My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4841 GLENWOOD AVE 2021-06-09
>
Address Records
>
GLENWOOD AVE
>
4841
>
4841 GLENWOOD AVE 2021-06-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2021 3:20:29 PM
Creation date
6/9/2021 3:18:45 PM
Metadata
Fields
Template:
Address Document
Street Name
GLENWOOD AVE
Street Number
4841
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f-1 <br /> SW1/4,SW1/4,SEC36,T29,R04 <br /> CITY OF EVERETT, WASHINGTON <br /> C <br /> NOTES: <br /> P/L 1. Reference Riley Group Geotechnical Report <br /> 1 9.0' August 21, 2019 <br /> Ms. Isha Daromy <br /> 1501 150th Place Southwest <br /> _ <br /> 14.5' Lynnwood, Washington 98087 <br /> RE: Geotechnical Recommendations <br /> 4841 Glenwood Avenue <br /> ton <br /> REVERSE SLOPE RGIrett PojectsNohin92016-072 <br /> 6" CURB & GUTTER <br /> 2. "Accordingly, for excavations more than 4 feet <br /> SAWCUT NEAT but less than 20 feet in depth, the temporary side <br /> RELOCATE ECO—BLOCK slopes should be laid back with a minimum slope <br /> — LINE DRIVEWAY inclination of 1.5H:1V Horizontal:Vertical in the <br /> rn TO DBL WALL BASE�r —1 ( ) <br /> LU I I i existing fill and 3/4H:1V in the native soils. In all <br /> cases, however, appropriate inclinations will depend <br /> II on the actual soil and groundwater conditions <br /> 0 _ III- —I-——T"% encountered during earthwork. Ultimately, the site <br /> Z - r contractor must be responsible for maintaining safe <br /> _ ' � �' excavation slopes that comply with applicable OSHA <br /> wFULL FLAT TOP BLOCK v 1 , . 1=I I =I I II I I IIIII I III—I I II I L�!J or WISHA guidelines." <br /> AT TOP COURSE I -H 3. "RGI anticipates that the native soils will be <br /> — TOW EL 207.9' n I I I—�I I—III—III I—I I I I I I—I I I—I I—I reusable as structural fill provided they can be <br /> _ I —I I—III I I J I }I-111'�I -1 �I I 6" COMP. CRUSHED moisture conditioned and compacted. The native <br /> I I,--4--E_ I 111—I� 1 I III—III-� ROCK BASE COURSE soilsn ion moisturedryi sensitive and will require moisture <br /> .°^p� ,� � conditioning (drying out) prior to use as structural <br /> 1 MAINTAIN STABLE fill. In order to maximize utilization of site soils <br /> I—I I IT'I I I-III—III—III—III—III-L— as structural fill, RGI recommends that the <br /> n '�. "` ' ' ! 1- r— ESCAVATION BACKSLOPE earthwork portion of this project be completed <br /> • i-rr�... • i—I I11-III—III—III—III—III-i/ during extended periods of warm and dry weather if <br /> ' ° I I I I I—III—III—III-III- possible." <br /> 6.0' TO GRADE I 4°'."5 I i— ;/, CLASSIFIED BACKFILL <br /> 1 0 .' • 84v:°�4-I ICI I I—III—III—III— 4. "The permanent fill slope above the wall should <br /> • °.. III COMP. TO 92% D-1557 be graded with o finished inclination no greater <br /> ESTABLISH UNIFORM TURN 2ND BLOCK ..... r °D''',4411III—I I / than 3H:1V. Upon completion of construction, the <br /> .'-'1-'‘... <br /> /'TT1 ;o I I 1 —I slope face should be trackwalked, compacted <br /> INTO BACKFILL •"'" '7 7_ _ and vegetated, or provided with other physical <br /> GRADE w/ FLOWER BED ;:l D �.$�1I I I-III-III— P p <br /> • e '''Lair ?