My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2701 ROCKEFELLER AVE 2020 Plans 2023-09-18
>
Address Records
>
ROCKEFELLER AVE
>
2701
>
Plans
>
2701 ROCKEFELLER AVE 2020 Plans 2023-09-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2023 7:52:15 AM
Creation date
7/8/2021 10:01:04 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2701
Permit
B2006-044
B2009-016
Year
2020
Notes
B2006-044 - CONCRETE WORK ONLY - FNDTN THRU LEVEL4 FLOOR SLAB B2009-016 - 8 STOREY MULTI-FAMILY W/ WOOD FRAME APARTMENTS - PH2
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
253
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> DOORS, DOORWAYS, AND GATES4. <br /> U) co <br /> ICC A117.1-2009 TABLE 404.2.3.2 - MANEUVERING CLEARANCES FOR MANUAL SWINGING DOORS °�° <br /> 404 DOORS, DOORWAYS, AND GATES rcJ <br /> TYPE OF USE MINIMUM CLEARANCES I co <br /> `� rnm <br /> 404.1 GENERAL. DOORS, DOORWAYS, AND GATES THAT ARE PART OF AN ACCESSIBLE ROUTE APPROACH PERPENDICULAR TO BEYOND LATCH I c <br /> • <br /> DOOR SIDE o N <br /> SHALL COMPLY WITH 404. DIRECTION `DOOR 1 PARALLEL TO DOOR a, rnLL <br /> N `E .c 2 <br /> 404.2 MANUAL DOORS, DOORWAYS, AND MANUAL GATES. MANUAL DOORS AND DOORWAYS AND FROM FRONT I PULL 60 INCHES (1525 MM) 18 INCHES (455 MM) 1__L 3 fo N <br /> • MANUAL GATES INTENDED FOR USER PASSAGE SHALLICOMPLY WITH 404.2. Q . N <br /> FROM FRONT PUSH 48 INCHES (1220 MM) 0 INCHES (0 MM)3 °' <br /> SHALL COMPLY WITH 404.2 3 AND <br /> DOUBLE-LEAF <br /> 404.2.1 DOORSGATES. AT LEAST <br /> F'ONE OTHE ACTIVE LEAVES OF DOORWAYS —_ o <br /> 04.2.4. FROM HINGED SIDE PULL 60 INCHES (1525 MM) 36 INCHES (915 MM) v <br /> WITH TWO LEAVES • <br /> CC) <br /> 404.2.2 CLEAR WIDTH. DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES (815 MM) FROM HINGED SIDE PULL 54 INCHES (1370 MM) 42 INCHES (1065 MM) V <br /> MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED <br /> BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. s 814L <br /> OPENINGS MORE THAN 24 INCHES (610 MM) DEEP SHALL PROVIDE A CLEAR OPENING OF 36 FROM HINGED SIDE PUSH 42 INCHES (1065 MM) 22 INCHES (1370 MM) <br /> INCHES (915 MM) MINIMUM. THERE SHALL BE NO PROJECTIONS INTO THE REQUIRED CLEAR t ,i.. x •• '.;: ,� 1 <br /> OPENING WIDTH LOWER THAN 34 INCHES (865 MM) ABOVE THE FINISH FLOOR OR GROUND. FROM LATCH SIDE PULL 48 INCHES (1220 MM) 24 INCHES (610 MM) " <br /> PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES (865 MM) AND 80 INCHES ocuHKi BARNES <br /> • <br /> (2030 MM) ABOVE THE FINISH FLOOR OR GROUND SHALL NOT EXCEED 4 INCHES (100 MM). FROM LATCH SIDE PUSH 42 INCHES (1065 MM)2 24 INCHES (610 MM) <br /> EXCEPTIONS: 1. DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES (1980 1 ADD 6 INCHES (150 MM) IF CLOSER AND LATCH PROVIDED. <br /> MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND. 2ADD 6 INCHES (150 MM) IF CLOSER PROVIDED. <br /> 3ADD 12 INCHES (305 MM) BEYOND LATCH IF CLOSER AND LATCH PROVIDED. <br /> 404.2.3 MANEUVERING CLEARANCES. MINIMUM MANEUVERING CLEARANCES AT DOORS SHALL a BEYOND HINGE SIDE. <br /> COMPLY WITH 404.2.3. MANEUVERING CLEARANCES AND SHALL INCLUDE THE FULL CLEAR <br /> OPENING WIDTH OF THE DOORWAY. REQUIRED DOOR MANEUVERING CLEARANCES SHALL NOT . <br /> INCLUDE KNEE AND TOE CLEARANCE. i <br /> • PULL SIDE PULL SIDE <br /> 404.2.3.1 FLOOR SURFACE. FLOOR SURFACE WITHIN THE MANEUVERING CLEARANCES SHALL r.i, <br /> HAVE A SLOPE NOT STEEPER THAN 1:48 AND SHALL COMPLY WITH SECTION 302. r -4- <br /> — — <br /> I <br /> 404.2.3.2 SWINGING DOORS. SWINGING DOORS AND SHALL HAVE MANEUVERING CLEARANCES Z 18" MIN. I • <br /> 24" PREFERRED I <br /> COMPLYING WITH TABLE 404.2.3.2. 1 �. X MIN. g • <br /> 404.2.3.3 SLIDING AND FOLDING DOORS. SLIDING DOORS AND FOLDING DOORS SHALL HAVE I" I I } W <br /> MANEUVERING CLEARANCES COMPLYING WITH TABLE 404.2.3.3. ♦ ..1 <br /> C <br /> 404.2.3.4 DOORWAYS WITHOUT DOORS. DOORWAYS WITHOUT DOORS THAT ARE LESS THAN 36 I . . <br /> W Q O <br /> INCHES (915 MM) IN WIDTH SHALL HAVE MANEUVERING' CLEARANCES COMPLYING WITH TABLE rNOTE: X =36" MIN. IF Y= I W O <br /> 404.2.3.4 j j 60". X= 42" MIN. IF Y=54". J <br /> 404.2.3.5 RECESSED DOORS. WHERE ANY OBSTRUCTION WITHIN 18 INCHES (455 MM) OF THE • • 4LW ]? <br /> LATCH SIDE OF A DOORWAY PROJECTS MORE THAN 8 INCHES (205 MM) BEYOND THE FACE OF THE 4 MI PUSH SIDE W <br /> DOOR, MEASURED PERPENDICULAR TO THE FACE OF THE DOOR, MANEUVERING CLEARANCES PULL SIDE 1 N o Y I- <br /> FOR A FORWARD APPROACH SHALL BE PROVIDED. I 12" MIN.* 22" MIN.y U W <br /> • <br /> r - - 7- - 1 I I '� "II Q 404.2.4 THRESHOLDS. IF PROVIDED, THRESHOLDS AT DOORWAYSw <br /> SHALL BE 1/2 INCH (13 MM) z 1 I I z -- r-- . . — r— - I O � W <br /> MAXIMUM IN HEIGHT. RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL I I I I I , I I <br /> COMPLY WITH SECTIONS 302 AND 303. I • 2 <br /> � I I _ <br /> W I I I • I It EtO W <br /> 404.2.5 TO DOORS IN SERIES. DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN SERIES } I I I . I I r N <br /> SHALL BE 48 INCHES (1220 MM) MINIMUM PLUS THE WIDTH OF ANY DOOR SWINGING INTO THE } <br /> SPACE. THE SPACE BETWEEN THE DOORS SHALL PROVIDE A TURNING SPACE COMPLYING WITH �a • , O <br /> SECTION 304. <br /> • <br /> 404.2.6 DOOR HARDWARE. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON 4 N <br /> ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO'GRASP WITH ONE HAND AND DOES <br /> OF NOTE: Y=54" MIN. I INOTE: Y = 48" MIN. IF DOOR HAS1 <br /> f <br /> NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTINGTHE WRIST TO OPERATE. OPERABLE <br /> PARTS OF SUCH HARDWARE SHALL BE 34 INCHES (865 MM) MINIMUM AND 48 INCHES (1220 MM) IF DOOR HAS CLOSER , BOTH A LATCH AND A CLOSER. <br /> MAXIMUM ABOVE THE FLOOR. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, * IF BOTH CLOSER AND LATCH <br /> xi <br /> OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. <br /> PROVIDED, <br /> EXCEPTION: LOCKS USED ONLY FOR SECURITY PURPOSES AND NOT USED FOR NORMAL • <br /> • <br /> OPERATION SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 404.2.6. • <br /> p �yPUSH SIDE (X) 24" t. <br /> 404.2.7.1 DOOR CLOSERS. DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN I XMIN.