My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2514 RAINIER AVE 2022-03-01
>
Address Records
>
RAINIER AVE
>
2514
>
2514 RAINIER AVE 2022-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2022 10:45:56 AM
Creation date
6/9/2021 10:17:56 AM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER AVE
Street Number
2514
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
541
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Jun 2016 <br />Project Title: North Middle School Modernization <br />Date 03/22/2018 <br />Fenestration Area as % gross above -grade wall area 22.2% Max. Target: 4 0 . 0 % <br />For Building Department Use <br />Skylight Area as % gross roof area 0.2% Max. Target: 3. 0% <br />Building Component <br />Proposed UA <br />Target UA <br />Ins. R Plan/Detail # F-factor Source & Table # 8 <br />F-factor x Perimeter = UA(U x A) <br />F-factor x Perimeter = UA (U x A) <br />cD <br />R= 10 <br />1/A5.01 <br />0.066 <br />1239 <br />81.8 <br />0.540 1239 669.1 <br />r <br />R= <br />Slab -On -Grade F-0.54 <br />Co <br />m <br />c <br />c <br />� <br />R _ <br />o <br />-o <br />R= <br />0.550 <br />� <br />co <br />0 <br />m <br />R= <br />Heated Slab -On -Grade F-0.55 <br />F <br />am <br />= <br />R= <br />Schedule ID <br />U-factor Source910 <br />U-factor x Area (A) = UA (U x A <br />U-factor x Area (A) = UA (U x A) <br />Typ door, no glazing <br />WSEC Table Al07.1 (1) <br />0.370 <br />558 <br />206.5 <br />0.37 558 206.5 <br />Opaque Swing Doors U-0.37 <br />a <br />c <br />.3 <br />E <br />`0 <br />co <br />0 <br />0.34 <br />r <br />Opaque rollup & sliding U-0.34 <br />O <br />0.30 <br />Non -Metal Frame U-0.30 <br />c <br />0 <br />z <br />SF (P-EFC-22193) <br />0.38 <br />850 <br />323.0 <br />0.38 1 11080 4210.4 <br />Metal Frame, Fixed U-0.38 <br />c <br />CW (P-EFC-28065) <br />0.38 <br />10230 <br />3887.4 <br />o <br />r. <br />_ <br />ca <br />m <br />� <br />a) <br />0.40 <br />LL <br />Co <br />0 <br />Metal Frame, Operable U-0.40 <br />U_ <br />�p <br />y <br />a) <br />Storefront Door <br />NFRC Fenestration Calculation Report <br />0.60 <br />128 <br />76.8 <br />0.60 128 76.8 <br />Metal Entrance Door U-0.60 <br />2 <br />c <br />N <br />w <br />Acrylic <br />WSEC Table C402.4 <br />0.50 <br />96 <br />48.0 <br />0.50 96 48.0 <br />t <br />a <br />All types U-0.50 <br />� <br />Q <br />Page 2 Subtotal <br />Area' I UA Area' I UA <br />105227 <br />7586 <br />13101 <br />5211 <br />92126 <br />3585 <br />105227 <br />8796 <br />Page 1 Subtotal <br />TO COMPLY- The Proposed Total UA shall not <br />exceed the Target Total UA. Project Total <br />Note 1 - If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1, then Target Area Adjustment of all applicable envelope <br />elements will be calculated automatically by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. <br />Note 2 - Opaque assembly U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br />Note 3 - Proposed CMU mass wall in non -Group R that meet Table C402.1.4 Footnote D requirements can enter the target U-value of 0.014 <br />Note 4 - For semi -heated spaces utilizing the wall insulation exception, enter Target Wall U-factors under Proposed Wall U-factors so exterior <br />walls are neutral to the calculation. <br />Note 5 - Mass transfer slab edges must be covered with an assembly having an overal U-factor of 0.2. <br />Note 6 - Demising walls, doors, and vertical fenestration separating spaces with different degrees of space conditioning (unconditioned, semi -heated, <br />fully conditioned) shall be included only on the ENV-UA form for the space with the greatest degree of space conditioning. <br />Note 7 - List Group R above grade mass walls here. List all other mass walls, Commercial and Group R, in the Opaque Walls - Above Grade section. <br />Note 8 Slab -on -grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br />Note 9 Opaque door U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. A door is defined as <br />opaque if less than 50% of the door area has glazing. <br />Note 10 - Fenestration assembly U-Factors shall be the manufacturer's NFRC product rating, which includes the glazing and frame, or shall be <br />the default value per Section C303.1.3. <br />
The URL can be used to link to this page
Your browser does not support the video tag.