—III—III I/ means to guard against erosion. All fill placed for <br /> d �I" _— , FREE DRAINING BACKFILL WRAPPED slope construction should meet the structural fill <br /> DOUBLE 1ST BLOCKS ''a .• •4:1 �_ _/ IN GEOTEXTILE FABRIC BEHIND WALL requirements as described above." <br /> ON LEVELING COURSE I' -�TT, - TT. k b '(—III—I'' <br /> `" j—III—I/ DEVELOPMENT DATA: <br /> • '.' • qD .'^p -I I� 111-SNGIE FAMILY <br /> 6" CRBC COMPACTED '.° ICI I I—I I PROPOSED:VOLUME: REBUILD ECOL/TOOT RETAM'WALL <br /> TO 95% D-1557 ...' .° ' - _I IT- I/ IMPACTED SITE AREA• 3.000 SF(a07 AC) <br /> �TT1. ,-Tr, 1—I ' ENGINEER CONTACT: ., CONSULTING <br /> I <br /> 4" MU3ILTE 4 PERF—PIPE IN SOCK WA 96276 <br /> �447-8753 <br /> TIE TO EXISTING CB N' 6 .. TIGHTLINE TO EXTG. CB ANTNAEOGMML <br /> COM <br /> GEOTECHNICAL CONTACT: 1752 RILEYTM Y NE <br /> BOTHELL WA 98011 <br /> 6" PVC DRAIN SET IN NKIIELL0l�r'-GROUP.COM <br /> CONCRETE w/ (4) #4 PROPERTY OWNERS: US BANK TRUST NA TIEE <br /> 0/4 SLAYON HOMES <br /> DERETT.WA 98208 <br /> 425-212-2007 <br /> CHADCQLAYIONHOMESCOM <br /> ''o'S;-'p LEGAL DESCRIPTION.I : <br /> 1 �NSif/L L.(- <br /> Y`;<f a cr4, SEC 36,DIP 29 RGE 04RT-16A-)BEG AT NE CN OF SWI/4 <br /> SWI/4 1H S 100E7 TPB TH CONY S 160FT TH W 660FT TH N <br /> ' 160F7 TH E 660FT TO TPB LESS 30FT RD ON E LESS FOLG PT <br /> BEG NE COR SW1/4 SWI/4 TH S 200FF ALG E IN TO 7PB TH S <br /> ' 16iJ� 'rA 60FT TH W PIT N IN 160E7 TH N PLT E IN 60FT TH E PLL TO N <br /> �GfS o, IOOF'F To TP8TO�7H S IOOOFT TH W PLL O FIN S LESS BEG NE COR /D45UB 16OFF TH N <br /> WALL SECTION SITUALN TE <br /> E E THEFT TO Y O <br /> SITUATE IN THE COUNTY OF SNOHOMISH,STATE OF WASHINGTON <br /> CITY OF EVERETT TAX ACCOUNT NO: SITUS ADDRESS: <br /> N TS PERMIT SERVICES 29043600302000 4841 GLENW00D AVE <br /> APPROVAL FOR CONSTRUCTION EVERETT,WA 98203 <br /> BY: <br /> _ R/W PERMIT NUMBER: <br /> UTILITY CONFLICT NOTE: RETAINING WALL RECONSTRUCTION PLAN FOR: <br /> THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFTNG THE LOCATION, MARMAD U KE ISHA DARAMY-BOUDAD <br /> DIMENSION AND DEPTH OF ALL DOSING UTIUTIES,WHETHER SHOWN ON <br /> CALL TWO (2) THESE THE PLANS OR NOT,BY POTHOLING THE UTIUTIES AND SURVEYING CONSULTING SW1/4,SW1/4,SEC36,T29,R04 <br /> HORIZONTAL MD VERTICAL LOCATIONS PRIOR TO CONSTRUCTION. <br /> (360) 447-8753CITY OF EVERETT, WASHINGTON y <br /> BUSINESS DAYS THIS SHALL INCLINE CALLING UTRJTY LOCATE Al 1TIONS 24-5555 AND A <br /> THEN POTHOLING ALL INDICATED CRUDES AT LOCATIONS OF TRENCH DRAWN BY: DATE MASON DATE PY/Eelt SCALE 5,% <br /> P F N: BEFORE YOU DIG CROSSINGS TO PHYSICALLY LEROY WHNOT OR NOT CONFLICTS COST. RAM 19AUG19 01 28AU0 R.MARMADUHE NOTED <br /> LOCATIONS OF PRIVATE UTILITIES ARE NOT SHOWN ON THESE PLANE IF ANTHAE360 LLC, a WA 8832 <br /> 1-800-424-5555 DOUSES ARE DISCOVERED CONTACT 7HE LOCAL UTTUTY RIPRESENTAIINE POB 1404, MUKILTEO, WA 98275 DRAWING FILE -- JOB REFERENCE SHEET NO <br /> I FOR UTILITY TYPE UNCOVERED,TO RESOLVE CONNCTS WITH NEW WORK. ,90180ARAMY 4841 GLENWOOD 2 OF 3 <br /> L <br />
The URL can be used to link to this page
Your browser does not support the video tag.