3313 31ST DR 2021-05-27
>
Address Records
>
31ST DR
>
3313
>
3313 31ST DR 2021-05-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/27/2021 8:00:21 AM
Creation date
5/17/2021 3:47:40 PM
Metadata
Fields
Template:
Address Document
Street Name
31ST DR
Street Number
3313
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CEO � FIELD REPORT1 of 3 ti <br /> Project Name: I Everett River Front-Eclipse Report: 085 • <br /> GeoDesign#: i Polygon-128-02 Date: 11/28/2016 <br /> Reports with Unresolved Nonconformance Issues: Permit: <br /> PW 1504-055 <br /> Nick Abdelnour(Polygon) Randy Allen(City of Everett) Weather: Rain, 50's <br /> Ron Bowen(Polygon) Arrival/Departure. 0845/1615 <br /> Distribution: �_... _. <br /> Doug Ross(Polygon) <br /> Paul McKee(City of Everett) Prepared By: Ben Weinberg, E.I.T. <br /> ❑m Site Plan(s)Installation Records .__Su <br /> ary Si <br /> 0 DensityTest Summary <br /> gnature. ��%�--- �-�'�'� <br /> Attachments. <br /> ❑Other Reviewed By: n/ <br /> PURPOSE of VISIT: GeoDesign representative, Benjamin Weinberg, was on-site full time at the request of Doug Ross with <br /> Polygon to observe the installation of ground improvement trenches for Building 3. <br /> SUMMARY OF OBSERVATIONS: <br /> Building 3 -South Ground Improvement Trench(Trench A): <br /> Beginning at approximately 9:15 AM, GeoDesign noted that BDZ continued excavation of Trench A from approximately 80 <br /> feet west of the east end using a CAT 336E excavator. GeoDesign noted that the trench area was at least 8 feet wide and <br /> was dug to 15.75 to 15 feet below ground surface, for two sections at approximately 25 and 20 feet in length. <br /> Material encountered within the trench consisted of gray to brown silty SAND with gravel from 0 to approximately 12.5 feet <br /> below ground surface. Material encountered below the silty SAND consisted generally of brown silty SAND with gravel <br /> (50%) mixed with debris(Red bricks: 40%, Concrete: 10%). Below the soil/debris layer, GeoDesign noted large <br /> dimensional lumber laying flat across the trench area. Below the dimensional lumber, GeoDesign noticed the contractor <br /> exposed a gray sandy SILT interpreted as native material. For the second section of trench excavated today, GeoDesign <br /> noted a large solid stump that the excavator couldn't remove and which was left in place. Once the native material was <br /> exposed at the base of the trench and the base of the excavation had been cleaned out, GeoDesign notified BDZ that the <br /> ground improvement trench could be backfilled. <br /> The material excavated from the trench which was not saturated and free of organics was mixed with an imported brown <br /> SAND with gravel and cement treated. The cement was added to the stockpile of excavated material using a punctured <br /> super-sack which was swung from the arm of an excavator. The stockpile was then thoroughly mixed and allowed to <br /> partially hydrate prior to backfilling the excavation. <br /> The first foot of backfill material consisted of 2-4 inch quarry spells tamped into a firm and unyielding mass using the bucket <br /> of an excavator. Beginning at approximately 14 feet below ground surface,the trench was backfilled using cement treated <br /> soil which was placed in 12 to 18 inch loose lifts and compacted using an excavator-mounted hoepack. <br /> The cement treated backfill material observed today will be checked to verify it has cured into a firm and unyielding mass <br /> tomorrow.A summary of our observations can be found in the attached Figure 1 and Photo Log. Penetration depths into <br /> cement treated backfill material placed last week was less than 1 inch. <br /> The client and contractor were notified of our observations prior to our departure from the site today. <br /> This report presents opinions formed as a result of our observation of activities relating to geotecnnicai engineering or environmental services.We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project irrespective of the presence of our representative.Our work does not include supervision or direction of the contractor,the contractor's employees <br /> or agents. Our firm is not responsible far site safety.This field report is a DRAFT representation of our field observations,testing,and preliminary recommendations.The report can only be considered <br /> foal upon review of the GeoDesign project manager,as indicated by initials in the"Reviewed By"section <br /> 10700 Meridian Avenue North,Suite 402 i Seattle,WA 98133 I 206,838.9900 <br /> 2502 Jefferson Avenue I Tacoma,WA 98402 I 253.203.0095 <br />
The URL can be used to link to this page
Your browser does not support the video tag.