My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2701 ROCKEFELLER AVE 2020 Plans 2023-09-18
>
Address Records
>
ROCKEFELLER AVE
>
2701
>
Plans
>
2701 ROCKEFELLER AVE 2020 Plans 2023-09-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2023 7:52:15 AM
Creation date
7/8/2021 10:01:04 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2701
Permit
B2006-044
B2009-016
Year
2020
Notes
B2006-044 - CONCRETE WORK ONLY - FNDTN THRU LEVEL4 FLOOR SLAB B2009-016 - 8 STOREY MULTI-FAMILY W/ WOOD FRAME APARTMENTS - PH2
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
253
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WINDOW AND GLAZING NOTES U) 0 <br /> / 11'-1 1/4" / / 10'-10 1/4" / 3'-9" 5'-6 1/2" / 1T-10 7/8" / LLI °' N <br /> 1 . ALL CASEMENT WINDOWS IN SLEEPING AREA TO PROVIDE PROVISIONS AS NECESSARY TO SERVE AS ` a0 <br /> EMERGENCEY ESCAPE AND RESCUE OPENINGS PER IBC1030. NET CLEAR AREAS TO EXCEED MINIMUM EQ g EQ g EQ g EQ g EQ j. EQ / SZ z v, m ri <br /> CLEAR OPENING OF 5.7 SQ FEET PER IBC 1030.2. THE HEIGHT OF CLEAR OPENINGS ARE TO BE GREATER EQ q 31-8" , EQ 3'-3" C- EQ 5 EQ 3'-3 112" <br /> THAN 24 INCHES IN HEIGHT AND 20 INCHES IN WIDTH PER IBC 1030.2.1. THE BOTTOM OF THE CLEAR 14" / / \ / 4"� 5 1/2" 5 1/2"EMI <br /> 5`1/2"� N °) a' <br /> IL <br /> OPENINGS ARE 44 INCHES ABOVE FINISH FLOOR PER IBC 1030.3. NO KEYS NOR TOOLS WILL BE \--- - \ T __ _. c� N <br /> REQUIRED TO OPERATE WINDOWS PER 1030.4. • / / � <br /> / / N WF-1 > < /1 I m oN�D <br /> / \L _ <br /> 2. VINYL WINDOWS: U-VALVE = 0.26 SHGC = 0.40 • / II <br /> STOREFRONT WINDOWS: U-VALVE = 0.38 SHGC = 0.40 - • / '4' / °' N <br /> 0 4 rE0 � <br /> 3. ALL WINDOWS SHOWN FROM INTERIOR. ao / Co co 3-6" Cof 1 <br /> / \3-0H / / \ \ -/ - `l v <br /> 4. WINDOW TYPE A AND B TO MEET THE REQUIREMENTS FOR EMERGENCY ESCAPE & RESCUE OPENINGS Co <br /> (IBC 1030). SEE SHEET CS-4 FOR REQUIREMENTS & COMPLIANCE. T T/ T T T T T T T T T T T T T N <br /> FINISHED FLOG _ - \ - - _ \- - _ - \ -\ \ <br /> 5. CONTRACTOR TO VERIFY ROUGH OPENING DIMENSIONS IN FIELD BEFORE ORDERING WINDOWS. <br /> 1 2 0 0 '2 O CLARK I BARNES <br /> 6. T = TEMPERED GLASS LITE. 4\�/7 <br /> 7. IBC 2403.1: EACH PANE SHALL BEAR THE MANUFACTURER'S MARK DESIGNATING THE TYPE AND <br /> THICKNESS OF THE GLASS OR GLAZING MATERIAL. EACH PANE OF TEMPERED GLASS, EXCEPT <br /> TEMPERED SPANDREL GLASS, SHALL BE PERMANENTLY IDENTIFIED BY THE MANUFACTURER. THE <br /> IDENTIFICATION MARK SHALL BE ACID ETCHED, SAND BLASTED, CERAMIC FIRED, LASER ETCHED, <br /> EMBOSSED OR OF A TYPE THAT, ONCE APPLIED, CANNOT BE REMOVED WITHOUT BEING DESTROYED. <br /> TEMPERED SPANDREL GLASS SHALL BE PROVIDED WITH A REMOVABLE PAPER MARKING BY THE / 6'-0" / <br /> MANUFACTURER. /21-3" 1 