� PUSH SIDE . <br /> POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF 12 r T —— - r - — - — - I ♦ N. <br /> DEGREES SHALL BE 5 SECONDS MINIMUM. z I I n I I Z <br /> I I v I I I g <br /> 404.2.7.2 SPRING HINGES. DOOR SPRING HINGES SHALL BE ADJUSTED SO THAT FROM AN OPEN I' . I I . <br /> POSITION OF 70 DEGREES, THE DOOR SHALL MOVE TO'ITHE CLOSED POSITION IN 1.5 SECONDS d I' I , I I <br /> MINIMUM. t� . IIIIIIIIIII <br /> • <br /> 404.2.8 DOOR-OPENING FORCE. FIRE DOORS SHALL HAVE THE MINIMUM OPENING FORCE • , <br /> ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE FORCE FOR PUSHING OR • <br /> PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: 1. INTERIOR HINGED <br /> DOOR: <br /> POUNDS <br /> SLIDING <br /> OR <br /> FOLDING DOOR: 5.0 POUNDS (22.2 N) <br /> MAXIMUM. THESE FORCES DO NOT THE FORCE REQUIRED TO RETRACT LATCH BOLTS 1NOTE:X=12" MIN. IF DOOR HAS j NOTE:Y=48" MIN. IF DOOR HAS f. <br /> OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. ;BOTH A LATCH AND A CLOSER ( ! BOTH A LATCH AND A CLOSER) . . <br /> 404.2.9 DOOR SURFACE. DOOR SURFACES WITHIN 10 INCHES (255 MM) OF THE FLOOR, MEASURED " <br /> VERTICALLY, SHALL BE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF <br /> THE DOOR. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN SUCH SURFACE SHALL BE 32" MIN <br /> lj • . <br /> WITHIN 1/16 INCH (1.6 MM) OF THE SAME PLANE AS THE OTHER. CAVITIES CREATED BY ADDED CLEA • <br /> KICK PLATES SHALL BE CAPPED. CLEAR OPENINGS MUST BE BETWEEN THE <br /> r <br /> \ FLOOR IN ITS 90 DEGREE OPEN POSITION AND <br /> \ THE FACE OF THE STOP _ <br /> EXCEPTIONS: 1. SLIDING DOORS SHALL NOT BE REQUIRED O COMPLY WITH SECTION 404.2.9. 2. 90 .. ) REGISTERED <br /> TEMPERED GLASS DOORS WITHOUT STILES AND HAVING A BOTTOM RAIL OR SHOE WITH THE TOP ARCHITECT <br /> LEADING EDGE TAPERED AT NO LESS THAN 60 DEGREES FROM THE HORIZONTAL SHALL NOT BE I _ i - ��. � + <br /> REQUIRED TO COMPLY WITH THE 10-INCH (255 MM) BOTTOM RAIL HEIGHT REQUIREMENT. 3. STOP --" <br /> DOORS THAT DO NOT EXTEND TO WITHIN 10 INCHES (255 MM OF THE FLOOR SHALL NOT BE gg W &COT U CRK <br /> I STATE OF WASHINGTON <br /> REQUIRED TO COMPLY WITH SECTION 404.2.9. 4 • .. <br /> NOTE: ALL DOORS IN ALCOVES SHALL COMPLY WITH THE <br /> 404.2.10 VISION LITES. DOORS AND SIDELITES ADJACENT TO,DOORS CONTAINING ONE OR MORE CLEARANCES FOR FRONT APPROACHES. a. <br /> GLAZING PANELS THAT PERMIT VIEWING THROUGH THE PANELS SHALL HAVE THE BOTTOM OF AT If <br /> 4 DATE: 01/25/21 <br /> • <br /> LEAST ONE PANEL ON EITHER THE DOOR OR AN ADJACENT SIDELITE 43 INCHES (1090 MM) tJOB NO. 19 48 <br /> MAXIMUM ABOVE THE FLOOR. I 1. THE FLOOR OR LANDING ON EA. SIDE OF AN EXIT DOOR SHALL BE LEVEL AND CLEAR. PERMIT NO.B2006-044 <br /> I THE LEVEL AREA SHALL HAVE A LENGTH IN THE DIRECTION OF THE DOOR SWING OF AT 62009 016 <br /> EXCEPTION: VISION LITES WITH THE LOWEST PART MORE THAN 66 INCHES (1675 MM) ABOVE THE LEAST 60" AND LENGTH OPPOSITE THE DIRECTION OF DOOR SWING 