STATEMENT OF STRUCTURAL SPECIAL INSPECTIONS AND TESTING (2015)
<br /> TABLE 1 - REQUIRED GEOTECHNICAL SPECIAL INSPECTIONS TABLE 2 CONTINUED- REQUIRED STRUCTURAL SPECIAL INSPECTIONS
<br /> INSPECTION INSPECTION
<br /> SYSTEM or MATERIAL IBC CODE CODE or STANDARD FREQUENCY(NOTE 6) REMARKS SYSTEM or MATERIAL IBC CODE CODE or STANDARD FREQUENCY(NOTE 6) REMARKS
<br /> REFERENCE REFERENCE CONTINUOUS I PERIODIC REFERENCE REFERENCE CONTINUOUSIPERIODIC
<br /> SOILS MASONRY-LEVEL B
<br /> VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS VERIFICATION OF SLUMP FLOW AND VISUAL TMS 602:TB 4
<br /> ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING X STABILITY INDEX(VSI)AS DELIVERED TO THE TMS 602:1.5 B.1.b.3 X
<br /> CAPACITY. PROJECT SITE FOR SELF-CONSOLIDATING GROUT.
<br /> VERIFY EXCAVATIONS ARE EXTENDED TO PROPER VERIFICATION OF Pm AND PApo PRIOR TO TMS 602:TB 4
<br /> DEPTH AND HAVE REACHED PROPER MATERIAL. X CONSTRUCTION,EXCEPT WHERE SPECIFICALLY 1705.4 TMS 602:1.4 B X
<br /> EXEMPTED BY THE CODE.
<br /> VERIFY COMPLIANCE WITH THE APPROVED TMS 602:TB 4(1) X
<br /> PERFORM CLASSIFICATION AND TESTING OF X SUBMITTALS TMS 602:1.5
<br /> COMPACTED FILL MATERIALS. TB 1705.6 GEOTECHNICAL BY THE GEOTECHNICAL ENGINEER
<br /> 1705.E REPORT AS MASONRY CONSTRUCTION BEGINS,VERIFY THAT THE FOLLOWING ARE IN COMPLIANCE:
<br /> VERIFY USE OF PROPER MATERIALS,DENSITIES AND PROPORTIONS OF SITE-PREPARED MORTAR TMS 602:TB 4(2.a) X
<br /> LIFT THICKNESSES DURING PLACEMENT AND TMS 602:2.1,2.6 A
<br /> X CONSTRUCTION OF MORTAR JOINTS TMS 602.TB 4(2.b) X
<br /> COMPACTION OF COMPACTED FILL. TMS 602:3.3 B
<br /> 1705.4
<br /> PRIOR TO PLACEMENT OF COMPACTED FILL, LOCATION OF REINFORCEMENT TMS 602:TB 4(2.d) X
<br /> OBSERVE SUBGRADE AND VERIFY THAT SITE HAS X AND CONNECTORS TMS 602:3.4
<br /> BEEN PREPARED PROPERLY.
