Laserfiche WebLink
STATEMENT OF STRUCTURAL SPECIAL INSPECTIONS AND TESTING (2015) <br /> TABLE 1 - REQUIRED GEOTECHNICAL SPECIAL INSPECTIONS TABLE 2 CONTINUED- REQUIRED STRUCTURAL SPECIAL INSPECTIONS <br /> INSPECTION INSPECTION <br /> SYSTEM or MATERIAL IBC CODE CODE or STANDARD FREQUENCY(NOTE 6) REMARKS SYSTEM or MATERIAL IBC CODE CODE or STANDARD FREQUENCY(NOTE 6) REMARKS <br /> REFERENCE REFERENCE CONTINUOUS I PERIODIC REFERENCE REFERENCE CONTINUOUSIPERIODIC <br /> SOILS MASONRY-LEVEL B <br /> VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS VERIFICATION OF SLUMP FLOW AND VISUAL TMS 602:TB 4 <br /> ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING X STABILITY INDEX(VSI)AS DELIVERED TO THE TMS 602:1.5 B.1.b.3 X <br /> CAPACITY. PROJECT SITE FOR SELF-CONSOLIDATING GROUT. <br /> VERIFY EXCAVATIONS ARE EXTENDED TO PROPER VERIFICATION OF Pm AND PApo PRIOR TO TMS 602:TB 4 <br /> DEPTH AND HAVE REACHED PROPER MATERIAL. X CONSTRUCTION,EXCEPT WHERE SPECIFICALLY 1705.4 TMS 602:1.4 B X <br /> EXEMPTED BY THE CODE. <br /> VERIFY COMPLIANCE WITH THE APPROVED TMS 602:TB 4(1) X <br /> PERFORM CLASSIFICATION AND TESTING OF X SUBMITTALS TMS 602:1.5 <br /> COMPACTED FILL MATERIALS. TB 1705.6 GEOTECHNICAL BY THE GEOTECHNICAL ENGINEER <br /> 1705.E REPORT AS MASONRY CONSTRUCTION BEGINS,VERIFY THAT THE FOLLOWING ARE IN COMPLIANCE: <br /> VERIFY USE OF PROPER MATERIALS,DENSITIES AND PROPORTIONS OF SITE-PREPARED MORTAR TMS 602:TB 4(2.a) X <br /> LIFT THICKNESSES DURING PLACEMENT AND TMS 602:2.1,2.6 A <br /> X CONSTRUCTION OF MORTAR JOINTS TMS 602.TB 4(2.b) X <br /> COMPACTION OF COMPACTED FILL. TMS 602:3.3 B <br /> 1705.4 <br /> PRIOR TO PLACEMENT OF COMPACTED FILL, LOCATION OF REINFORCEMENT TMS 602:TB 4(2.d) X <br /> OBSERVE SUBGRADE AND VERIFY THAT SITE HAS X AND CONNECTORS TMS 602:3.4 <br /> BEEN PREPARED PROPERLY. <br /> VERIFY DURING CONSTRUCTION: <br /> TYPE,SIZE,AND LOCATION OF ANCHORS, TMS 602:TB 4(4.b) <br /> INCLUDING OTHER DETAILS OF ANCHORAGE ) X <br /> (E.2.1 <br /> TABLE 2 - REQUIRED STRUCTURAL SPECIAL INSPECTIONS OF MASONRY TO STRUCTURAL MEMBERS, 1705.4 TMS 402:TMS 402:6.1.4.3,1 6.2.1 <br /> FRAMES,OR OTHER CONSTRUCTION <br /> INSPECTION <br /> '� SYSTEM or MATERIAL ION <br /> IBC CODE CODE or STANDARD FREQUENCY(NOTE 6) REMARKS SYSTEM or MATERIAL IBC CODE CODE INSPECTION <br /> (NOTE 8) REMARKS <br /> REFERENCE REFERENCE CONTINUOUS I PERIODIC <br /> in REFERENCE REFERENCE OBSERVE 'PERFORM <br /> FABRICATION STEEL <br /> 0 WHERE FABRICATION OF STRUCTURAL <br /> Q V LOAD-BEARING MEMBERS AND ASSEMBLIES IS BEING INSPECTION TASKS PRIOR TO WELDING: <br /> PERFORMED ON THE PREMISES OF A FABRICATOR'S WELDING PROCEDURE SPECIFICATIONS(WPSs) <br /> E INSPECTION IN FABRICATION SHOP 1704.2.5 SHOP,SPECIAL INSPECTION OF THE FABRICATED AVAILABLE AISC 360:TB N5.4-1 X <br /> ITEMS SHALL BE ASREQUIRED ELSEWHERE NRED THE STATEMENT OBY TABLE 2D AS <br /> F MANUFACTURER CERTIFICATIONS FOR WELDING <br /> O SPECIAL INSPECTIONS.REFERENCE SECTION <br /> CONSUMABLES AVAILABLE66 AISC 360:TB N5.4-1 X <br /> 1704.2.5.1 FOR APPROVED FABRICATOR EXCEPTION.tO MATERIAL IDENTIFICATION(TYPE/GRADE) AISC 360:TB N5.4-1 X <br /> C.i CONCRETE <br /> O T81705.3(1) ACI 31820 WELDER IDENTIFICATION SYSTEM AISC 360:TB N5.4-1 X <br /> 0INSPECTION OF REINFORCING STEEL AND <br /> 1705.3 ACI 318 2.2-25.3 X TOLERANCE AND REINFORCING PLACEMENT PER <br /> 1 <br /> PLACEMENT ACI 318 26.6 FIT-UP OF GROOVE WELDS(INCLUDING JOINT <br /> p 1908.4 ACI 318 26.6.1,26.6.3GEOMETRY):JOINT PREPARATION,DIMENSIONS <br /> INSPECTION OF REINFORCING STEEL WELDING TB 1705.3(2) ACI 318 3.5.2 EXCEPT AS NOTED OTHERWISE (ALIGNMENT,ROOT OPENING,ROOT FACE,BEVEL), AISC 360:TB N5.4-1 X <br /> 1705.3.1 AWS D1.4,SECTION 7 CLEANLINESS(CONDITION OF STEEL SURFACES), 1705.2 <br /> TB 1705.2.2 AWS D7.4 TACKING(TACK WELD QUALITY AND LOCATION), <br /> U OTHER REINFORCING STEEL (2.b.4) ACI 318 3.5.2 X BACKING TYPE AND FIT(IF APPLICABLE). -- <br /> 0 CONFIGURATION AND FINISH OF ACCESS HOLES AISC 360:TB N5.4-1 X <br /> WC <br /> ai INSPECT ANCHORS CAST IN CONCRETE 51A 0-1705 ACI 318 D.9.2 X ALL ANCHORS SHALL BE VISUALLY INSPECTED <br /> FIT-UP OF FILLET WELDS:DIMENSIONS <br /> -p (ALIGNMENT,GAPS AT ROOT),CLEANLINESS <br /> INSPECT ANCHORS POST-INSTALLED IN HARDENED (CONDITION OF STEEL SURFACES),TACKING(TACK AISC 360:TB N5.4-1 X <br /> O CONCRETE MEMBERS: WELD QUALITY AND LOCATION),BACKING TYPE <br /> d AND FIT(IF APPLICABLE) <br /> ADHESIVE ANCHORS INSTALLED IN <br /> 0 <br /> HORIZONTALLY OR UPWARDLY INCLINED WAC ICC EVALUATION RPT X REFER TO ANCHOR CALLOUTS FOR SUSTAINED CHECK WELDING EQUIPMENT AISC 360:TB N5.4-1 <br /> D ORIENTATIONS TO RESIST SUSTAINED TENSION 51-50-1705 ACI 31817.8.2.4 ' TENSION(ST)DESIGNATION <br /> N LOADS. INSPECTION TASKS DURING WELDING: <br /> In <br /> UI MECHANICAL ANCHORS AND ADHESIVE ANCHORS WAC ICC EVALUATION RPT X ALL ANCHORS SHALL BE VISUALLY INSPECTED USE OF QUALIFIED WELDERS AISC 360:TB N5.4-2 X <br /> I- NOT DEFINED ABOVE. 