Laserfiche WebLink
• <br /> • <br /> • <br /> • <br /> groundwater beneath the site likely corresponds to the elevation of the river. However, it is • <br /> possible that perched groundwater is present at shallower depths. <br /> • <br /> 5.0 CONCLUSIONS • <br /> • <br /> 5.1 SUMMARY • <br /> Based on our review of the available information and the results of our explorations, it is our • <br /> opinion that the site can be developed as proposed. The following items will have an impact on <br /> design and construction of the proposed project. Our specific recommendations for site • <br /> development and design are provided in the following sections of this report. <br /> • <br /> • A 5-foot or 10-foot-high surcharge fill should be installed across part of the site to accelerate <br /> primary and secondary settlement. We recommend monitoring of settlement plates to • <br /> determine when the surcharge fill has adequately consolidated the site. • <br /> • The proposed townhomes can be supported on mat foundations. The mat foundations will <br /> mitigate settlement that might result from the decomposition of the wood debris observed in • <br /> the undocumented fill layer. The upper 24 inches of foundation subgrade should be <br /> evaluated during construction to verify that it has been adequately compacted. • <br /> • We recommend that the upper 24 inches of roadway subgrade be properly compacted. • <br /> Alternatively, we recommend cement amending the upper 16 inches of subgrade. • <br /> • Our analysis indicates that liquefaction-induced seismic settlement will likely occur during a <br /> design-level earthquake. The structural engineer should determine if the magnitude of • <br /> seismic settlement is within acceptable limits. • <br /> • Our analysis indicates that lateral spreading will likely occur during a design-level earthquake <br /> that will impact the row of townhomes along the eastern edge of the site that are closest to <br /> • <br /> the riverbank. We recommend that the townhomes be supported on mat foundations,which <br /> will mitigate the risk of damage from lateral spreading. • <br /> • <br /> 5.2 LONG-TERM SETTLEMENT CAUSED BY FILLING • <br /> 5.2.1 Existing Utilities and Grading Plans <br /> • <br /> The site includes several existing utilities, some of which will remain in service and some will be <br /> replaced or abandoned as part of the project. The locations of the utilities that will remain in • <br /> place are shown on Figure 2. We understand that the following utilities are present at the site: • <br /> • A 48-inch-diameter pressurized sanitary sewer line constructed in 1985 of prestressed <br /> concrete cylinder pipe. The pipe invert elevation is approximately-2.5 feet. This sanitary • <br /> sewer line will be covered by up to 10 feet of new fill (typically around 8 feet of fill) and will • <br /> remain in service. This pipeline is currently located beneath the drainage swale. • <br /> • A 72-inch-diameter pressurized sanitary line constructed in 1995 of reinforced concrete pipe • <br /> that is supported on piles. The pipe invert elevation is approximately 0.5 foot. This sanitary <br /> sewer line will be covered by up to 5 feet of new fill (typically around 4 to 5 feet of fill) and • <br /> will remain in service. This pipeline is currently located beneath the eastern side of the • <br /> drainage swale. • <br /> • <br /> • <br /> • <br /> • <br /> G EODESIGN= 6 Polygon-128-01:091615 • <br /> • <br />