Laserfiche WebLink
UNIT GENERAL NOTES: _ <br /> VCO <br /> 1. DIMENSIONS FOR ALL ENLARGED UNIT PLAN ARE FROM 00 <br /> r` <br /> GRID LINE OR FACE OF STUD, U.N.O. W T, °' <br /> 2. REFERENCE STRUCTURAL DRAWINGS FOR BEARING Y _ rn co <br /> AND SHEAR WALLS LOCATIONS WITHIN UNITS. �_ o cN' <br /> STRUCTURAL WALLS LOCATED INSIDE UNITS ARE TO NN °7 ''" <br /> IL m t o <br /> BE 1 HR RATED WALLS PER TESTED ASSEMBLY. O N N <br /> 1'-10 1/4" EQ EQ EQ EQ / / EQ EQ // EQ EQ 1'-10 1/4" REFERENCE WALL ASSEMBLY SHEETS. /r <br /> EQ EQ EQ EQ 1'-101/4" t i 111.1rri - \L <br /> " SEE A1.37 LEVEL 6 RCP 3. FOR UNIT KITCHENS SEE ENLARGED UNIT KITCHEN Im <br /> I I FOR ALTERNATIVE PLANS & ELEVATIONS ON SHEETS ON A6.20 - A6.23. I o m N <br /> IFI SIn <br /> OFFIT IN UNITS 610 c <br /> 4. FOR <br /> HROOMAPLANS &BATHR SEEOOMSLARGED ELEVATIONS ON A6.25T A6.28. <br /> BL-2 <br /> �Mi ___IL�ii1 \� \ 5. SEE SHEETS CS17 FOR TYPICAL MOUNTING HEIGHTS, <br /> �� / I SD DISTANCES TO COMPLY WITH STANDARD <br /> c �� CO�'I is . ,CBL2- :> < BL'2 BL2 I �] 0 \ ACCESSIBILITY DETAILS. <br /> 0 _ M VCLARK I BARNES <br /> I I " w w r ®CDO .- ;I� I 6. COAT AND WARDROBE REQUIREMENTS FOR TYPE 'A' <br /> LO <br /> '� - I UNITS: FOR A SIDE REACH, ENSURE A PORTION AT 46" <br /> 3' 3Ic MAX. AFF FORA 24" MAX. REACH, OR 48" MAX. AFF FOR <br /> - - O O - - - -- - \ - - - - - - O / ,0 - - - - O 3 A 10" MAX REACH. FOR A FULL FRONT APPROACH <br /> N 2'-0" II 2'-0" (WALK IN CLOSETS OR PASSAGE WIDTH DOOR), <br /> 7'-5 1t7 C'J a • <br /> 8'_8, / ,, N XZ'-0"/ g'- 3 3/4" .in9.23 ENSURE 48" AFF. <br /> ® C2 1-BED W W ' ®� 8'-33/4" � ® yr� lb' <br /> 8' 4" b SD - 9'_g„ SD 9' S" 'n o sq 7. FOR ADD'L CODE INFORMATION PER 2009 ICC A117.1 <br /> k <br /> 574 SF SEC1004.11.3 FOR OPTION A & B BATHROOM <br /> NI <br /> C2.1_1-BED <br /> '�M �� \ \� I .1 \ $OS SF REQUIREMENTS, REFER TO CS SHEET CS17-CS18. <br /> EQ EQ EQ EQ g•_a" EQ EQ EQ EQ CJ O EQ , EQ EQ y EQ <br /> W �I' KITCHEN / �' // .}' / w W // . KITCHEN I 8. TYPICAL CEILING HEIGHTS WITHIN LIVING AND <br /> i ISLAND _ - ISLAND T_5 1/2" <br /> �- _ -® KITCHEN �� O- _ _ - _ - - -0- - - O CIRCULATION AREAS OF A DWELLING UNIT SHALL BE <br /> a'-a^ ISLAND - BELOW 9'-8" w 8'-33/4" BELOW �L�---. 