My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3400 RIVERFRONT BLVD WHOLE SITE FILE 2021-05-18
>
Address Records
>
RIVERFRONT BLVD
>
3400
>
WHOLE SITE FILE
>
3400 RIVERFRONT BLVD WHOLE SITE FILE 2021-05-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/18/2021 7:47:13 AM
Creation date
5/18/2021 7:46:53 AM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
3400
Tenant Name
WHOLE SITE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Unit F Townhome Polygon Northwest Company <br /> Eclipse Jamie Aubrey <br /> Everett,Wa (425)586-7700 <br /> Heating System Type: O Forced Air Furnace 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Design Temperature Difference(AT) 47 <br /> Everett JC <br /> l AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Conditioned Floor Area(sq ft) 1,381 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.5 11,739 <br /> Glazing and Doors U-Factor X Area = UA <br /> 0.30 149 44.58 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions 0.026 674 17.52 <br /> R49 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor Area UA <br /> Instructions ..__ <br /> No Vaulted Ceilings in this project. • <br /> --- <br /> Above Grade Walls(see Figure1) U-Factor Area UA <br /> Instructions _..__._._.____....-_ - <br /> - R-zt . 0.056 662 37.07 <br /> Floors U-Factor Area UA <br /> Instructions ,.... <br /> R-30 • ¢ 0.029 564 16.36 <br /> Below Grade Walls(see Figural) U-Factor Area UA <br /> Instructions_- project. <br /> No Below Glade Walls in this --- --- <br /> Slab Below Grade(see Figural) F-Factor Len <br /> UA <br /> Instructions _. ........:........ _...... __.., . <br /> tat'No Slab Below Grade in this project. --- <br /> Slab on Grade(see Figure 1) F-Factor Len.th UA <br /> RtO Perimeter 0.540 37 19.98 <br /> Location of Ducts <br /> Instructions • <br /> i Duct Leakage Coefficient <br /> ,.Conditioned Space 4r.I 1 1.00 <br /> Sum of UA 135.51 <br /> Envelope Heat Load 6,369 Btu/Hour <br /> Figure 1. Sum ofuAXAT <br /> Air Leakage Heat Load 5,958 Btu/Hour <br /> VolumeX 0.6X AT X.018 <br /> Above Grade Building Design Heat Load 12,328 Btu/Hour <br /> Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 12,328 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 17,259 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> s <br /> (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.