► � .�`�' <br /> DWS5 <br /> Building B, Suite 100 <br /> 6617 Associatetl BNd <br /> Everett, WA 98203 <br /> � <br /> 4 5 6 7 w <br /> � <br /> - 5�•-0• `A�-0� 42�.6� z <br /> JANITOR'S MOTHER'S <br /> CLOSET ROOM - - - - -.. -- -- - - -- - - - - W <br /> U 660 666 ' ` <br /> V <br /> - - Z <br /> TRAINING OPEN O <br /> ROOM .io� -o^ +io• - ^ WORKROOM <br /> fi56 1 <br /> +10' -0' �3 r <br /> ' +10� - 0„ � • <br /> CIRCUL TION <br /> � 61 VESTIBULE � � <br /> ssa � m <br /> +io' - o" <br /> , . +8� _q�� � L.V. <br /> LOCKERS HR <br /> BREAK sss o o ssz o p � <br /> ROOM � . �: +io o' �/� <br /> O 669 .. 3�, +10' - " +10' 0" +SO 0" G > �/ ! <br /> +10' -0" 21 " :: . Q <br /> iosio - � �1 ' STATI N CONFERENCE O <br /> 1 WOMENS ' �'+5 5 MENS � MANA ER ROOM �/ <br /> � RESTROOM 4 RESTROOM'�� �� �i I LJ� � <br /> sss : ssa - � � � � � �O <br /> +8 4 �_, +9 6 : � ` /r m r � . <br /> �, �3 , � �q •.: � �V O <br /> �::s "� � N <br /> +8 4" g^+9 6 � ' � � �'^ � <br /> k-� � <br /> EEI B,'Ql. 6A1 ' ��'��F.�1 � ?b��3" . � EP . , r:Ei� aA�§ ;�, I I � � � v, � <br /> :: , z w � m <br /> _ � <br /> � 31 VESTIBULE ° Q � (D � <br /> � �� � � RR � Q C � <br /> � ios.m I s5s I I <br /> I I I � w > � � > <br /> � W c� mw <br /> oescRiariaN o ���. onre <br /> ISSUEFORPERMIT �6�12W0 <br /> n„n � OFFICE REFLECTED CEILING PLAN <br /> �� � SCALE: 1/S" = 1'-0" � <br /> LEGEND CEILING KEY NOTES REFLECTED CEILING PLAN GENERAL NOTES <br /> 301 . E� 1. REFERALSOTODESIGNCRITERIADOCUMENTFORADDITIONAIINFORMATION. <br /> 1e� INTERNALLY ILLUMINATEO EXIT SIGNAGE WI BATTERV BACKUP PER IBC 2. THIS REFLECTEO CEILING PLAN IS PROVIDED TO DOCOMENT CEILING DESIGN <br /> SECTION1013, CONFIRMOPERHTIONFOREXISTING.A�� NMERENOT 302. BATTINSULATIONABOVECEILINGTHISROOM. INTENT. SEEALSOMECHANICALAN� ELECTRICALDOCUMENTATIONFORGOMPLETE � <br /> EXISTING. PRRO W= DIRECTION IN�ICATOR. IF REOUIRED MFORMATION INCLUDING SIMTCH LOCATION, CIRCUITING AND WIRMG LNVOUT. ALL <br /> 303. GWB HEADER MERFP OEVICE LOCATIONS NOT SHOWN ON DRAlMNGS, OR IN CONFLICT WITH <br /> � 2x4 RECESSEO LE� LIGHT Fl%NRE- BA515 OF DESIGW. METALUX, ACCORD. MEPIFP �RAWINGS,ARE TO BE COOR�INATED WITH ARCHITECT PRIOR TO <br /> 3500K, CCT, 85 CRI, 49 WATTS INSTALLATION. IN THE EVENT OF DISLREPANCIES BETWEEN THE ARCHITECTS <br /> 304. LIGHT FIXTURE ON DIMMER REFLECTE�CEILING PLAN AND THE ENGINEERS' PLANS, IMMEDIATELY NOTIFV THE <br /> � ARCHITECT IN WRITING BEFORE ORDERMG MATERIALS OR PRW EEDING WITH THE <br /> 2x4 RECESSE� LEO LIGHT FIXTURE- BA515 OF DESIGN'. METALUX, ACCORD, YWRK. <br /> asoorc, ccr, escRi, 4e wnrrs 305. CEILING MOUNTED PROJECTOR; DISTANCE FROM SCREEN PER <br /> MANUFACTURER'S