Laserfiche WebLink
SYMBOLS: <br /> ABBREVIATIONS: GENERAL NOTES: <br /> ALUM ALUMINUM SIM SIMILAR DETAIL DESIGNATOR <br /> AFF ABOVE FINISHED FLOOR SJ SCORE JOINT 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 2015 INTERNATIONAL BUILDING CODE. A COPY OF THE APPROVED PLAN SHALL BE <br /> ARCH ARCHITECT,ARCHITECTURE SOG SLAB ON GRADE ON SITE WHENEVER CONSTRUCTION IS IN PROGRESS. <br /> @ AT SST STAINLESS STEEL r 1 <br /> AVE AVENUE STRUCT STRUCTURE OR STRUCTURAL I I 2. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN <br /> BATT BATTEN THK THICK,OR THICKNESS I I AND TO FURTHER DISCOVER AND AVOID HARM TO ANY OTHER BUILDING UTILITIES NOT SHOWN HEREIN WHICH MAY BE AFFECTED BY <br /> BLD BUILDING TOC TOP OF CURB Avihu THE IMPLEMENTATION OF THIS PLAN. <br /> B.O.S. BOTTOM OF STRUCTURE • TOR TOP OF RAIL AREA OF IMAGE <br /> BOT BOTTOM TRD TREAD j\\_ <br /> 3. THE CONTRACTOR SHALL TAKE APPROPRIATE STEPS REQUIRED TO PROTECT EXISTING UTILITIES,EQUIPMENT OR BUILT-IN FURNISHINGS <br /> CAB CABINET TYP TYPICAL REMAINING IN THE WORK AREA DURING CONSTRUCTION. <br /> CCTV CLOSED CIRCUIT TELEVISION UNO UNLESS NOTED OTHERWISE SHEET NUMBER WHERE <br /> CES CUSTOMER EMERGENCY STATION VERT VERTICAL THE DETAIL IS SHOWN 4. ALL DEMOLITION DEBRIS SHALL BE LEGALLY DISPOSED OF,OFF SITE. <br /> CIP CAST IN PLACE VIF VERIFY IN FIELD (DASH IF ON SAME SHEET ONLY) <br /> CJ CONSTRUCTION JOINT W/ WITH 5. DO NOT SCALE THE DRAWINGS. <br /> COL COLUMN W/O WITHOUT <br /> COMM COMMUNICATION(S) 9. OVERALL DIMENSIONS INDICATED ARE TO FINISH SURFACES OR STRUCTURAL GRID-LINES AND OTHER DIMENSIONS ARE TO FACE OF <br /> CONC CONCRETE CAST IN PLACE CONCRETE,OR FACE OF STRUCTURE UNLESS NOTED OTHERWISE. <br /> CONST CONSTRUCTION <br /> CONT CONTINUOUS SYMBOLS: 10. DRAWING SCALES SHOWN ARE BASED ON A SHEET SIZE OF 34 X 22 INCHES.IF THE PRINTED SHEET SIZE IS 17 X 11 INCHES,THEN THE <br /> D DEPTH DRAWINGS HAVE BEEN REDUCED TO HALF THE SCALE INDICATED. <br /> DET,DTL DETAIL <br /> DIA DIAMETER DRAWING DESIGNATOR 11. THE DRAWINGS AND SPECIFICATIONS TOGETHER COMPRISE THE CONSTRUCTION DOCUMENTS. ANY DISCREPANCIES BETWEEN THEM <br /> DIM DIMENSION OR BETWEEN TWO OR MORE DRAWINGS SHALL BE REFERRED TO THE RESIDENT ENGINEER BEFORE ANY WORK AFFECTED IS <br /> DN DOWN X DRAWING TITLE/NAME PERFORMED. <br /> DWG(S) DRAWING(S) <br /> EA EACH XXXXX SCALE: 12. SEE CIVIL DRAWINGS FOR LAYOUT AND DETAILS OF PAVEMENTS AND CURBS. <br /> EJ EXPANSION JOINT �� <br /> ELEV ELEVATION SHEET NUMBER WHERE DRAWING 13. SEE DRAINAGE DRAWINGS FOR UNDERGROUND PIPING INFORMATION. <br /> ELEC ELECTRICAL IS CALLED OUT GRAPHICS LEGEND: <br /> EQ EQUAL 14. SEE STRUCTURAL DRAWINGS FOR STRUCTURAL ELEMENTS AND ATTACHMENT INFORMATION. <br /> EXIST EXISTING • - <br /> EXT EXTERIOR DRAWING DESIGNATOR • ' • CIP CONCRETE(PLAN,SECTION,AND 15. SEE MECHANICAL DRAWINGS FOR MECHANICAL AND PLUMBING INFORMATION. <br /> FE FIRE EXTINGUISHER ELEVATION) <br /> FEC FIRE EXTINGUISHER CABINET 16. SEE ELECTRICAL DRAWINGS FOR TYPE OF INTERIOR LIGHTING LOCATION,SEE CIVIL DRAWINGS FOR EXTERIOR LIGHTING LOCATIONS <br /> FIXT FIXTURE jf// <br /> FT FOOT OR FEET PRECAST CONCRETE(PLAN,SECTION, 