44" AS MEASURED AT <br /> FLOOR SHALL NOT BE REQUIRED TO COMPLY WITH SECTION'404.2.10. RIGHT ANGLES TO THE PLANE OF THE FLOOR IN ITS CLOSED POSITION. REVISIONS: <br /> 404.3 AUTOMATIC DOORS. AUTOMATIC DOORS AND AUTOMATIC GATES SHALL COMPLY WITH 2. THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL ' ` .. DATE DESCRIPTION <br /> SECTION 404.3. FULL POWERED AUTOMATIC DOORS SHALL COMPLY WITH ANSI/BHMA A156.10 EXTEND 24" PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18" PAST <br /> LISTED IN SECTION 105.2.4. POWER-ASSIST AND LOW-ENERGY DOORS SHALL COMPLY WITH THE STRIKE EDGE FOR INTERIOR DOORS. 4 <br /> ANSI/BHMA A156.19 LISTED IN SECTION 105.2.3. I <br /> EXCEPTION: DOORS, DOORWAYS, AND GATES DESIGNED TO BE OPERATED ONLY BY SECURITY - o ' <br /> PERSONNEL SHALL NOT BE REQUIRED TO COMPLY WITH SECTIONS 404.3.2, 404.3.4, AND 404.3.5. REQUIRED I NOTE: PROVIDE BUMPER IN <I <br /> I POCKET TO PREVENT DOOR <br /> 404.3.1 CLEAR WIDTH. DOORWAYS SHALL HAVE A CLEAR OPENING WIDTH OF 32 INCHES 815 MM) I SPACE 18" MIN. FROM FULLY RECEDING <br /> ( I '--,N 24" PREFERRED <br /> IN POWER-ON AND POWER-OFF MODE. THE MINIMUM CLEAR OPENING FOR AUTOMATIC DOOR I 32" MINI. <br /> SYSTEMS SHALL BE BASED ON THE CLEAR OPENING WIDTH PROVIDED WITH ALL LEAFS IN THE I \ I / - !- t <br /> OPEN POSITION. 1! ISSUE; • <br /> L =` I I * SHORING/EX 05/08/20 <br /> 404.3.2 MANEUVERING CLEARANCES. MANEUVERING CLEARANCES AT POWER-ASSISTED DOORS REQUIRED NOTE: X = 12° \ j PHASE I 06/22/20 • <br /> SHALL COMPLY WITH 404.2.3. CLEAR STOP <br /> SPACE WITH CLOSER t, BID PROG SET 07/13/20 <br /> • <br /> 404.3.3 THRESHOLDS. THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH AND LATCHSET PHASE II 08/31/20 <br /> SECTION 404.2.4. I <br /> GMP 09/30/20 <br /> ALL LEVEL DOOR HANDLES ARE TO OPERATE AT A FORCE NO GREATER ALL REV 1 01/19/21 <br /> 404.3.4 TWO DOORS IN SERIES. DOORS IN SERIES SHALL COMPLY WITH SECTION 404.2.5. IFC SET 01/25/21 <br /> THAN A SLB. FORCE AND WITHOUT EXCESSIVE BODY MOVEMENT OR PERMIT REV 2 02/19/21 <br /> SPECIAL KNOWLEDGE. LEVELS TO BE OPERABLE WITH ONE HAND AND NOT <br /> • 404.3.5 CONTROL SWITCHES. MANUALLY OPERATED CONTROL SWITCHES SHALL COMPLY WITH REQUIRE GRASPING, PINCHING OR TWISTING. DOORS TO SWING AND BE IFC SET 02/19/21 <br /> SECTION 309. THE CLEAR FLOOR SPACE ADJACENT TO THE CONTROL SWITCH SHALL BE LOCATED OPERABLE AT A FORCE NO GREATER THAN SLB. ALL DOORS MUST PROVIDE PERMIT REV 3 05/26/21 <br /> BEYOND THE ARC OF THE DOOR. MINIMUM MANEUVERING CLEARANCES. <br /> ADA DOOR <br /> AUTOMATIC CLOSER - <br /> (IF NEC) \-�, CI i Y OT VERETT <br /> • <br /> ROOM IDENTIFICATION REVIEWED FOR PERMIT <br /> (IF NEC) <br /> VIEWING PANEL — <br /> (IF NEC) : 1 <br /> LEVEL DOOR HANDLE _ g SHEET NO: <br /> o f '1 In <br /> • \l'el. - <br /> NOTE: THRESHOLD P <br /> �, <br /> MAX. HT. 1/2" A.F.F. M <br /> Ns' <br /> I A8 . 03 <br /> REFERENCE CODE: NOTE: FLOOR MAT FLUSH 32" MIN. <br /> ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES WITH FINISHED FLOOR / <br /> ICC A117.1-2009: 1 <br /> i <br />