My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3400 RIVERFRONT BLVD WHOLE SITE FILE 2021-05-18
>
Address Records
>
RIVERFRONT BLVD
>
3400
>
WHOLE SITE FILE
>
3400 RIVERFRONT BLVD WHOLE SITE FILE 2021-05-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/18/2021 7:47:13 AM
Creation date
5/18/2021 7:46:53 AM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
3400
Tenant Name
WHOLE SITE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table R402.1.1 Footnotes <br /> For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. <br /> a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is <br /> less than the label or design thickness of the insulation,the compressed R-value of the insulation from <br /> Appendix Table A101.4 shall not be less than the R-value specified in the table. <br /> n The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. <br /> Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 <br /> through 3 where the SHGC for such skylights does not exceed 0.30. <br /> "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous <br /> insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the <br /> basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 <br /> cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or <br /> exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R- <br /> 13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and <br /> basement wall. <br /> e R-10 continuous insulation is required under heated slab on grade floors.See R402.2.9.1. <br /> e There are no SHGC requirements in the Marine Zone. <br /> Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table <br /> R301.1. <br /> g Reserved. <br /> " First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13 <br /> cavity insulation plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent <br /> or less of the exterior, continuous insulation R-value shall be permitted to be reduced by no more than R-3 in <br /> the locations where structural sheathing is used to maintain a consistent total sheathing thickness. <br /> The second R-value applies when more than half the insulation is on the interior of the mass wall. <br /> For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38. <br /> k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a <br /> minimum of R-10 insulation. <br /> Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation <br /> requirement. <br /> Table R402.1.3 Footnote <br /> a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as <br /> specified in Section R402.1.3. <br />
The URL can be used to link to this page
Your browser does not support the video tag.