Laserfiche WebLink
CITY OF EVERETT SPECIAL PROVISIONS <br /> Provide an affidavit of compliance stating the valve furnished fully complies with AWWA <br /> C509 or AWWA C515. <br /> 9-30.3(3) Butterfly Valves <br /> Revise the first sentence of the second paragraph of 9-30.3(3) to read as follows: <br /> Valve operators shall be of the travelling nut, self-locking type, sealed, gasketed <br /> and permanently lubricated for underground service. <br /> 9-30.3(4) Valve Boxes <br /> Supplement 9-30.3(4) by adding the following: <br /> ' Provide East Jordan 8555 Series, two piece slip type box with 6800 two and one- <br /> half inch skirt drop lid or City approved equal. <br /> Plastic valve boxes with a cast iron lid having dimensions conforming to a number <br /> 940 valve box, as manufactured by Handley Industries, or City approved equal, <br /> are acceptable for valve boxes located in grass, non-paved or paved non- <br /> vehicular traffic areas. <br /> 9-30.3(5) Valve Marker Posts <br /> Delete first and second paragraphs of 9-30.3(5) and substitute the following: <br /> Post shall be 4-inch diameter, 42-inch tall, fluorescent orange, low density <br /> polypropylene portable traffic delineator post with two reflectorized strips. <br /> 9-30.3(6) Valve Stem Extension <br /> Revise the first paragraph of 9-30.3(6) to read as follows: <br /> Provide valve stem extension in accordance with COE Standard Drawing No. 504. <br /> 9-30.3(7) Combination Air Release/Air Vacuum Valves <br /> Supplement this section by adding the following. <br /> Provide combination air release/air vacuum valve in accordance with COE <br /> Standard Drawing 512, parts list modified to provide size 2-inch instead of 1" <br /> parts. Locate at the high point in the main and tap at the top of the main. <br /> 9-30.3(8) Tapping Sleeve and Valve Assembly <br /> ' Revise the last sentence of 9-30.3(8) to read as follows: <br /> Provide all stainless steel tapping sleeves, Romac SST, Romac SSTIII, or City <br /> approved equal. <br /> 9-30.5 Hydrants <br /> Delete first paragraph of 9-30.5 and substitute the following: <br /> Provide fire hydrants with ANSI 125 flanged connection conforming to AWWA C502. <br /> Provide Mueller "Super Centurion No. 250", American Flow Control "Waterous Pacer <br /> No. WB67", or City approved equal. <br /> 9-30.5(2) Hydrant Dimensions <br /> Delete last sentence of first paragraph of 9-30.5(2) and substitute the following: <br /> Provide hydrants having two 2-1/2 inch hose nozzles and one 4-1/2 inch pumper <br /> nozzle. The 4-1/2 inch pumper nozzle shall be National Thread and fitted with a <br /> 5-inch STORZ fitting. <br /> Delete last sentence of second paragraph of 9-30.5(2) and substitute the following: <br /> Paint hydrants with two coats of high gloss Caterpillar yellow, Luxite 6100-516, <br /> Rost-Oleum 7448, or City approved equal. Paint the port caps with two coats of <br /> high gloss black enamel paint. <br /> ' 9-30.5(4) Hydrant Restraints <br /> Revise the first paragraph of 9-30.5(4) to read as follows: <br /> Watermain Replacement"V" Division 9—MATERIALS April, 2021 <br /> WO No.—UP3730 SP—205 ADDENDUM#1 <br />