51-50-1705 ACI 31817.2 (NOTE 7) <br /> jCONTROL AND HANDLING OF WELDING AISC 360:TB N5.4-2 X <br /> rn TB 1705.3(5) CONSUMABLES:PACKAGING,EXPOSURE CONTROL <br /> a) 1705.3 ACI 318 26.3 . <br /> O - VERIFYING USE OF REQUIRED DESIGN MIX. 1904 ACI 318 19 X NO WELDING OVER CRACKED TACK WELDS AISC 360:TB N5.4-2 X <br /> O c 1908.2 ACI 31626.4.3-26.4.4 ENVIRONMENTAL CONDITIONS:WIND SPEED <br /> 0 1908.3 - WITHIN LIMITS,PRECIPITATION AND TEMPERATURE AISC 360:TB N5.4-2 X <br /> CD O PRIOR TO CONCRETE PLACEMENT TO FABRICATE ASTM C 172 WPS FOLLOWED:SETTINGS ON WELDING 1705.2 <br /> SPECIMENS FOR STRENGTH TEST,PERFORM SLUMP TB 1705.3(6)0 AND AIR CONTENT TESTS,AND DETERMINE THE 1908.10 ASTM C 31 X EQUIPMENT,TRAVEL SPEED,SELECTED WELDING <br /> ACI 318 26.4,26.12 MATERIALS,SHIELDING GAS TYPE/FLOW RATE, <br /> TEMPERATURE OF THE CONCRETE. PREHEAT APPLIED,INTERPASS TEMPERATURE AISC 360:TB N5.4-2 X <br /> • O MAINTAINED(MIN./MAX.),PROPER POSITION(F,V, <br /> H,OH) <br /> U7 N WELDING TECHNIQUES:INTERPASS AND FINAL <br /> O o CLEANING,EACH PASS WITHIN PROFILE AISC 360:TB N5.4-2 X <br /> 0 LIMITATIONS,EACH PASS MEETS QUALITY <br /> O U REQUIREMENTS <br /> -o INSPECTION TASKS AFTER WELDING: <br /> -p J <br /> Q J <br /> Q WELDS CLEANED AISC 360:TB N5.4-3 X <br /> X <br /> O O <br /> S m SIZE,LENGTH AND LOCATION OF WELDS AISC 360:TB N5.4-3 X <br /> N U <br /> (n WELDS MEET VISUAL ACCEPTANCE CRITERIA: .. , .. <br /> CRACK PROHIBITION,WELD/BASE-METAL FUSION, AISC 360:TB N5.4-3 X <br /> CRATER CROSS SECTION,WELD PROFILES,WELD <br /> 1 O] SIZE,UNDERCUT,POROSITY 1705.2 - <br /> r <br /> O U ARC STRIKES AISC 360:TB N5.4-3 X - - <br /> O F, <br /> O /n <br /> OT <br /> _ REPAIR ACTIVITIES AISC 360:TB N5.4-3 X <br /> O N DOCUMENT ACCEPTANCE OR REJECTION OF <br /> O N AISC 360:TB N5.4-3 X <br /> N '- WELDED JOINT OR MEMBER <br /> Oa <br /> I <br /> Qj Drawing No. <br /> OMj o 16015thAvenue, /O 0 °s r By Date SCALE COMMUNITY TRANSIT <br /> E 1 SHi c Dawn <br /> Suite1600 0 "-o i ( l Designed <br /> 1/5/2017 SEAWAY TRANSIT CENTER S2 <br /> COIiClM711�#1ltytCa , _ �r BID SET Designed By Ha z <br /> Seattle,WA 98101 t GLS 1/5/2017 <br /> ` �7�� Checked By Vert Sheet No. <br /> 206.622.6822 sroila&[tnsit "� ��v. JOS 1/5/2017 <br /> 1 10/14/19 ADDITIONAL BUS SHELTERS JNC COO www.kpff.com ,, ecry7es y ApprovedX <br /> '°�� ' �•A1` CDO 1/5/2017 Pro 1900675�r SPECIAL INSPECTIONS X <br /> o X No. Date Revision By MPr v0 - - of Total <br />