Laserfiche WebLink
.. <br /> „, <br /> . . <br /> Wing Point <br /> Associates <br /> GENERAL NOTES AND SPECIFICATIONS BUILDING CODE SUMMARY 201 IEBC: PRESCRIPTIVE COMPLIANCE, CH. 4 <br /> 2015 IBC: NEW CONSTRUCTION IN ALTERED AREAS <br /> 1. MEANS & METHODS: THE ARCHITECT IS NOT RESPONSIBLE FOR CONSTRUCTION 2015 WA ENERGY CODE: CH.5 ALTERATIONS, CHANGE OF USE <br /> MEANS AND METHODS,ACTS OR OMISSIONS OF THE CONTRACTOR OR IT'S John Bierly AIA <br /> SUBCONTRACTORS, OR FAILURE OF ANY OF THEM TO CARRY OUT WORK IN EXISTING BUILDING: PER OCCUPANCY PERMIT 206.793.9469 <br /> ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS. ANY DEFECT DISCOVERED IN TYPE V-B CONSTRUCTION FULLY SPRINKLERED wingpointassoc@gmail.com <br /> THE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE FIRST FLOOR: OCCUPANCY GROUP B 17,289 SF <br /> ARCHITECT BEFORE PROCEEDING WITH WORK. REASONABLE TIME NOT ALLOWED THE MEZZANINE: OCCUPANCY GROUP B 1,181 SF <br /> ARCHITECT TO CORRECT THE DEFECT SHALL PLACE THE BURDEN OF COST AND SECOND FLOOR: OCCUPANCY GROUP S2 16,639 SF • <br /> LIABILITY FROM SUCH DEFECT UPON THE CONTRACTOR. TOTAL (EXCL. MEZZ) 33,928 SF <br /> 2902 2. INTENT: THE ARCHITECT SHALL BE CONSULTED FOR CLARIFICATION IF SITE PROPOSED BUILDING <br /> CONDITIONS ARE ENCOUNTERED THAT ARE DIFFERENT THAN SHOWN, IF FIRST FLOOR: OCCUPANCY GROUP B 17,289 SF MEZZANINE: OCCUPANCY GROUP B 1,181 SF Rucker Ave . <br /> DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES OVER <br /> SECOND FLOOR: OCCUPANCY GROUP S2 8,793 SF <br /> THE INTENT OF THE PLANS OR NOTES. SECOND FLOOR: OCCUPANCY G P B 846 SF 0 'Z t--. <br /> Everett, <br /> WA <br /> T C . `f- 33,•'; F / <br /> 3. DIMENSIONS: INTERIOR DIMENSIONS ARE TO FACE OF DRYWALL UNLESS OTHERWISE18.1)// /,,,NOTED. EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING OR FOUNDATION WALL. ALLOWABLE AREA GROUP B (BASE) 27,000 SF J C,� <br /> ALL OPENINGS NOT LOCATED BY DIMENSIONS ON THE DRAWINGS SHALL BE 5" FROM GROUP S2 (BASE) 40,500 SF a <br /> FACE OF ADJACENT WALL SURFACE TO EDGE OF ROUGH OPENING, OR CENTERED • <br /> C/7), ��0 enovation for the <br /> BETWEEN ROOM PARTITIONS AS SHOWN. DOOR AND WINDOW DIMENSIONS SHOWN ALLOWABLE AREA INCREASE pGr 0p�� Z Skold FamilyTrust <br /> ARE NOMINAL DIMENSIONS,; VERIFY ROUGH OPENING REQUIEMENTS WITH I = [F/P-0.25]W/30 plc 1��/- <br /> MANUFACTURER. NOTE: THE EXISTING BUILDING IS NOT PLUMB AND SQUARE. ���/CO <br /> DIMENSIONS SHOWN ARE TO ESTABLISH THE MINIMUM REQUIRED OPENINGS AND <br /> F = 408 <br /> SPACES; PRIOR TO FRAMING THE CONTRACTOR SHALL VERIFY ALIGNMENT OF