<br /> UNIT GENERAL NOTES: ^
<br /> co
<br /> / EQ I EQ ?, 2 1/2/ 1. DIMENSIONS FOR ALL ENLARGED UNIT PLAN ARE FROM °D/ r�
<br /> 2,_0„/ GRID LINE OR FACE OF STUD, U.N.O. :icor
<br /> � �
<br /> •
<br /> 2. REFERENCE STRUCTURAL DRAWINGS FOR BEARING SZ
<br /> iAo
<br /> (1 AND SHEAR WALLS LOCATIONS WITHIN UNITS. N\ STRUCTURAL WALLS LOCATED INSIDE UNITS ARE TOI__ °' '"N © BE 1 HR RATED WALLS PER TESTED ASSEMBLY. NSDK BL-2 > REFERENCE WALL ASSEMBLY SHEETS. a0\ C�® VW iONN �iO B1 OPEN 1 BED 2'-1" EQ EQ _ 3. FOR UNIT KITCHENS SEE ENLARGED UNIT KITCHEN m/ -1' �,�„/ 498 SF PLANS & ELEVATIONS ON SHEETS ON A6-20 - A6.23. �y'� oN
<br /> ` � - - - - Ei 1 I I rcoF-
<br /> 9 _ _ 1'-0" EQ EQ 1'-8 1/4" EQ EQ 2'-0" T -51n" 4. FOR UNIT BATHROOMS SEE ENLARGED UNIT U
<br /> l a �' I �r_ - . 8,_a„ . BATHROOM PLANS & ELEVATIONS ON A6.25 - A6.28.
<br /> . \ / I / 4'-6 1/2" j ,I
<br /> M v II 1
<br /> to 5. SEE SHEETS CS17 FOR TYPICAL MOUNTING HEIGHTS,
<br /> BL-2 to DISTANCES TO COMPLY WITH STANDARD
<br /> ® M
<br /> SD 1 I r I ( ` 9 �I _ \ EQ EQ EQ EQ ACCESSIBILITY DETAILS. ® s
<br /> ff .. . .
<br /> 9.23 I Co w o f I \ \� : 6. COAT AND WARDROBE REQUIREMENTS FOR TYPE 'A'
<br /> BL2 r,\ : \ BL-2 � / I �\ I :\ SD c_q I _ 0- -4 - - - - UNITS: FORA SIDE REACH, ENSURE A PORTION AT 46"
<br /> I ~__D SD -' C sD D ` \I 4 I , I- MAX. AFF FORA 24 MAX. REACH, OR 48 MAX. AFF FOR
<br /> CO A! .1 STUDIO I Co D' A 10" MAX REACH. FORA FULL FRONT APPROACH
<br /> • .S l 0 \ 3' W 468 SF I '-3" G W W q'-6') I 1 k' o (WALK IN CLOSETS OR PASSAGE WIDTH DOOR),
<br /> / --: I r-51n"46,
<br /> / I I ENSURE 48" AFF.
<br /> 0 - - - - __ - - O I
<br /> Cr O r-s1a•, ' '- � ,I, 7 SEC 004D11C30DE INFORMATION PER 2009 FOROPTONA & BBATHROOMCA117.1
<br /> 8'-33r4 W 8'_a, •
<br /> / � 1_0„ EQ EQ ir / 8'-33/4• a O' 8,_4„ r REQUIREMENTS, REFER TO CS SHEET CS17-CS18.
<br /> A4_STUDIO A5 STUDIO •�
<br /> • 8. TYPICAL CEILING HEIGHTS WITHIN LIVING AND
<br /> 376 SF 427 SF C'7 © ,. r �3 3 W _ CFM i1
<br /> g,23 o CIRCULATION AREAS OF A DWELLING UNIT SHALL BECt
<br /> I \ \ - \ \ j .. m 8' 4" AFF, WITH THE EXCEPTION OF 10' 6" AFF AT LEVEL 1
<br /> . • 8'- 3 3/4" \ 0 \ ® r-T �' �" �' AND 9'-3" AFF AT LEVEL 8. CEILING HEIGHT ELEVATIONS w
<br /> \ -I_ Q I -- r r �„ ¶ :.I e,_a„ WILL APPLY TO UNDERSIDE OF FLOOR ASSEMBLY. J
<br /> \ \ 9. FOR UNITS ON LEVEL 1, DROPPED SOFFITS SHALL BE W
<br /> 1 a'-a" \ m - - 'T-71 \ r' .. LOCATED AT 8'-8" AFF, WITH A LOWER SOFFIT AT T-7"
<br /> I I 47' 50F �j7 OCCURING AT KITCHEN CABINETS. FOR UNITS ON LEVEL w Q O
<br /> FL ��`9FM I - w So- FM LOu ('1 T I " LL w N
<br /> - O _ w I 8, DROPPED SOFFIT SHALL BE LOCATED AT 8'-6 AFF,
<br /> - • - 2 - - - .