8'-4" AFF, WITH THE EXCEPTION OF 10'-6" AFF AT LEVEL 1 <br /> w .' i <br /> -BELOW A9.23 �9.2� W W Y <br /> 7' -7" r 1 ' •. \ \ I- I- - -I AND 9'-3" AFF AT LEVEL 8. CEILING HEIGHT ELEVATIONS w <br /> �M O\ r I { . C7\ \ 1 C7 7 4- WILL APPLY TO UNDERSIDE OF FLOOR ASSEMBLY. <br /> L EQ EQ EQ EQ EQ I �7, <br /> /, "� I I 0 L \ \ - o I :: - I- "'\ • , a v �' / 0 _ L \ W • <br /> w1 6X I I . .,.:0. <br /> 71T w ' 6 W I I 9. FOR UNITS ON LEVEL 1, DROPPED SOFFITS SHALL BE <br /> / \ I <br /> I 1 w te �` LOCATED AT 8-8" AFF WITH A LOWER SOFFIT AT 7-7 <br /> - C. .. . 50 I I ° JJ ®, C ® - ,� - - , 7 5D �i L 3 <br /> CFM® CFM iq I < <br /> CFM co I I min I I _ OCCURING AT KITCHEN CABINETS. FOR UNITS ON LEVEL w CK N <br /> O L-1 C7 I I w w L 1 - \ .. 8, DROPPED SOFFIT SHALL BE LOCATED AT 8'-6" AFF, <br /> w \ I < I I _ = I I : - I \ • L-t 7 I I WITH A LOWER SOFFIT AT 7 7 OCCURING AT KITCHEN 2 <br /> 8' 8 T <br /> I I f1 - d W W <br /> \ L - - J I . �50 s _ I L _I _ J - \ \ I. W\ L _+ _ J I LI CABINETS. w J Q <br /> I I'EQ I EQ� - s . -, <br /> O so �`_ �I,EQ�,EQ,t I r� ®� •M �f so j Si <br /> O 50 - i �r> W <br /> LU <br /> (�l10. LIGHTING TO BE CENTERED IN ROOMS, U.N.O. LL <br /> W CFM`- (o D-1 D-1 CFM `+' W GFM� D-1 I �' <br /> �j _ •" • <br /> \ - ~_ (I� T,pc. • <br /> \ \ \ _ �-`' TMp b - \ 11. ALL GYP CEILINGS TO BE PT-1, U.N.O. U W <br /> C5 T 71j • -r . r - - I • : 4? c� • .I*. .'. - --, W 7,L 7„ - T M 12. REFER TO BUILDING SECTIONS & ASSEMBLIES FOR 0 <br /> i Ir- -.I� -1� M M _ .Jr -r.-�•- -.-�I I g� -6�� -6 W I rH - - -T <br /> - CEILING CONDITIONS W <br /> �n�� I I % _I � J 1 I ( UNIT NAMING LEGEND: <br /> I I II A STUDIOS N <br /> EQ EQ 12'-6" 3'-0" r 3'-0" I. 2'-6" //EQ I'EQ/ <br /> B_ OPEN-1 BEDROOM <br /> �I .} /EQ/EQ2/ 2' 6" / / 3'-0" / C 1 BEDROOM SO <br /> C2 RCP CONDITION 2: ROOM 103 D 2 BEDROOM <br /> C2_RCP r6� C2. 1RCPRCP LEGEND N <br /> CD <br /> SCALE: 1/4" = 1'-0" A�'9, SCALE: 1/4" = 1'-0" <br /> UNIT RCP ELEVATION (FF TO GWB . <br /> CEILING) : <br /> SEE BUILDING SECTIONS FOR <br /> A4 <br /> 0 Q INDICATED A.F.F. HT. <br /> - P I <br /> 66 0 0RCP GWB SOFFIT <br /> 1 - I S7 S6 r , q I I I r p 1 I _ _I SEE UNIT RCP FOR INDICATED A.F.F. HT. <br /> BEDROOM A LIVING LIVING I BEDROOM rij BEDROOM LIVING ROOM <br /> C2 EXT CONDITION 2: ROOM 310 C2 EXT CONDITION 3: ROOM 103 4 ® RECESSED CAN LIGHT <br /> C2.1 EXT CONDITION 2: ROOMS 406, 506, 606, 706, 710, 806 <br /> 65 A4 - PENDANT LIGHT FIXTURE / J BOX <br /> n