• <br /> WEIL CEDA 3/25/2019 7:43 AM H8150-T12 Layout 3-Phase MS-TL EXP Mtr's .dwg <br /> PANEL NAME Installer to Supply an appropriate power supply Caution: Connection of any other device to the <br /> PLATE INCLUDES: < ` . And Branch Circuit Protection to panel Control Power Source of this Panel will cause <br /> -system Voltage NEU[1 '�- L. � <br /> g 208v nl T. in accordance with Article 504 of the National improper operation and Void the Warranty. <br /> -Motor Amp Range 230V p1 �I i�i Electrical Code and Local Codes. <br /> -Phase Panel Amps 460v at ri 1 7 Fuses(LP-J or Equivalent)For Branch Circuit Moisture Sensor: If water enters the motor <br /> -Enclosure Type I a�''�-� Protection: 1.25 X Full load amps of both the Sensor Indicator Light will illuminate and the motor <br /> ---_1 Motors;Plus 1 Amp for Control Power. control circuit will open. The motor control circuit <br /> Control Transformer Is When changing panel voltage <br /> Connected For Proper Connect This wire To Dotted lines(- -)represent Field will remain open and the light will remain illuminated <br /> Line Voltage At Factory Appropriate Line Voltage Terminal Connections. until the leakage condition is corrected. Test the <br /> O ®®®®®® O Wire Colors: Black=Power Green=Ground sensor circuit by depressing the test push-button. <br /> 12 a l0 9 B T Red=Control White=Common(Neutral) the light will illuminate and the motor circuit will open. <br /> Float Connections may not be LEVEL SW TCH INPUT STATUS When the push-button is released the indicator light <br /> PAu HIGH WATER• Yellow=Isolated Contacts <br /> changed. Must go on In order LEVEL(LSA) will go off and the motor control circuit will close. <br /> rESTi Blue=Intrinsically Safe Circuits TempLimiter(Over Temperature): <br /> and off in reverse order.When out ®CLEAR ISR 1 LAG(LS3)%� Pump should rotate in the direction of the Arrow If p )' <br /> of order or a float isn't working an LOAD vTO UL Listed LEAD(LS2))CI: on the pump case. Change rotation of the tot1130 Degrees Celsius temperaturehe internal 266 Degrees Fahrenheit) <br /> alarm will sound. STOP/ b, pump at the control panel. Interchange wires: the motor control circuit will open and the over <br /> LOAD 2 LOAD 2 LOAD 1 OFF(LSA), I> <br /> The lights on the right side of ISR Aux OFF• Tl And T2 On M1 For Pump 1. temperature light will illuminate. The motor control <br /> g0 SAFE I P(LSA) GG TiAnd T2 On M2 For Pump2. circuit will remain open and the light illuminated until <br /> relaywill showyou which float is <br /> INTRINSICALLY INPUTS Wires are Individually Numbered. the motor temperature drops below 82 Degrees <br /> Out of order or not working. 6®®®®® 1 Celsius(179 degrees Fahrenheit). <br /> MI&M2=Motor Contactors <br /> MP &MP2=Motor Circuit Protectors ISR Wires: A Separate Conduit or Raceway Must Be <br /> 5 WIRE SENSOR Connections: PBA=Mann Test Used For The Intrinsically Safe Wires Between a <br /> SS1&SS2=Spring Return Test To Off Junction Box and The Panel. <br /> Add Jumpers to TB2: #21 to 22&25; <br /> #23 to 24 and #26 to 27 ®=Component Coil OPTIONAL ALARM LIGHT <br /> 0 =Numbers on Terminal Blocks(TB1 or TB2). A10^- - Wht <br /> Pump 1:Red wire