31-9" , / 13'-33/4" / 5'-7" / <br /> 5' 7" <br /> 8. IBC 2406.3: EACH PANE OF SAFETY GLAZING INSTALLED IN HAZARDOUS LOCATIONS SHALL BE 3' 9" EQ EQ EQ 3'-9" 10" 10'i 3' 9" <br /> IDENTIFIED BY A MANUFACTURER'S DESIGNATION SPECIFYING WHO APPLIED THE DESIGNATION, THE i� - / ( X / / <br /> MANUFACTURER OR INSTALLER AND THE SAFETY GLAZING STANDARD WITH WHICH IT COMPLIES, AS <br /> WELL AS THE INFORMATION SPECIFIED IN SECTION 2403.1. THE DESIGNATION SHALL BE ACID ETCHED, � \ \ / \ / Ct <br /> ' 1 ' <br /> SAND BLASTED, CERAMIC FIRED, LASER ETCHED, EMBOSSED OR OF A TYPE THAT ONCE APPLIED, • / / \ W <br /> CANNOT BE REMOVED WITHOUT BEING DESTROYED. \ / / \ <br /> • <br /> \ / / � � J W <br /> 9. IBC 2403.4: WHERE INTERIOR GLAZING IS INSTALLED ADJACENT TO A WALKING SURFACE, THE 41 . \ b o / / b / - _ <br /> DIFFERENTIAL DEFLECTION OF TWO ADJACENT UNSUPPORTED EDGES SHALL NOT BE GREATER THAN ) ' <br /> THE THICKNESS OF THE PANELS WHEN A FORCE OF 50 POUNDS PER LINEAR FOOT IS APPLIED n 3,$, Co \31-6" • <br /> \3,-6,I °D 3' 6"/ w Q O <br /> HORIZONTALLY TO ONE PANEL AT ANY POINT UP TO 42 INCHES ABOVE THE WALKING SURFACE. / / / / r / \ / I / U. W O <br /> NOT USED / J <br /> / a) <br /> 10.ALL WINDOWS AND DOORS TO MEET REQUIREMENTS OF THE 2016 WASHINGTON STATE ENERGY CODE, T t T \ T T T T rt\ T T W J Q <br /> SEE SHEET CS-6 FOR ALL ENERGY CODE REQUIREMENTS. if FINISHED FLOOR <br /> \ - - - \ • <br /> - - - - - \ - - - - - - - MIN. IHRRATED LL <br /> 11 .WINDOW ACCESSIBILITY IN TYPE 'A" UNITS (ICC/ANSI A117.1-2003 SECTION 1003.13): 0 0 MIN. 1 HR RATED r , Y <br /> IN TYPE 'A' UNITS, WHERE OPERABLE WINDOWS ARE PROVIDED, AT LEAST ONE WINDOW IN EACH v 0 I-SLEEPING, LIVING, OR DINING SPACE SHALL HAVE OPERABLE PARTS COMPLYING WITH SECTION 1003.9. (26W <br /> EACH REQUIRED OPERABLE WINDOW SHALL HAVE OPERABLE PARTS COMPLYING WITH SECTION 1003.9. O <br /> OPERABLE WINDOWS SHALL COMPLY WITH SECTION 309 AS FOLLOWS: O W <br /> 1. A 30" X 48" CLEAR FLOOR SPACE SHALL BE PROVIDED PER SECTION 305. SEE SHEET CS-8. <br /> 2. OPERABLE PARTS MUST BE IN THE REACH RANGE PER SECTION 308. SEE DIAGRAM ON SHEET CS-9. <br /> 3. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, r <br /> PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL O <br /> BE 5.0 POUNDS MAX. 13'-1 7/8" <br /> 4. OPERABLE PARTS AFTER OPERATION TO RELEASE THE CONTROL DEVICE ALLOWING THE WINDOW 4„y / ^ ' <br /> TO FULLY OPEN, SHALL NOT REDUCE THE MINIMUM NET CLEAR OPENING AREA OF THE WINDOW UNIT / EQ EQ I EQ EQ / ` V <br /> TO LESS THAN THE AREA REQUIRED BY SECTION 1029.2 <br /> 12. ALL WINDOWS WHOSE OPERABLE PARTS FALL BELOW 36" ABOVE FINISHED FLOOR SURFACE SHALL BE <br /> EQUIPPED WITH HARDWARE RESTRICTING THE OPENING TO A DIMENSION OF 4" AT ITS