17. FOR COLORS AND FINISHES,SEE SPEC 09 06 00 COLORS AND FINISHES SCHEDULE.BRING ANY DISCREPANCIES BETWEEN <br /> F.O.C. FACE OF CONCRETE OR FACE OF CURB DRAWING TITLE/NAME AND ELEVATION) SPECIFICATION SECTIONS AND BETWEEN SPECS AND DRAWINGS TO THE ATTENTION OF THE OWNER. <br /> F.O.I.C. FURNISHED BY OWNER,INSTALLED BY CONTRACTOR SCALE: <br /> F.O.S. FACE OF STEEL 18. PROVIDE 8 FOOT MINIMUM CLEARANCE FROM GRADE TO UNDERSIDE OF CANOPY STRUCTURE. <br /> GA GAUGE MORTAR/GROUT FILL <br /> GALV GALVANIZED DRAWING SHOWN ON <br /> ot GL GLASS SAME SHEET ONLY <br /> e GWB GYPSUM WALL BOARD STEEL <br /> s HDWR HARDWARE SHEET LIST TABLE PROJECT INFORMATION <br /> u' HORZ HORIZONTAL SECTION DESIGNATOR 2015 INTERNATIONAL BUILDING CODE <br /> 8 HR HOUR Sheet Number Sheet Title occuPANcv:pf cc <br /> HM HOLLOW METAL ALUMINUM A0.1 LEGEND&ABBREVIATIONS BUILDING CONSTRUCTION:V az HSS HOLLOW STRUCTURAL SECTION(STEEL) <br /> ] <br /> alkA1.0 SITE PLAN OCC L040: ie? <br /> IBC HEIGHT A3.0 FULL SHELTER <br /> INTERNATIONAL BUILDING CODE XXXX)CX <br /> IN INCH `...._„../��SHEET NUMBER WHERE THE kkxXK { RIGID INSULATION (PLAN AND SECTION) A3.1 NARROW SHELTER <br /> � PROJECT INCLUDES: <br /> INFO INFORMATION SECTION IS SHOWN (2)FULL SHELTERS: <br /> A3.2 SHELTER SECTIONS <br /> INSUL INSULATION 432 SF <br /> JB JUNCTION BOX A3.3 SHELTER DETAILS <br /> JT JOINT CONTINUOUS BLOCKING A3.4 SHELTER DETAILS (4 TERS: <br /> LED LIGHT-EMITTING DIODE ELEVATION DESIGNATOR 120-8F <br /> MAX MAXIMUM A4.0 PLANS AND ELEVATIONS -- <br /> MECH MECHANICAL A4.1 WIND SCREEN DETAILS <br /> MFR MANUFACTURER fik \ NON CONTINUOUS BLOCKING <br /> NG MIN MINIMUM <br /> MOW MAINTENANCE OF WAY J <br /> 2 TAL ` <br /> N/A NOT APPLICABLE <br /> SHEET NUMBER WHERE THE SEALANT AND BACKER ROD <br /> N/A NO <br /> h NIC NOT IN CONTRACT ELEVATION IS SHOWN <br /> - NO NUMBER <br /> N.T.S NOT TO SCALE <br /> 0/ OVER j GLASS/GLASS BLOCK <br /> OC ON CENTER DETAIL DESIGNATOR <br /> OPNG OPENING <br /> OPP OPPOSITE <br /> ry PET PHONE&TELEPHONE DETAIL TACTILE WARNING TILE <br /> PC PRECAST XXXXX SCALE: <br /> PERF PERFORATED \--/� <br /> PERIM PERIMETER <br /> m PGL PROFILE GRADE LEVEL SHEET NUMBER WHERE THE <br /> .; PLYWD PLYWOOD DETAIL IS SHOWN <br /> o PLAT PLATFORM <br /> PRV PRESSURE REDUCING VALVE <br /> i PT PAINT DETAIL DESIGNATOR <br /> al R RADIUS OR RISER <br /> 8I R- R-VALUE <br /> °,„1 RCP REFLECTED CEILING PLAN DETAIL <br /> REQD REQUIRED SCALE: <br /> RO ROUGH OPENING <br /> SECT SECTION DETAIL SHOWN ON THE <br /> SHT SHEET SAME SHEET ONLY <br /> E Drowing No. <br /> sO, Drawn By Dote SCALECOMMUNITY TRANSITta <br /> r1 MI GROUP REGISTER KC 9/30/19 AO <br /> 1'� 801 Second Avenue—Suite 1000 Cr --o o ARC I PERMIT oes'geed By Holz SEAWAY TRANSIT CENTER — SHELTER NS <br /> I K I Seattle WA 98104 USA c o m m u n i t y t r ar a n 00 9/30/19 NTS Sheet No. <br /> o V tel 206 521 9091 fax 206 521 9095 ,�c GR RY L MILL SET Checked By Vert /d/,9 <br /> Sn�In 1' SIN F wASHINGTON GH 9/30/19 N/A <br /> at 1 1 ibigroup.comApproved By Project Number 1 <br /> O Co. Date Revision By Appr 20110155.016 LEGEND & ABBREVIATIOnS of Total <br />