Laserfiche WebLink
1 <br /> NOIDESIGN FIELD REPORT <br /> Project Name: Everett River Front-Eclipse(3) Report: 011 <br /> GeoDesign #: Polygon-128-03 Date: 1/26/2017 <br /> Reports with Unresolved Nonconformance Issues: Permit: <br /> PW 1504-055 <br /> Nick Abdelnour(Polygon) Randy Allen(City of Everett) Weather.Cloudy,40's <br /> i Arrival/Departure: <br /> Ron Bowen(Polygon) 1230/1300_..._._�—. <br /> Distribution: Doug Ross(Polygon) <br /> ` Paul McKee(City of Everett) i Prepared By: Joe Dapcevich <br /> DensityTest SummarySignature: --'" <br /> m Site Plan(s) m 9 <br /> Attachments: - �—"' <br /> Installation Records ❑Other Reviewed By: <br /> PURPOSE of VISIT: GeoDesign representative,Joe Dapcevich,was on-site to observe the mat foundation subgrade for <br /> Building 2. <br /> SUMMARY OF OBSERVATIONS: <br /> Building 2-Mat Foundation Observations(Foundation Subgrade): <br /> Upon arrival,GeoDesign noted that the foundation excavation subcontractor had finished excavation for the Building 2 mat <br /> foundation area. The mat foundation area generally consisted of a light brown/gray silty SAND with gravel which could be <br /> probed less than 2 inches using a 1/2 inch diameter soil probe. <br /> Relative compaction of the mat foundation subgrade was tested using a Troxier Moisture-Density gauge. In-place density <br /> • <br /> tests indicated that the material had been compacted to greater than 95%of its maximum dry density as determined by a <br /> Modified Proctor analysis. <br /> A summary of our observations and density tests taken today can be found in the attached Figure 1 and Nuclear Density <br /> Gauge Data. <br /> • <br /> This report presents opinions formed as a result of our observation of activities relating to geotechnkal engineering or environmental services,We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project Irrespective of the presence of our representative.Our work does not Include supervision or direction of the contractor,the contractor's employees <br /> or agents.Our firm is not responsible for site safety,This field report Is a DRAFT representation of our field observations,testing,and preliminary recommendations.The report can only be considered <br /> final upon review of the GeoDesign project manager,as Indicated by initials in the-Reviewed By'section. <br /> 10700 Meridian Avenue North,Suite 402 I Seattle,WA 98133 I 206.838.9900 <br /> 2502 Jefferson Avenue I Tacoma,WA 98402 I 253.203.0095 <br />