Laserfiche WebLink
F 7 <br /> SW>/4,SW>/4,SEC36,T29,R04 <br /> CITY OF EVERETT, WASHINGTON <br /> NOTES: <br /> 1. Reference Riley Group Geotechnical Report <br /> August 21, 2019 <br /> TABLE 1705.6 REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS Ms. Isha Daramy <br /> PAL 1501 150th Place Southwest <br /> 1 9 0' Lynnwood, Washington 98087 <br /> CONTINUOUS SPECIAL PERIODIC SPECIAL RE: Geotechnical Recommendations <br /> TYPE INSPECTION INSPECTION 4841 Glenwood Avenue <br /> 14 5' Everett, Washington <br /> 1.Verify materials below shallow RGI Project No. 2016-072 <br /> REVERSE SLOPE foundations are adequate to - X <br /> 6" CURB & GUTTER achieve the design bearing capacity- 2. "Accordingly, for excavations more than 4 feet <br /> but less than 20 feet in depth, the temporary side <br /> SAWCUT NEAT slopes should be laid back with a minimum slope <br /> RELOCATE ECO-BLOCK 2.Verify excavations are extended to <br /> LINE DRIVEWAY inclination of 1.5H:1V(Horizontal:Vertical) in the <br /> TO DBL WALL BASE�r -, proper depth and have - X <br /> rn existing fill and 3/4H:1V in the native soils. In all <br /> w ' ' reached proper material. <br /> • I cases, however, appropriate inclinations will depend <br /> n _ on.the actual soil and groundwater conditions <br /> 0 3 3.Perform classification and testing of <br /> z I I- T - T - X encountered during earthwork. Ultimately, the site <br /> compacted fill materials. <br /> J 1 I III—I Ir.. f' I contractor must be responsible for maintaining safe <br /> FULL FLAT TOP BLOCK ,=III—III—I I I ICI I I I I—I I , L J 4.Verify use of proper materials,densities excavation slopes that comply with applicable OSHA <br /> AT TOP COURSE ,,I=11I-III—III I—III I—I11II1I , and lift thicknesses X or WISHA guidelines." <br /> - <br /> TOW EL 207.9' I '1 1-1 I I—III I 1--ITI- I I I 6" COMP. CRUSHED during placement and compaction of <br /> I' L µ-ry- ROCK BASE COURSE compacted fill. 3. "RGI anticipates that the native soils will be <br /> 1 I-i-�= t`T I 'I I—I I I _ III-III- p reusable as structural fill provided they can be <br /> 1— - MAINTAIN STABLE 5.Prior to placement of compacted fill, moisture conditioned and compacted. The native <br /> —I I I I—III—III—III—III—III ESCAVATION BACKSLOPE inspect sub grade and verifythat site - X soils are moisture sensitive and will require moisture <br /> ■ � o i—I I III—III—III—III—III/ ha been prepared proprl. conditioning (drying out) prior to use as structural <br /> 6.0' TO GRADE ; D :III II—III—III—III—III% fill. In order to maximize utilization of site soils <br /> 1 CLASSIFIED BACKFILL as structural fill, RGI recommends that the <br /> 1 I I� III-III—III-III- earthworkportion of this project be completed <br /> COMP. TO 92% D-1557 P j P <br /> TURN 2ND BLOCK t' 73i-'L :I—III-I I — during extended periods of warm and dry weather if <br /> ESTABLISH UNIFORM ( �o o , I �- _—i,� <br /> GRADE w/FLOWER BED INTO BACKFILL • i-r +d I I I—III—III— possible." <br /> �� 'LP—III—II_l/ Special Inspections for Block Wall Construction <br /> FREE DRAINING BACKFILL WRAPPED <br /> _ " , = 4. "Thepermanent fill slope above the wall should <br /> '1:4:- IN GEOTEXTILE FABRIC BEHIND WALL <br /> DOUBLE 1ST BLOCKS • <br /> .• "i}}_�.,,I CONTINUOUS SPECIAL be graded with a finished inclination no greater <br /> ON LEVELING COURSE ►.!