<br /> 1' 6" w \ ► CFM WITH A LOWER SOFFIT AT 7'-7" OCCURING AT KITCHEN W W 0)
<br /> D-1 \ - - Q'� D-1 _ - X D_1 per., _. _ \ .. . 50 Lam : - \ iQ CABINETS. -J Q
<br /> O co �c `i Typ 0 I"1 - -� TYP sr- - - = O ,CFM r r C'J . rn Ill
<br /> I • 1' 6'/ - t w . 10. LIGHTING TO BE CENTERED IN ROOMS, U.N.O. If
<br /> TYP 50 •
<br /> \ - - - 50 {\ - • CFM W
<br /> a In
<br /> -' - w w 11 ALL GYP CEILINGS TO BE PT- U.N.O. 0
<br /> I CFM I - _ Cr('� - I L -D-1 Y I-
<br /> ki W h W -�_- r . \ TYP 1, U. -
<br /> 1
<br /> i.
<br /> 0 1 IL l _ II . 2 O W
<br /> . � L1 r C7 -1 . I 0, .' w .
<br /> \ _ I . _ \ - - -J T Ic4K -I . w 1 I _� „ `� _ I -II-4 I 12. REFER TO BUILDING SECTIONS & ASSEMBLIES FOR O ° CK
<br /> • I
<br /> I I ( CEILING CONDITIONS II W
<br /> 1 EQ EQ I,2'-0"j,j, EQ I. EQ 2'-6" EQ EQ EQEQEQEQUNIT NAMING LEGEND: O W
<br /> EQ / EQ // EQ EQ / / / / XXX / / 1 �- - je / A STUDIOS N
<br /> B OPEN-1 BEDROOM
<br /> A4RCP 4 A5 RCP $ A5. 1RCP 7 B1RCP D 2BEDROOM O(2)
<br /> 6. SCALE: 1/4" = 1'-0" A6.00J SCALE: 1/4" = 1'-0" A6.0 SCALE: 1/4" = 1'-0" \6.0 SCALE: 1/4" = 1-0" RCP LEGEND ` I
<br /> UNIT RCP ELEVATION (FF TO GWB
<br /> CEILING) :
<br /> SEE BUILDING SECTIONS FOR
<br /> INDICATED A.F.F. HT.
<br /> n CIRO
<br /> 0
<br /> 1-1
<br /> F=
<br /> RCP GWB SOFFIT
<br /> B1 EXT CONDITION 2: ROOMS 219, 220 SEE UNIT RCP FOR INDICATED A.F.F. HT.
