My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Thomco Construction Inc. 6/14/2021
>
Contracts
>
Capital Contract
>
Thomco Construction Inc. 6/14/2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2022 10:53:29 AM
Creation date
6/18/2021 10:03:52 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Thomco Construction Inc.
Approval Date
6/14/2021
Council Approval Date
5/19/2021
Department
Public Works
Department Project Manager
Amie Roshak
Subject / Project Title
Water Main Replacement V
Public Works WO Number
UP3730
Tracking Number
0002953
Total Compensation
$1,924,004.26
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
Thomco Construction Inc. 6/22/2022 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
492
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I I <br /> UTILITY VAULT CO. PARTS NOTES <br /> SIZE MODEL COVER <br /> 21/2' 644 64-2-332P 0 POST INDICATOR VALVE(Ply)PAINTED RED WITH TAMPER TO FIRE ALARM PANEL 1. TEE AND GATE VALVE REQUIRED ON MAIN. <br /> 3' 644 64-2-332P 18"X18"X8" AND WITH STENCILED ADDRESS(WHITE,2"HIGH TEXT). <br /> 4' 575 57TL-2-332P CONC.BLOCK 2. SINGLE DETECTOR CHECKS ARE NOT <br /> 6' 577 57TL-2-332P O DUCTILE IRON PIPE(SIZED AS REQUIRED)CLASS 52. APPROVED BACKFLOW PREVENTION DEVICES. <br /> 8' 4484 4484-TL2-332P <br /> 10' 5106 5106-TL3-332 .. <br /> i O SCHEDULE 40 GALV.STEEL WRAPPED W/6MIL PLASTIC. 3. ASSEMBLY REQUIRES CERTIFICATION UPON <br /> slo' INSTALLATION AND RE-CERTIFICATION <br /> _ 0CLASS 52 DI TEE FL X FL. ANNUALLY BY OWNER. <br /> 0 © O O SWING CHECK VALVE W/BALL DRIP ASSEMBLY. 4. ALL TEST COCKS MUST HAVE BRASS PLUGS. <br /> © O FIRE DEPARTMENT CONNECTION(FDC),BRASS.PROVIDE KNOX LOCKING CAPS. 5. ROUND MANHOLE LIDS ARE NOT TO BE USED. <br /> ( _ EXPOSED GALVANIZED STEEL PIPE TO BE PAINTED RED.STENCIL ADDRESS(WHITE, <br /> B II l('I i; B 2"HIGH TEXT)ON PAINTED PIPE. 6. INSIDE DEPTH IS TO BE KEPT AT A MINIMUM <br /> 0 <br /> 7 I ♦ © ,_ ♦O 07. ALL PIPE THROUGH VAULT WALL SHALL BE CORE DRILLED AND HAVE A"LINK SEAL"(OR APPROVED EQUAL). AS PER DIMENSION IN SKETCHES ABOVE <br /> AND/OR AS APPROVED BY CITY OF EVERETT <br /> BUILDING UTILITIES DEPARTMENT. <br /> �� �� 8 OS&Y VALVES WITH TAMPER SWITCH TO ALARM PANEL OR CHAIN AND PADLOCK. <br /> ��� _ ��� �'II= 9. 1-GALV.LADDER WITH PULL-UP LADDER EXTENSION TO BE BOLTED TO VAULT 7. METER SHALL BE <br /> CAN BE READ WITH INSTALLED <br /> ACCESS SUCHHATC THAT <br /> OPE IT <br /> — FLOOR AND TO VAULT WALL,MOUNTED SUCH THAT LADDER IS DIRECTLY ABOVE AND WITHOUT ENTERING THE VAULT. <br /> I®hlolohl 0- 0 THE EDGE OF ACCESS OPENING FOR EASE OF ACCESS. <br /> A I I TAMPER A 10 UL-FM LISTED SOFTSEATED WA STATE APPROVED DOUBLE CHECK DETECTOR 8. ALL DIMENSIONS ARE MINIMUM CLEARANCE. <br /> 1 SWITCH IF VALVE ASSEMBLY INCLUDING 2-O.S.