OTTO ROSENAU & ASSOCIATES, INC. <br /> Geotechnicat Engineering,Construction Inspection&Materials Testing <br /> PROPRIETARY ANCHOR ADHESIVE INSPECTION REPORT <br /> Job Number: 16-0804f Report Number: 339769 Permit Number: C1604-020 to 025 <br /> Project: Eclipse Townhomes—Bldg.2 Client: Polygon Northwest <br /> Address: 3301 31St Drive,Everett Address: 11624 SE 5th Street,Bellevue <br /> Inspector: Darren Reid Date: 4/13/2017 <br /> Description/Location: Inspected the epoxy grouted installation of 1",7/8",and 5/8"diameter all thread anchor bolts into existing <br /> thickened slab footing for HDU11,HDU8,and HDU5 holdowns along stairwell/party walls per CT-07 at building <br /> #2. The inspected work was found to be done as per approved project documents. <br /> Intended Use: Anchor bolts for holdowns Building Code&Year: 2015 IBC <br /> ❑;,Reinforcing Steel C3 All Thread <br /> Bar/Dowel Size&Quantity: Anchor Size&Quantity: 1"(4),7/8"(4),5/8"(4) <br /> Rebar Manufacturer: Type of Steel(ASTM): ❑A-36 ❑A-325 ❑A-449 <br /> Rebar Grade: ❑40 ❑60 0 Other: ❑Other: <br /> Type of Bar: 0 A-615 0 A-706 0 A-775 ❑Other: <br /> Special Ductile Quality(SDQ): ❑Yes ❑No <br /> Anchor Length: 16"-18" Hole Depth: 10",9",8" Required Embedment: 10",9",8" <br /> Hole Diameter: 1 1/8",1",a/," Concrete Thickness: Concrete Strength: <br /> Hole Orientation: ®Vertical Down ❑Vertical Up ❑Horizontal <br /> Base Material: ®Normal Weight Concrete 0 Light Weight Concrete ❑CMU ❑Brick ❑Composite Deck <br /> Hole Cleaning: ® Compressed Air ❑Hand Pump 0 Other: Compressed Air PSI: 80-100 <br /> Brushed: ®Yes 0 No Hole Condition: ®Dry to Damp ❑Water Saturated 0 Submerged <br /> Drill Bit(ANSI B212.15): ®Yes ❑No Approved Diamond Cored Hole: 0 Yes El No <br /> Adhesive Type: Simpson AT XP Expiration Date: 1/4/2018,12/4/2018 ICC ESR#: 263 <br /> Weather: Overcast with rain Ambient Temperature: 52°F Substrate Temperature: 50°F <br /> Comments <br /> Reference Standard(s)Used: Conforms X Does Not Conform <br /> Copies to: <br /> Client X Engineer X Others <br /> Owner. X Contractor Technical Responsibility: <br /> Architect X Building Dept. r H4t n,Project Manager <br /> This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau&Associates,Inc. Reproduction of this report, <br /> except in full,without written permission from our firm is strictly prohibited. <br /> Page 1 of 1 <br /> 6747 M.L.IGng Way S.,Seattle,Washington 98118—Phone(206)725-4600 or 1-888-OTTO-4-US-Fax(206)723-2221 <br /> Form No.:ADM/N-86-02(Rev.05/13) <br /> • <br /> r <br />
The URL can be used to link to this page
Your browser does not support the video tag.