<br /> VERIFY DURING CONSTRUCTION:
<br /> TYPE,SIZE,AND LOCATION OF ANCHORS, TMS 602:TB 4(4.b)
<br /> INCLUDING OTHER DETAILS OF ANCHORAGE ) X
<br /> (E.2.1
<br /> TABLE 2 - REQUIRED STRUCTURAL SPECIAL INSPECTIONS OF MASONRY TO STRUCTURAL MEMBERS, 1705.4 TMS 402:TMS 402:6.1.4.3,1 6.2.1
<br /> FRAMES,OR OTHER CONSTRUCTION
<br /> INSPECTION
<br /> '� SYSTEM or MATERIAL ION
<br /> IBC CODE CODE or STANDARD FREQUENCY(NOTE 6) REMARKS SYSTEM or MATERIAL IBC CODE CODE INSPECTION
<br /> (NOTE 8) REMARKS
<br /> REFERENCE REFERENCE CONTINUOUS I PERIODIC
<br /> in REFERENCE REFERENCE OBSERVE 'PERFORM
<br /> FABRICATION STEEL
<br /> 0 WHERE FABRICATION OF STRUCTURAL
<br /> Q V LOAD-BEARING MEMBERS AND ASSEMBLIES IS BEING INSPECTION TASKS PRIOR TO WELDING:
<br /> PERFORMED ON THE PREMISES OF A FABRICATOR'S WELDING PROCEDURE SPECIFICATIONS(WPSs)
<br /> E INSPECTION IN FABRICATION SHOP 1704.2.5 SHOP,SPECIAL INSPECTION OF THE FABRICATED AVAILABLE AISC 360:TB N5.4-1 X
<br /> ITEMS SHALL BE ASREQUIRED ELSEWHERE NRED THE STATEMENT OBY TABLE 2D AS
<br /> F MANUFACTURER CERTIFICATIONS FOR WELDING
<br /> O SPECIAL INSPECTIONS.REFERENCE SECTION
<br /> CONSUMABLES AVAILABLE66 AISC 360:TB N5.4-1 X
<br /> 1704.2.5.1 FOR APPROVED FABRICATOR EXCEPTION.tO MATERIAL IDENTIFICATION(TYPE/GRADE) AISC 360:TB N5.4-1 X
<br /> C.i CONCRETE
<br /> O T81705.3(1) ACI 31820 WELDER IDENTIFICATION SYSTEM AISC 360:TB N5.4-1 X
<br /> 0INSPECTION OF REINFORCING STEEL AND
<br /> 1705.3 ACI 318 2.2-25.3 X TOLERANCE AND REINFORCING PLACEMENT PER
<br /> 1
<br /> PLACEMENT ACI 318 26.6 FIT-UP OF GROOVE WELDS(INCLUDING JOINT
<br /> p 1908.4 ACI 318 26.6.1,26.6.3GEOMETRY):JOINT PREPARATION,DIMENSIONS
<br /> INSPECTION OF REINFORCING STEEL WELDING TB 1705.3(2) ACI 318 3.5.2 EXCEPT AS NOTED OTHERWISE (ALIGNMENT,ROOT OPENING,ROOT FACE,BEVEL), AISC 360:TB N5.4-1 X
<br /> 1705.3.1 AWS D1.4,SECTION 7 CLEANLINESS(CONDITION OF STEEL SURFACES), 1705.2
<br /> TB 1705.2.2 AWS D7.4 TACKING(TACK WELD QUALITY AND LOCATION),
<br /> U OTHER REINFORCING STEEL (2.b.4) ACI 318 3.5.2 X BACKING TYPE AND FIT(IF APPLICABLE). --
<br /> 0 CONFIGURATION AND FINISH OF ACCESS HOLES AISC 360:TB N5.4-1 X
<br /> WC
<br /> ai INSPECT ANCHORS CAST IN CONCRETE 51A 0-1705 ACI 318 D.9.2 X ALL ANCHORS SHALL BE VISUALLY INSPECTED
<br /> FIT-UP OF FILLET WELDS:DIMENSIONS
<br /> -p (ALIGNMENT,GAPS AT ROOT),CLEANLINESS
<br /> INSPECT ANCHORS POST-INSTALLED IN HARDENED (CONDITION OF STEEL SURFACES),TACKING(TACK AISC 360:TB N5.4-1 X
<br /> O CONCRETE MEMBERS: WELD QUALITY AND LOCATION),BACKING TYPE
<br /> d AND FIT(IF APPLICABLE)
<br /> ADHESIVE ANCHORS INSTALLED IN
<br /> 0
<br /> HORIZONTALLY OR UPWARDLY INCLINED WAC ICC EVALUATION RPT X REFER TO ANCHOR CALLOUTS FOR SUSTAINED CHECK WELDING EQUIPMENT AISC 360:TB N5.4-1
<br /> D ORIENTATIONS TO RESIST SUSTAINED TENSION 51-50-1705 ACI 31817.8.2.4 ' TENSION(ST)DESIGNATION
<br /> N LOADS. INSPECTION TASKS DURING WELDING:
<br /> In
<br /> UI MECHANICAL ANCHORS AND ADHESIVE ANCHORS WAC ICC EVALUATION RPT X ALL ANCHORS SHALL BE VISUALLY INSPECTED USE OF QUALIFIED WELDERS AISC 360:TB N5.4-2 X
<br /> I- NOT DEFINED ABOVE. 51-50-1705 ACI 31817.2 (NOTE 7)
<br /> jCONTROL AND HANDLING OF WELDING AISC 360:TB N5.4-2 X
<br /> rn TB 1705.3(5) CONSUMABLES:PACKAGING,EXPOSURE CONTROL
<br /> a) 1705.3 ACI 318 26.3 .