RECOMMENDATION. PROVIDE POWER AND <br /> o s• Recesseo �e000v�ucHrFixruRe - ensisoFoesicN�. nn�o, s•, MeowM DATAWI7HFLEXIBLECONDUITWHIPABOVECEILING. PROVIDE <br /> �ISTRIBIITIONSPECULARTRIM, HIGHLUMEN, eOCRIl2500K, CCT BACKINGFORMOUNTWG. <br /> � 306. <br /> SUSPENDEO ACOUSTIC CEILING TILE AND GRIO: 24"X 48"SQUARE LAV-IN TILE <br /> 307. WALLMOUNTEDMAINTENANCEANDONINDICATORW/ WALL REFLECTED CONSTRUCTION EXPECTATIONS <br /> � SWITCH @ ROOM ENTRY; 3 LIGHT, 3 SETTING, SEE ELEVATIONS. 100fi <br /> GVVH: GVPSUM BOAR� CEILING - PAINT PT-29 <br /> 308. , <br /> �� 1. GC TO CONTACT CITV LIGHTING PRODUCTS FOR ALL LIGHTING. ALL LIGHTWG 6. PROVIDE SMOKE DETECTORS THROUGHOUT TENANTAREAS IN NCCORDHNCE IMTH 14. NMEN MULTIPLE SWITCHES OGGUR IN CLOSE Pft0%IMI`1'. GANG UN�ER SINGLE 23. PROVIDE CEILING ACGE55 AS RE4. FOR SVSTEMS MAINTENANCE MATCH A�J. <br /> � OPEN TO STRUCTURE FlXTURES AND LIGHT GONTROL PANELS SHALL BE SOURCE� EXCLUSNELV LOCAL COOESAND MANUFACTURER'S RECOMMENDATIONS. SWITCH PLATE CEILING FINISH, UNO. SVSTEMS AN� E�PTTO BE LOCATEO ABOVE ACCESSIBLE MA HEW L.G LZER <br /> THROUGHQTVLIGHTING, NOSUBSTITUTIONSAGCEPTED. MANAGER/PJM: CEIIINGS.ACCE55PANEL5NOT5HOWNSHALLNOTBEMSTALLE� INGW. BO <br /> 309. �"'�� '�� " GARYMAGRENL GMAGRENI@CITVLIGHTING.WM)042353134 PJM: MIKE ]. ALL CEILING MOUNTED DEVICES SHALL BE WHITE 15. INSTALL NEW THERMOSTATS GLOSE TO DOOR OPENINGS. pO NOT INSTALL IN CEILING WITHOUT PRIOR APPROVAL STATE OF WqSHINGTON <br /> TURNEY' MTURNEY�CI�111GHTING.COM ]04-235-3135 CENTER OF WALL. ARGHITECT AND CLIENT TO APPROVE ALL LOCATIONS. <br /> e. PROVIOE BLOCKING ABOVE GEILING REQUIRE� FOR ALL CEILING MOUNTED 24. qCCESS PANELS IN GVP. BD CEILINGS TO BE FRAMELESS; COORD. WI ARGHITECT. <br /> 310. PAINTACTCEILINGTILE & GRIDPT-3. SEEMATERIALFlNISH Z. SOLUTIONTOINCORPORATELIGMTREDUCTIONCONTROLS(OCCUPANTSENSOR EpUIPMENT. PROVIDEADD�TIONALSUPPORTFORLIGHTFIXTLIRESAS 16.ALLLIGHTSTOBECONTROLLE� BYMOTIONSENSOR. PROVIDEOVERRIOE GROUP�EVICES <br /> iX'-X" INOICATESCEILINGHEIGHTABOVEFlNISHED ANDOAVLIGHTZONECONTROL). <br /> LEGEND. RECOMMENDED BV FIXTl1RE MANUFACTURER. SWITCH AT ALL CONPEftENLE ROOMS <br /> 3. FOLLOWING COMPLETION OF THE ACOUSTICHL CEILING INSTALLATION, ALL JOINTS g LOCATE ANV CONTROLS THAT NEED ACLESSING OVER ACOUSTICAL CEILMG TILE 1]. ALL LAMPS SHALL BE I�ENTICAL FROM ONE MANt1FACTUREft IN SAME 25 MI NIUM 5'AABOVE H�IGIHES�T FlNIS�HEDTCEILMG OANMPIPES, ETC. HEIGHTS, <br /> 3'I1. GWB SOFFIT PAINT PT-17. SEE MATERIAL FINISH LEGEND. ANp GRID SHALL BE STRAIGHT, TRUE TO LINE, IMTH EXPOSED SURFACES FLUSH qREA5. 