to#21 Orange to#23 0=Numbers on Components. <br /> OpenComponents. <br /> Black wire to#10 White wire to#37 <br /> I I =Normally Contact on Com onents. <br /> Pump 2: Red wire to#21 Orange to#26 \1 =Normally Closed Contact on Components. OPTIONAL r--Ll SYSTEM <br /> ALARM LIGHT L2 POWER <br /> Black wire to#10 White wire to#47 r- L3 <br /> OUTER DOOR NOT SHOWN r-- SUPPLY <br /> `Connect ALL Green Wires to Ground.J INTERIOR VIEW r--GRD 3-Phase <br /> (44. (LTI1:, - (LTII 1 <br /> CONNECTIONS <br /> NON HAZARDOUSM AREA r ' - ' ` <br /> ' Ti SAFE Mann <br /> ` <br /> .,., l Li v[) �`,sca INTRINSICALLY sw <br /> CONNECTIONS Ml M2 COVER VIEW a �o � 7jl O <br /> --fir. —�I- .,.,.• . . -� <br /> HAZARDOUS T1T2T3 O T1T2T3 O ) zoavi 1 _o GRD$ I I I D <br /> + + HORN <br /> %',MINI. 230V[.l I I <br /> AREA Ti ,2141E JI (AD) 460V rA 1 = I I I <br /> LI L3 <br /> T2 I I CON aoLPoWER ro o e c 3c <br /> PUMP T3 J I 1 420 s�A' ° `� t <br /> MOTORI GRD ----J I LT1 TJ ouch <br /> LTA PBA '• 4 a Y -: DSl <br /> n <br /> gMIWWWWIC <br /> Tl J PnMP P ♦►Mo1 S'.' <br /> O <br /> T2J LT3 SSI LT4 SS2 j, iJ NOTSSY =GRD ®, Wit.P:, __ IR UIT - <br /> J . :W: arx G � <br /> LT5 uLTr uLT6 eLTB 0IIWSR ypp.. Ccm�mnuMsy TB2 R,' .0.•� <br /> PUMP I PUMP 2, 4 R'R,5^ 'rlveivieS7 <br /> NON HAZARDOUS AREA ,O O 0 O i�.I1l W. ' <br /> morrame SEM.. Morsruae SENSOR WP11953 MI M2 <br /> INTRINSICALLY SAFE LT9 PBI LTIO PB2 <br /> CONNECTIONS FOR USE IN 81/8"Minim m <br /> CLASS 1 GROUPS C&D IC,LL `/ ) WPu952 .7 <br /> D <br /> CLASS 2 GROUPS E,F,&G SAFE�r IEI tiEigiO <br /> INTRINSICALLY 0 <br /> WP11954%44 ilIM 8150 SAFE CIRCUITS <br /> Install in accordance \•__ WP11955 / c, <br /> with art.504 of the E©0 CONNECT EACH WIRE TO MATCHING <br /> National Electric code, RIC CAUTION: Bonding between conduit <br /> only to purely resistive connection is not automatic and must be NUMBER ON TERMINAL BLOCKS, /TB2- <br /> C©� OR BOTTOM OF M1&M2. S 21 9 <br /> non-engery storing En: Provided as part of the Installation. <br /> devices. 8 1/8"MINIMUM 9 22 9 <br /> Intrinsically Safe : 4 9 23 9 <br /> \ <br /> Connections C©0 ) HAZARDOUS AREA FIELD CONNECTIONS 9 24 9 <br /> 8230s 4 Level Switch System i White <br /> Red - 9 25 9 <br /> I �r White 9 26 9 <br /> 14 HIGH WATER 1 1,-23 Black_ _.1 ( Red �� 9 27 9 <br /> Bllc �- t 5 I1 25 Isolated Contacts�' LSA 1 24__Orange--1 i 26 Black _i HIGH WATER=AR' 9 10 9 <br /> A 1 10 Blk/Wht _� ( Orange_; R1 I �lFl 9 37 9 <br /> _k ( STANDBY wh�t 37 Blue .1 f ® Blk/Wht 10 REMOTE PANEL -- 9 47 9 <br /> • _ 8301K2010 <br /> 1 LS3 --- h—C1 i^ Grd Green ) i 10 Blue � CRI=POWER OFF• - 9A109 <br /> 1 r 47 Grd Green) 70 71 9 Wht 9 <br /> I HIGH WATER-AR <br /> START SENSOR CABLE SENSOR CABLE F 72 9 R1 9 <br /> . I Blk o-Wht 3 GREEN GREEN Ml=PUMP 1 ON — <br /> LS2 Blk Blk/Wht Whtl Bic Blk/wht I 73 9 R2 9 <br /> I 1n 9R39 <br /> I Red OrgBlu Red Org Blu PUMP 2 ON=M2 <br /> STOP <br /> 111 r�r---��I""" 74 <br /> im �� l Mk O- 1 L I- ' 'd T1.SI s TS2 9 R5 9 <br /> • I LS u Moisture Sensors OVERTEMP Moisture Sensors OVERTEMP Customer To Supply Power for 9 R6 9 <br /> Maximum Cable Length is 120 Feet Pump 1 Motor Shell Pump 2 Motor Shell Operation Of External Device's <br />