<br /> O - VERIFYING USE OF REQUIRED DESIGN MIX. 1904 ACI 318 19 X NO WELDING OVER CRACKED TACK WELDS AISC 360:TB N5.4-2 X
<br /> O c 1908.2 ACI 31626.4.3-26.4.4 ENVIRONMENTAL CONDITIONS:WIND SPEED
<br /> 0 1908.3 - WITHIN LIMITS,PRECIPITATION AND TEMPERATURE AISC 360:TB N5.4-2 X
<br /> CD O PRIOR TO CONCRETE PLACEMENT TO FABRICATE ASTM C 172 WPS FOLLOWED:SETTINGS ON WELDING 1705.2
<br /> SPECIMENS FOR STRENGTH TEST,PERFORM SLUMP TB 1705.3(6)0 AND AIR CONTENT TESTS,AND DETERMINE THE 1908.10 ASTM C 31 X EQUIPMENT,TRAVEL SPEED,SELECTED WELDING
<br /> ACI 318 26.4,26.12 MATERIALS,SHIELDING GAS TYPE/FLOW RATE,
<br /> TEMPERATURE OF THE CONCRETE. PREHEAT APPLIED,INTERPASS TEMPERATURE AISC 360:TB N5.4-2 X
<br /> • O MAINTAINED(MIN./MAX.),PROPER POSITION(F,V,
<br /> H,OH)
<br /> U7 N WELDING TECHNIQUES:INTERPASS AND FINAL
<br /> O o CLEANING,EACH PASS WITHIN PROFILE AISC 360:TB N5.4-2 X
<br /> 0 LIMITATIONS,EACH PASS MEETS QUALITY
<br /> O U REQUIREMENTS
<br /> -o INSPECTION TASKS AFTER WELDING:
<br /> -p J
<br /> Q J
<br /> Q WELDS CLEANED AISC 360:TB N5.4-3 X
<br /> X
<br /> O O
<br /> S m SIZE,LENGTH AND LOCATION OF WELDS AISC 360:TB N5.4-3 X
<br /> N U
<br /> (n WELDS MEET VISUAL ACCEPTANCE CRITERIA: .. , ..
<br /> CRACK PROHIBITION,WELD/BASE-METAL FUSION, AISC 360:TB N5.4-3 X
<br /> CRATER CROSS SECTION,WELD PROFILES,WELD
<br /> 1 O] SIZE,UNDERCUT,POROSITY 1705.2 -
<br /> r
<br /> O U ARC STRIKES AISC 360:TB N5.4-3 X - -
<br /> O F,
<br /> O /n
<br /> OT
<br /> _ REPAIR ACTIVITIES AISC 360:TB N5.4-3 X
<br /> O N DOCUMENT ACCEPTANCE OR REJECTION OF
<br /> O N AISC 360:TB N5.4-3 X
<br /> N '- WELDED JOINT OR MEMBER
<br /> Oa
<br /> I
<br /> Qj Drawing No.
<br /> OMj o 16015thAvenue, /O 0 °s r By Date SCALE COMMUNITY TRANSIT
<br /> E 1 SHi c Dawn
<br /> Suite1600 0 "-o i ( l Designed
<br /> 1/5/2017 SEAWAY TRANSIT CENTER S2
<br /> COIiClM711�#1ltytCa , _ �r BID SET Designed By Ha z
<br /> Seattle,WA 98101 t GLS 1/5/2017
<br /> ` �7�� Checked By Vert Sheet No.
<br /> 206.622.6822 sroila&[tnsit "� ��v. JOS 1/5/2017
<br /> 1 10/14/19 ADDITIONAL BUS SHELTERS JNC COO www.kpff.com ,, ecry7es y ApprovedX
<br /> '°�� ' �•A1` CDO 1/5/2017 Pro 1900675�r SPECIAL INSPECTIONS X
<br /> o X No. Date Revision By MPr v0 - - of Total
<br />
|