WIDEST POINT, <br /> IN COMPLIANCE WITH IBC 1013.8 EXCEPTION 2. <br /> aD <br /> 13. PER ANSI A117.1 - 2009, CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" HIGH MAX SHALL BE BEVELED WITH A n <br /> SLOPE NOT STEEPER THAN 1:2 9 <br /> Co <br /> 14. TRICKLE VENTS TO BE LOCATED AT THE BOTTOM OF WINDOWS AND SIDES, 3' AWAY FROM ALL UNIT <br /> EXHAUST OPENINGS. <br /> FINISHED FLOOR -\ T T T T - <br /> SAFETY GLAZING S <br /> IDENTIFICATION OF SAFETY GLAZING - IBC 2403.1 <br /> EACH PANE OF SAFETY GLAZING INSTALLED IN HAZARDOUS LOCATIONS SHALL BE IDENTIFIED BY A <br /> MANUFACTURER'S DESIGNATION SPECIFYING WHO APPLIED THE DESIGNATION, THE MANUFACTURER OR <br /> INSTALLER AND THE SAFETY GLAZING STANDARD WITH WHICH IT COMPLIES. THE DESIGNATION SHALL BE <br /> ACID ETCHED, SAND BLASTED, CERAMIC FIRED, LASER ETCHED, EMBOSSED OR OF A TYPE THAT ONCE <br /> APPLIED, CANNOT BE REMOVED WITHOUT BEING DESTROYED. <br /> HAZARDOUS LOCATIONS - IBC 2406.4: <br /> THE FOLLOWING SHALL BE CONSIDERED HAZARDOUS LOCATIONS REQUIRING SAFETY GLAZING <br /> MATERIALS: <br /> GLAZING IN SWINGING DOORS <br /> GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES <br /> GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST <br /> EXPOSED EDGE OF THE GLAZING IS WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A )6611 REGISTERED <br /> CLOSED POSITION & WHERE THE BOTTOM EDGE OF THE GLAZING IS < 60" ABOVE THE WALKING ARCHITECT <br /> SURFACE. <br /> GLAZING IN A FIXED OR OPERABLE PANEL THAT MEETS THE FOLLOWING CONDITIONS: <br /> A. EXPOSED AREA OF PANE IS > 9 SF W SCOTT CIARK <br /> B. EXPOSED BOTTOM EDGE IS < 18" ABOVE THE FLOOR STATE OF WASHINGTON <br /> C. EXPOSED TOP EDGE IS > 36" ABOVE THE FLOOR <br /> D. ONE OR MORE WALKING SURFACES WITHIN 36" HORIZONTALLY OF THE PLANE OF THE GLAZING. <br /> • GLAZING ADJACENT TO STAIRWAYS, LANDINGS & RAMPS WITHIN 36" HORIZONTALLY OF A WALKING <br /> SURFACE; WHEN THE EXPOSED SURFACE OF GLASS IS LESS THAN 60" ABOVE THE PLANE OF THE DATE: 01/25/21 <br /> ADJACENT WALKING SURFACE. JOB NO. 19-48 <br /> PERMIT NO.B2006-044 <br /> B2009-016 <br /> REVISIONS:^^ <br /> A <br /> DATE DESCRIPTION <br /> 1 01/19/21 PERMIT REV 1 <br /> 2 02/19/21 PERMIT REV 2 <br /> 9 04/08/21 IFC ADD 01 <br /> ISSUE: <br /> SHORING/EX 05/08/20 <br /> PHASE I 06/22/20 <br /> BID PROG SET 07/13/20 <br /> PHASE II . 08/31/20 <br /> GMP 09/30/20 <br /> PERMIT REV 1 01/19/21 <br /> IFC SET 01/25/21 <br /> PERMIT REV 2 02/19/21 <br /> IFC SET 02/19/21 <br /> PERMIT REV 3 05/26/21 <br /> INTERIOR <br /> STOREFRONT <br /> TYPES <br /> CITY OF EVERETT <br /> VIEWED FOR PERMIT <br /> SHEET NO' <br /> A8 . 06 <br />
The URL can be used to link to this page
Your browser does not support the video tag.