ALL P = 528 <br /> VERTICAL OPENINGS AND SHAFTS FOR COMPLIANCE WITH DIMENSIONAL INTENT. W = (30+30+24)/3 = 27.9 <br /> 4. STAIR AND ELEVATOR SHAFTS: VERIFY ALL SHAFT DIMENSIONS WITH EXISTING 1 I = [408/528-0.25]27.9/30 VI <br /> FRAMING CONDITIONS;ALIGN STUDS AT SHAFTWALLS WITH FACE OF EXISTING BEAMS I = [0.52] .93 . <br /> TO ALLOW DRYWALL TO RUN PAST UNINTERRUPTED. MAINTAIN SHAFT CLEAR <br /> = .48 <br /> DIMESNIONS SHOWN ON DRAWINGS. <br /> THEREFORE ALLOWABLE AREA IS: <br /> 5. INTERPRETATIONS: DO NOT SCALE THE DRAWINGS. THE ARCHITECT SHALL BE .48(9000) + 27,000 = 31,320SF FOR OCCUPANCY B • <br /> RESPONSIBLE FOR ALL INTERPRETATIONS OF DIMENSIONS AND ABBREVIATIONS. • <br /> .48(13,500) +40,500 =46,980SF FOR S2 <br /> 1ST FLR RATIO: 17,289/31,320 = .55 < 1.0 OK COPYRIGHT 2020 WING POINT ASSOCIATES LLC <br /> 6. BUILDING SYSTEMS DESIGN: ANY REQUIRED ENGINEERING DESING OR DESIGN OF THE ALL RIGHTS RESERVED <br /> i <br /> 2ND FLR RATIO: 7,846/31,320 + 8793/46,980 = .44 < 1.0 OK <br /> FOLLOWING BUILDING SYSTEMS BEYOND THE FIXTURES AS DESCRIBED IN THE OVERALL BUILDING RATIO: .55 + .44 = .99 < 3.0 OK Permit#: B2003-043 DRAWINGS WALL FOR THE RESPONSIBILITY OF THE FOLLOWING DESIGN BUILD Site Address: 2902 RUCKER AVE <br /> SUBCONTRACTORS: PLUMBING SYSTEM; ELECTRICAL SYSTEM;AND HEATING, 1ALLOWABLE BUILDING STORIES Owner: DMT RUCKER LLC <br /> VENTILATION,AND AIR CONDITIONING (HVAC) SYSTEM. FIRE PROTECTION SYSTEMS, B/S2 ALLOWABLE STORIES, PROPOSED 2 (OK) Tenant: [TenNartte] <br /> INCLUDING SPRINKLER DESIGN, SMOKE DETECTOR LOCATIONS, FIRE ALARM PULL MEZZANINE COMPLIES WITH IBC 505.2.3.3 X1 App.Date: 3/27/2020 <br /> LOCATIONS, FIRE EXTINGUISHER LOCATIONS,AND ANNUNCIATOR AND FIRE <br /> DEPARTMENT CONTROL PANEL LOCATIONS AS REQUIRED BY IBC CHAPTER 9 SHALL BE 1 ALLOWABLE BUILDING HEIGHT 1 Proposed Use: COMMERCIAL 1 <br /> THE RESPONSIBILITY OF THE FIRE PREVENTION DESIGN BUILD CONTRACTOR WHO B2/S2 ALLOWABLE 60', PROPOSED 28'10" (OK) Description: CONVERT 2ND FLOOR PARKING AREA TO <br /> SHALL PREPARE ALL SUBMITTALS REQUIRED BY IBC SECTION 107.2.2. OFFICES, <br /> • <br /> EXITI G S EG ESS PLANS 18-20 OR ITING LOAD AND MALY IS Reviewed Date:®7/�/ 7-® <br /> 7. ELECTRICAL: RECEPTACLES IN BATHROOMS, KITCHENS AND GARAGES SHALL BE G.F.I. <br /> OR G.F.I.C. PER NATIONAL ELECTRICAL CODE REQUIREMENTS. ZONING CODE SUMMARY CHAPTER 19.19 (UM ZONE) PEDESTRIAN STREETS (HEWITT & R ER <br /> Office Set Job Site Set Fire/Planning Set <br /> OFFICE - PERMITTED USE <br /> 8. VENTILATION: VENT FANS (MIN 100CFM) SHALL BE PROVIDED IN TOILET ROOMS AND PARKING - PERMITTED