My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
902 PINE ST NORTH SOUND BEHAVIORAL HEALTH TREATMENT CENTER 2025-11-04
>
Address Records
>
PINE ST
>
902
>
NORTH SOUND BEHAVIORAL HEALTH TREATMENT CENTER
>
902 PINE ST NORTH SOUND BEHAVIORAL HEALTH TREATMENT CENTER 2025-11-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2025 1:37:49 PM
Creation date
7/13/2021 1:43:06 PM
Metadata
Fields
Template:
Address Document
Street Name
PINE ST
Street Number
902
Tenant Name
NORTH SOUND BEHAVIORAL HEALTH TREATMENT CENTER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
328
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAFETY PRECAUTIONS PERIODIC INSPECTION <br /> 1. Disconnect and lockout the electrical supply to Periodic inspection of the pump should be <br /> the motor before working on the unit,or if performed at six month intervals. The pump should <br /> maintenance is to be performed on the pump in a be cleaned of accumulated abrasive particles and <br /> flooded area. debris. The wet well should also be cleaned of <br /> 2. Exercise caution when working in the exposed accumulated abrasive particles. <br /> areas of the rotating parts. <br /> 3. In case of severe vibration or unusual noise,shut Check the motor housing and the seal chamber for <br /> off pump at once and determine the cause. moisture in the following manner: <br /> 4. If frequent tripping of the overload protection <br /> occurs,troubleshoot the pump to correct the 1. Place the pump in a horizontal position in a V- <br /> problem. block chamber with the seal chamber plugs <br /> facing downward. <br /> TROUBLESHOOTING PUMP 2. Remove the plugs and drain the content of the <br /> seal chamber in a transparent container and <br /> Problem Probable Cause allow the draied liquid to settle. <br /> Insufficient or 1. Blown fuses or open circuit 3. If no water settles to the bottom of the container, <br /> No Water Flow breakers the chamber can be refilled with clean oil and <br /> 2. Poor switch contact the plugs replaced. <br /> 3. Discharge head too high <br /> 4. Clogged or damaged impeller 4. If water settles in the container,the source of the <br /> 5. Binding shaft liquid must be determined and worn and/or <br /> 6. Check or gate valve closed damaged seals,0-rings,etc.must be replaced. <br /> 7. Water level below casing 5. Turn the pump over,remove the motor shell <br /> Insufficient Pressure 1. Low voltage plug,drain the motor houseing into a transparent <br /> 2. Clogged or damaged impeller container. <br /> 3. Motor incorrectly wired 6. If no liquid is present,replace the plug. <br /> 4. Pump may be air-bound <br /> 7. If oil or oil and water are present,the upper seal <br /> Noisy or Vibrating 1. Misaligned or bent shaft must be inspected. <br /> Pump 2. Worn bearings <br /> 3. Lack of lubrication 8. If only water is present the leakage source is <br /> 4. Water level below casing most likly in the motor housing and the <br /> 5. Impeller rubbing or damaged condition of the 0-rings and/or the cable seal <br /> 6. Clogged impeller should be checked. <br /> NOTE REPLACEMENT PUMPS <br /> Submersible motors have an air relief slot on the Single phase units have starting modules built into <br /> lower mounting flange area. This slot is to prevent the motor. When replaceing exsiting pumps,check <br /> air lock.Under normal operation water will spray for any exsiting external modules,control panel <br /> out of the air relief slot.The normal water level mounted or seperatly mounted.These must be <br /> should be above the slot at shut off. removed or bypassed for proper operation of the <br /> pumping unit. <br /> IMPORTANT NOTICE <br /> For warranty consideration contact your local Weil <br /> representative before disassembly or repair. <br /> NOTE <br /> See separate instructions for pump assembly and <br /> disassembly. <br /> ---� WEIL PUMP <br /> A WILO COMPANY <br /> EM-1600-4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.