Al B4 Al n Al O Al 0 1 1 � \ B4 1 L VANITY WALL SCONCE <br /> FOS - - \ 50 CFM LIVING BEDROOM FOS 0 RANGE EXHAUST <br /> C2 EXT CONDITION 4: ROOM 206 P21 <br /> _ P4 UNIT FINISHES PER LEVEL 1 0 <br /> • <br /> LEVEL 4 CONC-1 LEVEL 5-8 <br /> LVT-1 50 CFM <br /> 0 BATHROOM / LAUNDRY EXHAUST <br /> CONC-1 n ^ WB-1 - <br /> WB-1 • <br /> WB1 <br /> B4 <br /> d _ PT-1 PT-1 PT-1 0 SMOKE DETECTOR & CARBON <br /> C2 1-BED I 'H' 1� iI t C2.1 1-BED SD MONOXIDE DETECTOR �71 <br /> X-4 574 SF fI II 6DB SF CO REGISTERED <br /> LIVING BEDROOM Z ARCHITECT <br /> \ -12 I 1 12 a - <br /> e I A6.20 SIM C2 EXT CONDITION 5: ROOM 306 N X-4 "� �'``�' <br /> SDSMOKE DETECTOR ONLY <br /> W. SCOTf CL RK <br /> v 7 1 P5 z - CED I Z Afi 21 STATE OF WASHINGTON <br /> • <br /> fI1 <br /> sir - a - - - - 4, Q `�fl I P23 T SIM N OD <br /> r\ , r i 1 s I o_ 4� Q ^� o CEILING MOUNTED FAN WITH LIGHT DATE: 01-/25/21 <br /> -48 <br /> -I /-Th 1 -6 X-2 F - © ' I �� r -I N D PERMI JOB OT NO.B20069044 <br /> XX P4 +� j \ CX-2) 1 L J B2009-016 <br /> 19 I (3�1'-8 1/8 F - H P5 I-I " N PTA- 1 2 I �l I REVISIONS: <br /> c____)-- <br /> 1\ _ _ -- �n KEY NOTES <br /> r DATE DESCRIPTION <br /> 2'-10" a \10 1'-1" I m ` J - P23 ♦ 1 Ol/19/21 PERMIT REV 1 • <br /> SIM , ' 1 O - 1 1 r O 30" x 48" CLEAR FLOOR SPACE 9 04/08/21 IFC ADD 01 <br /> I \ I 1 ' I- O � <br /> - -I a X,10 I - - - I - Ni ,cc, _, \ ' 0 O I 1 © PONY WALL TO UNDER SIDE OF COUNTER <br /> / I r _ ; is' 1 I I .1 �`\FOS I 1 _ _ i _ _-1AFOS 4) )0 ,`1 I _ <br /> ® \ FOS // [ - <br /> 2 O 0 3/4//' T9 3/ " OI , 0 n-- I` 7 FO \ .j ISSUE: <br /> 18 MIK/ A O 0 10" 2'-01/i 7'-23/4" O T SHORING/EX 05/08/20 <br /> 6'-0" 31-6" 13'-5" LL LL / > 18" MI 2, PHASE I 06/22/20 ' <br /> / / / - / BID PROG SET07/13/20 <br /> � 22-11 / / 3'-9 1/4" , 13' 3 1/2" PHASE II 08/31/20 <br /> 6'-1 1/2" 17'-0 3/4" GMP 09/30/20 <br /> / A <br /> PERMIT REV 1 01/19/21 . <br /> IFC SET 01/25/21 <br /> PERMIT REV 2 02/19/21 <br /> C2 1 -BED 3 C2. 1 1 -BED IFC SET 02/19/21 • <br /> A6.07 SCALE: 1/4" = 1'-0" A6.07 _ <br /> �� SCALE: 1/4" - 1'-0' PERMIT REV 3 05/26/21 <br /> • <br /> C2_1 BED C2.1_1 BED <br /> ENLARGED <br /> 103 <br /> 406 UNIT PLANS <br /> 206 410 <br /> 210 506 <br /> 306 5 CITY OF EVERETT <br /> 310 606 REVIEWED FOR PERMIT <br /> 610 <br /> 706 SHEET NO: <br /> 710 • <br /> 806 <br /> A6 . 07 <br />