ACCESSORY USE <br /> KITCHENS. ENCLOSED RECREATION- PERMITTED USE <br /> 9. WEATHER AND0' SETBACKS — - <br /> AIR TIGHTNESS: INSTALL POLYISOCYANURATE FOAM TYPE INSULATION <br /> AT FLOOR AND PLATE LINES, OPENINGS IN PLATES, CORNER STUD CAVITIES AND CHAPTER 19.20,100.B3 STREET TREES @ 50'O.0 <br /> SIDEWALK TREATMENT <br /> AROUND DOOR AND WINDOW ROUGH OPENING CAVITIES. ALL EXTERIOR WALL WEATHER PROTECTION ON HEWITT <br /> OPENINGS, FLASHING, COUNTERFLASHING, ETC. SAHLL BE CONSTRUCTED IN SUCH A RECESSED ENTRIES <br /> MANNER AS TO MAKE THEM WATERPROOF. ACCESSORIES MOUNTED ON OR WITHIN <br /> WALLS SHALL BE INSTALLED AND SEALED TO PROTECT THE STRUCTURAL ELEMENTS <br /> CHAPTER 19.34.050 PARKING AREA A OF METRO EVERETT <br /> FORM MOISTURE. NO PARKING REQUIRED I.- <br /> 2 BICYCLE SPACES REQUIRED r , <br /> 10. BLOCKING: PROVIDE SOLID WOOD BLOCKING FROM 2X MATERIAL BEHIND ALL `„J <br /> INSTALLED ITEMS SUCH AS CABINETRY, WOOD TRIM, BATH ACCESSORIES, ETC. W <br /> 0 <br /> CL <br /> REVISION <br /> LABEL DATE DESCHIP-I ION <br /> 2 6/6/20 PERMIT COMMENTS <br /> DRAWING INDEX <br /> LABEL TITLE <br /> A-1 PROJECT INFORMATION PROJECT INFORMATION <br /> A-2 FLOOR PLAN SCHEDULES <br /> 0 <br /> A-3 FIRST FLOOR&SITE PLAN APPLICANT TEAM <br /> A-4 MEZZANINE PLAN <br /> A-5 SECOND FLOOR PLAN OWNER: DMT RUCKER LLC (ALIDA SKOLD) <br /> A-6 ROOF PLAN CONSTRUCTION MANAGER:'1 NORTH CREEK CAPITAL (MIKE MORGAN) <br /> A-7 NORTH & EAST ELEVATIONS ARCHITECT: WING POINT ASSOCIATES (JOHN BIERLY) <br /> A-8 WEST&SOUTH ELEVATIONS STRUCTURAL ENGINEER: SWENSEN SAY FAGET (GREG COONS)A-9 BUILDING SECTIONS <br /> A-10 EXTERIOR DETAILS <br /> A-11 FIRST FLOOR REFLECTED CEILING PLAN & LIGHTING SCHEDULE PREAPPLICATION FILE #: 19-055 R q:V, L :1 FOR t is i,,>I I <br /> A-12 MEZZANINE REFLECTED CEILING PLAN <br /> A-13 SECOND FLOOR REFLECTED CEILING PLAN PROJECT ADDRESS: 2902 RUCKER AVENUE, EVERETT, WA A-14 NORTH EXIT STAIR, ELEVATOR, &LOBBY PLANS & SECTIONS <br /> - '� - DATE._ <br /> Al- SO STAIR A AND SECTIONS—, LEGAL DESCRIPTION: EVERETT PLAT OF BLK 680 D-00 - LOTS 33THRU 38 <br /> 16 vIN�RIOR P LEVATlONS , " AILS <br /> A-17 CABINET SCHEDULE <br /> A-18 FIRST FLOOR EGRESS PLAN <br /> A-19 MEZZANINE EGRESS PLAN <br /> -Ws :0 00O THE[ISSUANOCE BEEN 6/23/20 - <br /> A-20 SECOND FLOOR EGRESS PLAN 00 0 <br /> Vit p <br /> pOgt�10 O�tKs MECHANICAL,FIRE <br /> S�p�,�ESSl�i�,M�S ELECTRICAL G <br /> � � plmR SCALE <br /> Additional Permitsire Required <br /> For This Projec T� Include: . .. <br /> Plumbing Sprinkler SHEET <br /> Mechanical Fire Alarm <br /> amI <br />