&Y RESILIENT SEATED GATE VALVES,TEST <br /> - -- ) © REQUIRED? COCKS,3/4"BRASS OR COPPER BYPASS WITH INLINE VALVES,5/8"X 3/4" IN A VAULT OUTSIDE THE BUILDING UNLESS <br /> NEPTUNE METER W/E-CODER R900 I,CU FT W/STUB ANTENNA&A 3/4"DOUBLE g ALL BACKFLOW DEVICES WILL BE INSTALLED <br /> CHECK VALVE ASSEMBLY. OTHERWISE APPROVED BY UTILITIES <br /> SUPERINTENDENT. <br /> PLAN 11 STATE APPROVED DOUBLE CHECK DETECTOR ASSEMBLY. <br /> 10. FIRE SERVICE PIPINGS FROM MAIN TO <br /> RAISED ® <br /> RFCA(RESTRAINED FLANGE COUPLING ADAPTER). BUILDING SHALL BE RESTRAINED. <br /> @ CUTABLE PADLOCK WITH KEY IN KNOX BOX. <br /> O LETTERS _ 11. PROVISIONS FOR DRAINAGE OF THE VAULT <br /> "AUTO I MM TAMPER SHALL BE IN THE FOLLOWING ORDER OF <br /> O SPRINKLER" SWITCH IF ( �(O PRECEDENCE: <br /> ®I, DUAL 2-1/2"FEMALE FIRE DEPT <br /> .i. REQUIRED 0 <br /> ` + INLET CONNECTION BRASS(NOT A)VAULT DRAIN TO DAYLIGHT <br /> I PAINTED)"AUTO SPRINKLER" B)VAULT DRAIN TO STORM DRAIN SYSTEM <br /> TAMPER I" m N (IF PRACTICAL) <br /> SWITCH STENCILED 18"X18"X8" SCHEDULE 40 GALVANIZED STEEL C)IF NO POSSIBLE MEANS OF GRAVITY DRAIN, <br /> ADDRESS TO CONC.BLOCK PAINTED RED,STENCILED ADDRESS THEN INSTALL SUMP PUMP <br /> . —FACE STREET PAINTED WHITE 12. SWING CHECK VALVE ON FDC LINE MUST BE <br /> _-- -- .-- .1111- LOCATED IN A VAULT. IF OUTSIDE OF DCDA <br /> o VAULT,MUST BE IN MINIMUM 4'X4'VAULT. <br /> N RI -_—, l SCHEDULE40 <br /> GALVANIZED STEELP 13. PIV LOCATION MUST BE DOWNSTREAM OF <br /> roe.. .I�II i WRAPPED WITH 6 DCDA AND UPSTREAM OF FDC. <br /> I MIL PLASTIC II <br /> © 14. NEW FDC MUST BE LOCATED WITHIN 75'OF A <br /> II , © I FIRE HYDRANT (OR 100'FOR AN EXISTING <br /> F iph 0 BUILDING BEING RETROFIT FOR SPRINKLERS). <br /> LO:o O --- <br /> 1_ ii, xi <br /> Ojjrijl <br /> NEW FIRE HYDRANT INSTALLATION MAY BE <br /> NEEDED TO MEET CODE REQUIREMENT <br /> a 0 <br /> 0 <br /> 0 <br /> TYPICAL WHEN FIRE ROOM IS MORE THAN 70'FROM MAIN <br /> I -' <br /> O ti PROVIDE 9"MINIMUM AND 12"MAXIMUM ` EVERETT PUBLIC WORKS <br /> 2. DEPARTMENTF WASHINGTON <br /> OF BACFLOASSEMBLY. WHERE ELEVATION OF <br /> ,I�POSITIVE VAULT DRAIN VAULT FLOOR IS TOO LOW TO DRAIN TO DAYLIGHT "``RVAHSASS IRR.I0 I PAUI WILHELM 1""'R "7Z/ O20 <br /> OR STORM SYSTEM,MUST HAVE 6"FLOOR <br /> OPENING FOR DRAINAGE(APPROVED BY THE CITY DOUBLE CHECK DETECTOR "'"°""°"'""`"' <br /> Is DCDVA ELEVATION A-A ENGINEER ONACASEBYCASEBASISONLY). FDC ELEVATION B-B VALVE ASSEMBLY W/FDC& PIV 515 <br /> . (DCDA)2"&LARGER SERVICE <br /> I - - I <br /> L <br /> MI r I — M r — NM M M ..a NM In W r M — M NM <br />