00 NOT PLACE ANV ABOVE GVPSUM BOAR�CEILINGS, UNLE55 APPROVE�BV TEMPERATURE, UON. <br /> ANO LEVEL. OIRTV OR DISCOLORED SURFACES OF TILE ARE TO BE 0.EANE� OR <br /> REPLACED,AND LEFT FREE OF DEFECTS. AFTER 30 �AVS FROM SUBSTNNTIAL ARCHITECT. PROJECT STATUS <br /> COMPLETION, INSPECTTHE N/ORK ANDAOJIIST TILE NOT IN AL�GNMENTNATH 18. CENTER CEILING GRID IN ROOM OR AREA IN TYW DIRECTIONS, TYPICAL UON. <br /> 3�2. G WB SOFFIT PAI NT PT-'I . SEE MATERIA� FINISH LEGEND. OTHER CEILING TILES ANp REPLACE MISSMG OR DAMAGED UNITS. 10. PROVIDE GEILING AGCE55 RE�UIREO FOR E�UIPMENT ANO SVSTEM PQfRIII SEI <br /> MAINTENANCE. MATCH A�JACENT GEILING FINISH U.N.O. SVSTEMS AND EOUIPMENT 19. CEMER LIGHT FIXTURES/SPRINKLER HFAD/CEILING ELEMENT IN 26" PORTION OF 68" <br /> 313. 6. WITHIN A ROOM OR AREA, THE CONTRNCTOR SHALL ESTABLISH A SINGLE FLOOR RE�UIRING ACCE55 SHALL BE LOCATED AT ACCESSB�E CEILWGS. ACCESS PANELS CEILMG tILE, TVPICAL UON. JOB NUMBER <br /> ELEVHTION THAT IS TO BE 115E0 AS THE ORIGN FOR ALL CEILING HEIGHTS ABOVE NOT SHOWN ON ORANANGS SHALL NOT 8E INSTALLED IN GVPSUM BOAR�CEILINGS PO-S�AA-O'I <br /> �µ RNISHED FLOOR. NATHOUT PRIOR APPROVAL 20. LOCATE ALL LIGHT FIXTURES, SPEAKERS, LIFESAFETY DEVICES AND SIMILAR <br /> CEILING ELEMENTS. ETG, IN THE CENTER OF CEILMG TILE IN BOTH DIRECTIONS DRAWN BY CHECKED BY <br /> S. VERIFV FIEL� CONDITIONS AND LOCATIONS OF ALL MEPiFP qND STRUCTURAL 11. ALL ACCESS PANELS IN GVPSl1M BOARD GEILINGS SHALL BE FRAMELESS; AND ALIGN WITH ADJAGENT FIXTURES, DEVICES OR HEADS IN A RIIN OR ROW. IW GL , <br /> 314. ELEMENTS. CONTRACTORTOCOOROINATETHEWORKOFALLTRApESNECESSARV LOCATIONSSHALLBECOOR�INATEDWITHARCHITECT. GROUPDEVICESTO U.N.O. <br /> TOMAINTAINTHEFINISHEDCEILINGHEIGHTSINDICATED. MSTALLDUCTWORKTIGHT MINIM2ETHENUMBERANDSIZEOFACCESSPANELS. <br /> TO UNDERSIDE OF BEAMS. WITH A SMALL SPACE TOAVOI� VIBRATION. 21. REFER TO ELEVATIONS AND SECTIONS FOR MOUNTING HEIGHTS OF WALL SURFACE SHEET TITLE <br /> L INSTALLATION ANDIOR ALTERATION OF �UCTNroRK, PIPING OR OTHER EOUIPMENT 4. ALL CON�l1iTS, BOXES, DUCTS, HVAC UNITS, PIPE$ ETC., SHAIL BE MSTALLE� AS MouNreo ucnr Fixruaes. OFFICE REFLECTED <br /> THAT WILL REpUIRE FASCIAS, SOFFITS AN� OTHER TRANSITIONS IN CEILING HEIGHT HIGH AS POSSIBLE. NOT LOWER THAN e" HBOVE LINE OF HIGHEST PINISHED pp �N SEISMIC HAZARD AREAS, PROVIOE SEISMIC BRACING ATALL SUSPENDE�CEILING CEILING PUN <br /> SHAILBEREVIEWEDWITHTHEARCHRECTPRIORTOPROCEEDINGCONTRACTOR CEIIING. <br /> TO PROVIDE COMPLETE COOR�INATION DRAWINGS FOR THE ARCHITECTAND �g. THERE SHALL BE NO COMBUSTIBLE MATERIALS IN THE PLENUM SPACE. SVSTEMS. SUSPENOEO CEILMG AND BRACING SHALL MEET THE MINIMUM <br /> ENGINEER'S REVIEW REOl11ftEMENTS OF qSCA AND ASCE]40 SECTION 13.5 6. <br /> a - SHEETNUMBER <br /> � ID3 . 10 <br />