Laserfiche WebLink
UNIT GENERAL NOTES: I <br /> v ) � <br /> 1. DIMENSIONS FOR ALL ENLARGED UNIT PLAN ARE FROM <br /> GRID LINE OR FACE OF STUD, U.N.O. W v °' m <br /> 2. REFERENCE STRUCTURAL DRAWINGS FOR BEARING Y z u> °' o <br /> AND SHEAR WALLS LOCATIONS WITHIN UNITS. -0 o CN! <br /> STRUCTURAL WALLS LOCATED INSIDE UNITS ARE TO 12 E°''o �a'C <br /> E ° <br /> BE 1 HR RATED WALLS PER TESTED ASSEMBLY. <br /> REFERENCE WALL ASSEMBLY SHEETS. Oro °O <br /> 3" EQ EQ yyy2'-1" 2'-0" 4'-6" 4'-8" < a��i m <br /> EQ EQ 2'-2" 1'-10" A9.� EQ EQ /'I / '� / / 3. FOR UNIT KITCHENS SEE ENLARGED UNIT KITCHEN - ~ <br /> / // / / / / 1 4 PLANS & ELEVATIONS ON SHEETS ON A6.20 -A6.23. I M o w N <br /> ' J /Hilt , , , I e \N F 4. FOR UNIT BATHROOMS SEE ENLARGED UNIT U <br /> I r r <br /> \ 1 �, He' ; \ ,� / �J $1 \ BATHROOM PLANS & ELEVATIONS ON A6.25 A628. <br /> BL • <br /> 2 I -_ - $G HH I BL-2 > 4; L- _ 1 <br /> I , BL-2 , BL-2 > <br /> I I i�IC I Z � . a a I 3 { \ < BL-2 a 5. SEE SHEETS CS17 FOR TYPICAL MOUNTING HEIGHTS, <br /> d I I O 9.23 DISTANCES TO COMPLY WITH STANDARD <br /> w � I Q w w I I �� ACCESSIBILITY DETAILS. <br /> FI I I � 0 CLARK I BARNES <br /> sc - - - O FM 1 ® \ 6. COAT AND WARDROBE REQUIREMENTS FOR TYPE 'A' <br /> - - <br /> _ •pFM I - - - - I _ UNITS: FORA SIDE REACH, ENSURE A PORTION AT 46" <br /> • 8, I O I MAX. AFF FOR A 24" MAX. REACH, OR 48" MAX. AFF FOR <br /> w _ A 10" MAX REACH. FOR A FULL FRONT APPROACH <br /> w s -6^ I 1 18' 4' El (WALK IN CLOSETS OR PASSAGE WIDTH DOOR), <br /> - _I D2_2-BED o EQ 1, EQ - ENSURE 48" AFF. <br /> 1 889 SF 4 co \ T �X / _ . 1 D2 2 BED TYPE AIT EQ -I EQ 1 7. FOR ADD L CODE INFORMATION PER 2009 ICC A117.1 <br /> i I �' / I �6' a" 17,_'� ® sD ��' �' 877 SF SEC1004.11.3 FOR OPTION A & B BATHROOM <br /> sc ® _..�' I 8'-4" - _ REQUIREMENTS, REFER TO CS SHEET CS17 CS18. <br /> 9 8D b .9'_6„ \ I _ — J \ 1 C? - <br /> ® _ _ _ _ _ _ _ 777 8. TYPICAL CEILING HEIGHTS WITHIN LIVING AND <br /> \ _TN r - \ I EQ / EQ /W CIRCULATION AREAS OF A DWELLING UNIT SHALL BE <br /> e 6 / EQ EQ /d I a C) . - \ a 81-4" AFF, WITH THE EXCEPTION OF 10'-6" AFF AT LEVEL 1 <br /> w _ _ _ �® \ w - • • w AND 9'-3" AFF AT LEVEL 8. CEILING HEIGHT ELEVATIONS W <br /> • w - _ O I \ i \ \ I \ WILL APPLY TO UNDERSIDE OF FLOOR ASSEMBLY. 1 <br /> \ O 1 \ \ EQ EQ T {� /2'-0", 0 6, 4„ 9. FOR UNITS ON LEVEL 1, DROPPED SOFFITS SHALL BE J W <br /> \ " a \ d / It N , LOCATED AT 8'-8" AFF, WITH A LOWER SOFFIT AT 7'-7" <br /> w / EQ / EQ / s /2 0 Xn ILI 9,_6" w T-T� W L-1 • L_1 _ a OCCURING AT KITCHEN CABINETS. FOR UNITS ON LEVEL w Q O <br /> d . 0 d d �. � _ L 2 8, DROPPED SOFFIT SHALL BE LOCATED AT 8'-6" AFF, W c0 <br /> \ w 5� w w \ \ U. : WITH A LOWER SOFFIT AT i'-7" OCCURING AT KITCHEN J O� <br /> -�J',}6- „ -f �+ - D t- . . ---- _ % / - _ CABINETS. w <br /> W T :. . �p-,1P L-1 L-1 �c /� a T-T' I J Q <br /> 50 \® —0 T <br /> • :® U.NO— CO 9 - • •50-0 ; _ F d '. (CFM 1 6 _ I -CPM I d 11. ALL GYP CEILINGS TO BE PT-1, U.N.O. <br /> w a w 71_7. I w O uj <br /> 11 w $ 12. REFER TO BUILDING SECTIONS & ASSEMBLIES FOR 0 <br /> - i 'el. <br /> el I I -. 