Thomco Construction Inc. 6/14/2021
>
Contracts
>
Capital Contract
>
Thomco Construction Inc. 6/14/2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2022 10:53:29 AM
Creation date
6/18/2021 10:03:52 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Thomco Construction Inc.
Approval Date
6/14/2021
Council Approval Date
5/19/2021
Department
Public Works
Department Project Manager
Amie Roshak
Subject / Project Title
Water Main Replacement V
Public Works WO Number
UP3730
Tracking Number
0002953
Total Compensation
$1,924,004.26
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
Thomco Construction Inc. 6/22/2022 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
492
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NE - M M NM M ! M M M M MI M MN 0 E MO <br /> I I <br /> BROOM FINISH ALL BROOM FINISH ALL O NOTES <br /> SURFACES BEFORE 0 SURFACES BEFORE <br /> SMOOTH TROWELING SMOOTH TROWELING 1. DETECTABLE WARNING PATTERN AREA SHALL BE <br /> EDGES AND JOINTS 0 © EDGES AND JOINTS YELLOW IN COMPLIANCE WITH WSDOT/APWA <br /> STANDARD SPECIFICATION SECTION 8-14.3(3). <br /> B 4-1 <br /> BACK OF S/W 2. CURB RAMPS SHALL NOT BE POURED INTEGRAL <br /> WITH SIDEWALK AND SHALL BE ISOLATED FROM <br /> A A ADJACENT SIDEWALK BY AB <br /> 3/8"FULL DEPTH <br /> EXPANSION JOINT. <br /> L1:12 MAX N JI 1:12 MAX 1 3. GUTTER SECTION AT CURB RAMP SHALL NOT BE <br /> POURED INTEGRAL WITH ADJACENT GUTTER <br /> N iijiiiiill(lii�jii= ;itir N SECTIONS AND SHALL BE ISOLATED BY A 3/8"FULL <br /> t.t==. DEPTH EXPANSION JOINT. <br /> / . ......... ........i.lt..: <br /> _ 4. CURB RAMP AND GUTTER SECTION AT CURB RAMP <br /> RAMP 6'LANDING RAMP MAY BE POURED AS AN INTEGRAL SECTION. <br /> 6'MIN 6'MIN 5. TYPE A-1 INTEGRAL CURB AND GUTTER PER CITY <br /> B 4-1 O 6. FOR RETROFIT INSTALLATION SAWCUT AND <br /> 0 REMOVE EXISTING SIDEWALK,CURB AND GUTTER <br /> / PLAN SECTION ALONG NEW EXPANSION JOINT <br /> CROSSWALK SEE O O LOCATION.SAWCUT EXISTING PAVEMENT AS <br /> STANDARD DRAWING 721 0REQUIRED FOR FORMING OF NEW CURB AND <br /> GUTTER.PATCH PAVEMENT AS REQUIRED. <br /> 7. FLUSH WITH GUTTER(NO LIP PERMITTED) <br /> 8. A MIN OF 4'OF THE RAMP WIDTH MUST FALL <br /> RAMP 6'MIN _ 6'MIN RAMP 6'MIN WITHIN THE CROSS WALK SERVED BY THE RAMP. <br /> 0 0 LANDING <br /> 9. THICKEN EDGE TO FULL DEPTH OF ADJACENT CURB <br /> io 'al SECTION. <br /> SECTION A—A A { <br /> ,, 0 I <br /> 6'MIN CL <br /> LANDING I g RAMP <br /> 0 I1 <br /> t <br /> MIN MAX a 11 9:I- <br /> LI <br /> ° i B 155/8 2-1 2" �mLI + ©i <br /> 2%MAX B 5 8" 1-1 2" I. <br /> o �� o D 7/8" 1 7/16" <br /> D CITY OF EVERETT <br /> 0 0 0 <br /> 1-I PUBLIC WORKS DEPARTMENT <br /> M <br /> p <br /> Oa —RYAN SASSITOMHOOD I pFAULWILHELM Id�WRB D 21/2018 <br /> > SECTION B B DETECTABLE WARNING PATTERN <br /> IS" <br /> TYPE C CURB RAMP 320Me <br /> IcS <br /> 1 I— - <br />
The URL can be used to link to this page
Your browser does not support the video tag.