFICATIONS.
<br /> ��. ...�
<br /> IC ro il / / / / 4' 3" / b5 NOT USED
<br /> M 67 K4 NOT USED O NOT USED
<br /> II 3/4" 30" 30"1 ` '
<br /> 3/4"
<br /> I.
<br /> VERIFY R.O. VERIFY R.Or. 4,18"4, \ \ II -----H II (1 O II _\ \ K5 NOT USED b7 OWNER SPECIFICATION.F CATION.
<br /> o '0 o Kg b8 WIRE SHELVING
<br /> / 9 1 CARRIAGE BATH 2-C CARRIAGE BATH 2-D �\ \ \ II---H II �\ NOT USED B
<br /> ATE
<br /> 1/4"=,'-O• 1/4•'=7•-0• _ E O 69 COUTERIC TOI&
<br /> e _ COUNTERTOP&
<br /> �} NO WINDOW AT BLIND CORNER CABINET SPECIFICATION.BACKSPLASHER OWNER
<br /> -� O_ DEMISING WALL.SEE Kg MICROWAVE 8 HOOD PER OWNER u
<br /> SCONCE J BUILDING PLANS 10 VANITY CABINETS OWNER `3
<br /> LIVING DINING SPECIFIATION SPECIFICATION. w
<br /> .. a }\ }iF K9 NOT USED NOT USED,., ®1NOT USED N ALON VINYL VINYL 1 O
<br /> NOTUSED01 w
<br /> 1 2_ 41 €s
<br /> O VERIFY R.O. 111 ALIGN 1'-6" w m o$
<br /> O) ,}' �' VERIFYR. .78"� 24" 1" _ HOOD
<br /> El
<br /> �i�CARRIAGE BATH 1-C �fi�CARRIAGE BATH 1-D wNYL CPT 0 O - 'I O ———— © © -- w _ e E'y
<br /> o '
<br /> U 1/4=1-0•, 4••=1-7' 06 C © d E D New g=
<br /> N - I - 5 AD __-, - } I 4 Q a J NQ. �,,
<br /> F ® 0 7 O �/ 1� _���- ® RANGE 0 W g m3N ,3
<br /> A _ (� .BATH II Z/ KITCHEN Sc ' w 'S m P o
<br /> ._�.�. M.• OSET II > VINYL 01 m HE
<br /> 7•-17"MAX.MAx �.�_.... ��' F /NO SINK /y a o a�mn: <
<br /> L.
<br /> �� - --- -_ r 5 �, --- 3 LL
<br /> SOON E N� Q imirlim_;„,
<br /> >r [o o-II __ _ --- r---K-7
<br /> �, REF. HDW-
<br /> / BATH#1 I_1/
<br /> E.
<br /> C PROJECT#. 1705
<br /> N m m
<br /> V I I Of?EN i o \ sL OK II \ OL 1 \ DRAWN BY: ST
<br /> O /' ® , INE:m LJ ® _ _ _ CHECKED BY: ST
<br /> E. m r_� � _
<br /> N �� -- ADO / 3'-97rz"
<br /> m 3•-9"
<br /> ►�, „ I ��n m OW ill MIME 42 / / / FIVE BEDROOM UNIT
<br /> 1„ --_-- M / s•-111n^ 6'-0•' s•-6,n•• / 7•-s" / 1r-s•• / PLANS
<br /> II
<br /> U 4' 30 ,}' ,}',8'4' 2 3/4"{J, 30" I,18" , 30" 4,15"� 24'• 33•' 42'• 4, 36" 4, / /
<br /> .ff�r .f .{ ,f' ,f' ,f' / /
<br /> / ' 1 CARRIAGE 1/2 BATH 1-B �CARRIAGE KITCHEN 1-R / \CARRIAGE KITCHEN 1-A t 5 UNIT 5.1 TYPICAL-FLOOR 2
<br /> 1/4"=7•_U" V4"=l'-0' V4"=1�_0�. ,/4"=l'-0" ,y.•. Al 5 0
<br /> z s1�
<br /> BID/CONSTRUCTION
<br />
|