I
<br /> I
<br /> I SHALLOW FOOTINGS WITH INTERIOR SLAB-ON-GRADE
<br /> I 1
<br /> • Typical Framing
<br /> Compacted Impervious Soil •'•• 1
<br /> (12 inch minimum) • '!`1,l Floor Slab
<br /> I (2inchminimum) •,',•1'.•, ,-i•,-,-,','i•,•,',`x•, ,-,'3',`
<br /> ',','1''', !'t'!n! ,t1`' I',"!'.! 1'1=1':,' Va or Barrier
<br /> Slope to drain away
<br /> from structure. _ — , 1-`-h•4•4•4•4.4.4 4•4 4�4.4.4. .4E4.4.4 4�4�4•4.4.44•4+4•4••�•4•
<br /> rrrrrrrr•rrrrrrrrrrrrrrrrrr=rr•r
<br /> •;•j• •• 1. 4.•.•44.44444444'. 4•%444•44444444•44•
<br /> <— •r•rrrrrrr•rrrrrr rrrrr rrrrrrrr•1
<br /> '1 1 s
<br /> F4Nry•,•i•,•-,3•'::•••••••.:::.:-;..%-**::.-4••..*:-:::.:%;:.:*:1::•:::-.`.1.-.;;'':.:::::;*:-.:.;*:.;:`iiiplr
<br /> , , ,
<br /> I /
<br /> I
<br /> # # `,•!•! Coarse Gravel Capillary Break
<br /> (6 inch minimum typically clear crushed)
<br /> I Suitable Soil /
<br /> / 461 ',',',-r:
<br /> / fi , ,-, Free Draining Sand
<br /> „4.4 . ram 1 ! 1 ?-I and Gravel Fill
<br /> Approved Non-woven / ff4�•••4O '� 1`1`1'1`■'1,1`1'11} -.=='r.:=='.
<br /> Geotextile Filter Fabric . ♦f�,i 0 •,','1 1 1 1 1�1 1 1
<br /> (18inchminimumfabriclap) /�4 I W.�#1 '`�:!',•` .`°`, 1
<br /> s.
<br /> o`�:J / /7 4 Suitable Soil
<br /> I Drainage Material
<br /> (Drain Rock or Clear
<br /> Crushed Rock w/no fines) Appropriate Waterproofing
<br /> Applied to Exterior of Wall
<br /> I Four Inch Diameter, Perforated,Rigid PVC Pipe
<br /> (Perforations oriented down,wrapped in non-woven
<br /> geotextile filter fabric,directed to suitable discharge)
<br /> I
<br /> I Notes:
<br /> Footings Should be properly buried for frost protection in accordance with
<br /> International Building Code or local building codes
<br /> I (Typically 18 inches below exterior finished grades)
<br /> The footing drain will need to be modified from this typical drawing to fit the
<br /> Idimensions of the planned monolithic footing and slab configuration
<br /> IDate: 11-518 By: EB Scale: None Project
<br /> GEOTEST SERVICES, INC. TYPICAL FOOTING &WALL DRAIN SECTION 18-0770
<br /> 741 Marine Drive
<br /> I Bellingham, WA 98225 NORTH PUGET SOUND BEHAVIORAL HEALTH Figure
<br /> phone: (360)733-7318 TREATMENT CENTER ADDITION fax: (360)733-7418 2801 10TH STREET-EVERETT,WA 3
<br /> I
<br />
|