9,-6„ I , I C I I: I �i, LL W <br /> • I I I I CEILING CONDITIONS <br /> �_ I, iiii \ I I \ I �— -- * UNIT NAMING LEGEND: CC O W <br /> I I I I I I I I ' A- STUDIOS N <br /> �EQ LEQ or �/ EQ I' EQ // EQ r EQ / EQ EQ / / EQ � EQ EQ 1,EQ EQ EQ EQ EQ EQ EQ EQ I EQ I B_ OPEN-1 BEDROOM <br /> �i �( �( ,1',>' / ,(/ —// / // ,t' .{' C- 1 BEDROOM O <br /> D 2 BEDROOM <br /> RCP LEGEND N N <br /> 6 D2 RCP � D2A TYPE 'A' RCP UNIT RCP ELEVATION (FF TO GWB <br /> CEILING) : <br /> A6.1 SCALE: 1/4" = 1'-0" \A6•9 SCALE: 1/4" = 1'-0" SEE BUILDING SECTIONS FOR <br /> INDICATED A.F.F. HT. <br /> RCP GWB SOFFIT <br /> SEE UNIT RCP FOR INDICATED A.F.F. HT. <br /> 0 RECESSED CAN LIGHT <br /> 5'-9 1/4" 11'-5" 9'-2 3/4" <br /> / / / / 6'-0" / 11'-5" / 9'-2 3/4" <br /> O <br /> S6 vir- <br /> u FOS O Al 62 0iifi FOS PENDANT LIGHT FIXTURE / J BOX <br /> \ \ d I i - n - ` t VANITY WALL SCONCE <br /> FOS' — n 'C \ FOS I l \ <br /> _ # _ '° _IL ( FOS 1 _ ± ! - J Q° J L_ _ c <br /> FOS 50 CFM <br /> 1I 1 RANGE EXHAUST <br /> I I I - - - J �6 � I - <br /> P10 I - I� 50CFM <br /> P10 10I 0 BATHROOM / LAUNDRY EXHAUST <br /> CI I O <br /> 00 IN <br /> SI ci I� C1 <br /> S3 <br /> a `1 O I`V CONC-1 a SMOKE DETECTOR & CARBON <br /> 6'-11" I I r SD �� <br /> in I - I- I wP-1 M / / I I CONC-1 CO MONOXIDE DETECTOR REGISTERED <br /> / 6'-11" / 1 I- 1 I D2_2-BED _ C X-75 I I I PT-1 <br /> \-..-) \ ARCHITECT <br /> \ 1 p`n i 1 i 889 SF ^ �� ��1P5 I I _ T SMOKE DETECTOR ONLY <br /> r ® I J D2 2BED TYPE A SD W sF W SHIRK <br /> _ - i 877 SF B4 STATE OF WASHHYGTON <br /> N �jC 4� I / 1I i� o ,L L- _ \ <br /> N \ 0 / 6 \ 7� J \ NI a <br /> 9 6 0 OoD CEILING MOUNTED FAN WITH LIGHT DATE: 01/25/21 <br /> 6 A6.26 SIM a �6.28 a O D JOB NO. 19 48 <br /> a �6� SIM A6.26 9 <br /> NI- <br /> let- - L - - <br /> a - - - - - - N PERMIT NO.B2006-044 <br /> N — — �� — — , \ / 3'-8 7/8" I ® 1 / ��� J 62009 01B <br /> ( l� )-- \v REVISIONS: <br /> O ® II X 2 I CX-4y O I : i l 1 KEY NOTES �+ <br /> \ ,, 11 i° I- <—�I F I 1 - 1 DATE DESCRIPTION <br /> 03 _ L_ 1\ in 4------- <br /> ✓ 9 04/08/21 IFC AD01/19/21 1D 01V 1 <br /> N. P4 _i -11- r VJ \ P5 iv \ a i I (� a O 30" x 48" CLEAR FLOOR SPACE 11 04/23/21 RFI046 <br /> 1— X1-9 c' P10 d L r- I ,0 1 t S1 -�� p4g a P10 1� 1 ��I�� P4 B4 <br /> a II� 1D. 1 niv o '� i I <br /> } co PONY WALL TO UNDER SIDE OF COUNTER <br /> E0 I a , _ / , 18" MIr II- - \ al P4 ti X i � p0, _f 4 23/' 1 i I 10 <br /> FOS / (cr all / y , \\ 1 I u , FOS 1 - \ I 8, MIq 1 ' P48 0 it° <br /> nt no - rn I ( ooc <br /> rir��� O 4 �\ J JI1I, rn JJ I �1 \ FOS \ �\ \ 0 4' ® I C\. J ` I \ ISSUE: <br /> FOS SHORING/EX 05/08/20 <br /> N V- 7 J _ _ - , N LL // <br /> °f I to 0 Rill PHASE I 06/22/20 <br /> / 3'-9 1/4" / 6'-6 1/2" 6'-0 1/2" / 5'-8 1/2" / 2'-5" / O u_ BID PROG SET 07/13/20 <br /> X u. 4-0 2-0 3'-10 1/4" 6-9 1/4 6'-3 1/2" -4 3/4 <br /> / 35'-61/4" V / / /35,_9„ / PHASE II 08/31/20 <br /> / / GMP 09/30/20 <br /> PERMIT REV 1 01/19/21 <br /> /2 D2_2-BED 3 D2A_TYPE 'A' - 2-BED IFC SET 02/19/21 <br /> \6.1 SCALE: 1/4" = 1'-0" \6•1 SCALE: 1/4" = 1'-0" PERMIT REV 2 02/19/21 <br /> IFC SET 02/19/21 <br /> PERMIT REV 3 05/26/21 <br /> D2 2BED D2A 2BED <br /> 102 205 ENLARGED <br /> 305 UNIT PLANS <br /> CITY OF EVERETT <br /> REVIEWED FOR PERMIT <br /> SHEET NO: <br /> A6 . 12 <br />