-''� 7 ••�.: r r�1 I-III—i� TYPE PERIODIC SPECIAL INSPECTION than 3H:1V. Upon completion of construction, the <br /> 1,�, III1 , INSPECTION slope face should be trackwalked, compacted <br /> •�_ °'-I _I 1.Verify block placement and vegetated, or provided with other physical <br /> 6" CRBC COMPACTED .o� , •. ,.4r �,_I I I_�/' means to guard against erosion. All fill placed for <br /> TO 95% D-1557 ` _I ICI 1, including batter,interlock and - X slope construction should meet the structural fill <br /> 19, r.i, 7 <br /> 1 1 stacking requirements as described above." <br /> 4" <br /> TIE TO EXISTING CB<-.• S _ T1GHTLINE PI PEROE IN SOCK <br /> TO EXTG. CB 2.Verify drainage installation X <br /> including pipe and rock DEVELOPMENT DATA: <br /> 6" PVC DRAIN SET IN EXISTING ZONING 111-SNGLE FAMILY <br /> CONCRETE w/ (4) 4 3.Monitor fill placement per X PROPOSED; REBUILD ECO-SLOG(RETAIN'G WALL <br /> # above schedule MPACTED SITEIAL VOLUME: <br /> 3,00000 SF(007 Ac)CY M� <br /> ENGINEER CONTACT: MARMADUKE CONSULTING <br /> POE 1404 <br /> MUKILTEO,WA 98275 <br /> 360-447-8753 <br /> ANTHAEOGMAILCOII <br /> GEOTECHNICAL CONTACT: THE RILEYR°cuP <br /> L,WA 9B011 <br /> WAY NE <br /> BOTH425-425-41s <br /> -0551 <br /> KNELLERORILEY-GROUP.W M <br /> PROPERTY OWNERS: es BANK TRUST NA TTEE <br /> /o SLAYTON HOMES <br /> EVERETT,WA 98208 <br /> 425-212-2007 <br /> OM <br /> WALL SECTION aH��AYDNHa <br /> R<IrMAR'1�o LEGAL DESCRIPTION: <br /> S SEC 36 PIP 29 RGE 04RT-16A-)BEG AT NE CO OF SWI/4 <br /> SWI/N TS 160E7 TH S t0oF TPB B CON S RD W P TH N <br /> �, 160FT THE 660FT TO TPB LESS 30FT RD ON E LESS FOLG Pi <br /> BEG NE COR SW1/4 SWI/4 TH 5 200FT ALG E LN TO TPB TH S <br /> 60E7 TH W PLT N LN 160F7 TH N PLT E IN 60FT TH E PLL TO N <br /> ?o�F�'oTSTE "� LN 160FT TO TPB ALSO LESS BEG NE COR SWI/4 SWI/4 TH S <br /> '.670,vnt 6v' 100E7 TO TPB TH S 10017 TH W PLL TO NLN SO SUB 160E7 TH N <br /> 100Fr TH E 160FT TO TPB <br /> SITUATE IN THE COUNTY OF SNOHOMISH,STATE OF WASHINGTON <br /> CITY OF EVERETT TAX ACCOUNT NO: SITUS ADDRESS: <br /> PERMIT SERVICES 29043600302000 4841 GLENWOOD AVE <br /> APPROVAL FOR CONSTRUCTION EVERETT, WA 98203 <br /> BY: <br /> R/W PERMIT NUMBER: <br /> UTILITY CONFLICT NOTE: MARMADUKE RETAINING WALL RECONSTRUCTION PLAN FOR: <br /> THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, D A l�A 11 8 V O O I 1 D A D <br /> DIMENSION AND DEPTH OF ALL EXISDNG UTILITIES,WHETHER SHOWN ON ISHA !"1r�/1�VL 1 O lJ A <br /> THESE PLANS OR NOT,BY POTHOLING THE UTILITIES AND SURVEYING CONSULTING <br /> CALL TWO (2) SW1/4,SWf/4,SEC36,T29,RO4 <br /> THE HORIZONTAL AND VERTICAL LOCATIONS PRIOR TO CONSniucTTON. <br /> BUSINESS DAYS THIS SHALL INCLUDE CALLING UTILITY LOCATE AT 1-800-424-5555 AND CITY OF EVERETT, WASHINGTON <br /> P F N: BEFORE YOU DIG THEN POTHO NG ALL INDICATED UTILI E5 AT LOCATIONS OF TRENCH (360) 447-8753 DRANK BY: DATE REVISION DATE PM/Edi SCALE <br /> CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. D1 2fiAUG R.MARMADUKE NOTED <br /> LOCATIONS OF PRIVATE UTIDRES ARE NOT SHOWN ON THESE PLANS.IF ANTHAE360 LLC, a WA 8832 RAM 19AUDA <br /> 1-800-424-5555 UTILITIES ME DISCOVERED CONTACT THE LOCAL UTILITY*ITN <br /> POB 1404, MUKILTEO, WA 98275 ORANING FILE -- JOB REFERENCE SHEET NO �+ <br /> FOR UTILITY TYPE UNCOVERED,TO RESOLVE CONFLICTS MTN TH NE NEW MORK. 19018DARAMY -- 4841 GLENWOOD 2 OF 3 I J <br /> L J <br />