<br /> B q1
<br /> B4 -
<br /> UNIT FINISHES PER LEVEL Al FOS 0 RECESSED CAN LIGHT
<br /> LEVEL 4 LEVEL 5-8 -
<br /> CONC-1 UNIT FINISHES PER LEVEL
<br /> ± PENDANT LIGHT FIXTURE / J BOX
<br /> CONC-1 LVT-1
<br /> VVB-1 we-1 LEVEL 4 LEVEL 5-8 WB-1
<br /> _ PT-1 VANITY WALL SCONCE
<br /> PT-1 PT-1 �}p
<br /> _ � CONGA LVT-1 1
<br /> A5 EXT CONDITION 2: ROOM 324 WB-1 WB-1 B1_OPEN 1 BED
<br /> 0 0 .--. PT-1 PT-1 498 SF 50 CFM
<br /> ' y1 (;) RANGE EXHAUST
<br /> FOS
<br /> n (224) Al 0 Al 50 CFM
<br /> \ I
<br /> I0 BATHROOM / LAUNDRY EXHAUST
<br /> \ h I I= - - ¢
<br /> •
<br /> FOS ' 4) o a
<br /> a FOS • o \ - • SMOKE DETECTOR & CARBON
<br /> CSC-1 a a I f a 1 I SD CO MONOXIDE DETECTOR l REGISTERED
<br /> PT-1 .. l T� 7
<br /> 1
<br /> 3 A5.1 STUDIO I I �. 5.f,(' Gk" `-
<br /> li SMOKE DETECTOR ONLY
<br /> I ( SD w. SCOTT Cwu
<br /> 467 SF V STATE OF WASHINGTON
<br /> A5 STUDIO P1 '_ A6.2�2 Ii I j I o
<br /> A4 STUDIO �� 427 SF •
<br /> co 9 I 1
<br /> A6.20 3 �6.2., '. : a o I OIO
<br /> 376 SF Oo, CEILING MOUNTED FAN WITH LIGHT DATE: 01/25/21
<br /> IIN
<br /> _ \ T - / 3'-11 1/2" / 5' 2 1/2" / a - I ° (} i Ft a C\ JOB NO. 19 48
<br /> i , \ _� a ® a `� ' 1 C-14> \ 13� I I 1 v PERMIT NO.62006-044
<br /> if-CI ••• ii
<br /> lai•
<br /> N o l -a I 1- B2009-016
<br /> I I P29 0 2 - - - - N 1 J I \ - - 10 - - N 1 e i P29 �_ a 51 a P4 I i REVISIONS:
<br /> - `\\ I I KEY NOTES
<br /> ' - ° DATE DESCRIPTION
<br /> P29 I I I X / �\� (NI\ C O O I I �� tc, \ �/� I I 1 Ol/19/21 PERMIT REV 1 '
<br /> O I j X_ [ I �• 1 - - P29 �1J I in M �/ 1 O 30" x 48" CLEAR FLOOR SPACE 9 04/08/21 IFC ADD 01
<br /> ♦ I m OI O I 2'-0„ I \ i 1 i fs,,.j„)I I \ \ r S. _
<br /> 0 PONY WALL TO UNDER SIDE OF COUNTER
<br /> I I X-2) 1 0> r I a /- 1 - 1 a l
<br /> 1 f : ,FOSS I i -LH I I -I I Lt., zt
<br /> NI
<br /> If FOS FOS ® _ I FOS FOS �,. ( l FOS ��S FOS ISSUE:
<br /> \ _ \ i ,�,� SHORING/EX 05/08/20\ \ FOS 9 7 1/4" FOSCI) \ \ N N \ \ N ® o u_ (� 2,-7 4;v� )` \ PHASE I 06/22/20
<br /> ' v. wii LL - / ,' BID PROG SET 07/13l20
<br /> T-2 1/2" T 1 1/2" SIM „ _ „ O 6' 11 3/4" 1'-8 3/4" 1/ w 16 LL 18" MINI
<br /> M
<br /> 9'-6� 8 11 1/2 � M v A6.25 PHASE II 08/31l20
<br /> O
<br /> 18" MI
<br /> / // , / /� / 12'-2 1/4" Jr' 7'-10 1/2" / 8' 9" 6' 31/2" / GMP 09/30/20
<br /> 14'-4" / 18-51/2' / I 20'-0 3/4" 15'-0 1 ' / PERMIT REV 1 01/19/21
<br /> / / IFC SET 01/25/21
<br /> PERMIT REV 2 02/19/21
<br /> A4 STUDIO A6.0 3 A5 STUDIO s A5. 1 _STUDIO 6 B1OPEN 1B IFC SET 025/19/21
<br /> PERMIT REV 3 0 / 6/21
<br /> A6.9 SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" A6.0 SCALE: 1/4" = 1'-0" A6.0 SCALE: 1/4" = 1'-0"
<br /> - -A4STUDIO A5 STUDIO A5.1 STUDIO B1_OPENIB ENLARGED
<br /> 413 224 424 219 UNIT PLANS
<br /> CITY OF EVERETT
<br /> 414 324 524 REVIEWED FOR PERMIT
<br /> 513 624 319
<br /> 514 724 320
<br /> 613 823
<br /> 614 SHEET NO:
<br /> 714 •
<br /> 713
<br /> 813 812 A6 . 03