My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7505 SEAWAY BLVD BUS SHELTER 9 2021-07-20
>
Address Records
>
SEAWAY BLVD
>
7505
>
BUS SHELTER 9
>
7505 SEAWAY BLVD BUS SHELTER 9 2021-07-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2021 8:27:16 AM
Creation date
7/13/2021 2:20:22 PM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
7505
Tenant Name
BUS SHELTER 9
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYMBOLS: <br /> ABBREVIATIONS: GENERAL NOTES: <br /> ALUM ALUMINUM SIM SIMILAR DETAIL DESIGNATOR <br /> AFF ABOVE FINISHED FLOOR SJ SCORE JOINT 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 2015 INTERNATIONAL BUILDING CODE. A COPY OF THE APPROVED PLAN SHALL BE <br /> ARCH ARCHITECT,ARCHITECTURE SOG SLAB ON GRADE ON SITE WHENEVER CONSTRUCTION IS IN PROGRESS. <br /> @ AT SST STAINLESS STEEL r 1 <br /> AVE AVENUE STRUCT STRUCTURE OR STRUCTURAL I I 2. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN <br /> BATT BATTEN THK THICK,OR THICKNESS I I AND TO FURTHER DISCOVER AND AVOID HARM TO ANY OTHER BUILDING UTILITIES NOT SHOWN HEREIN WHICH MAY BE AFFECTED BY <br /> BLD BUILDING TOC TOP OF CURB AftJ THE IMPLEMENTATION OF THIS PLAN. <br /> B.O.S. BOTTOM OF STRUCTURE TOR TOP OF RAIL AREA OF IMAGE <br /> BOT BOTTOM TRD TREAD )�� 3. THE CONTRACTOR SHALL TAKE APPROPRIATE STEPS REQUIRED TO PROTECT EXISTING UTILITIES,EQUIPMENT OR BUILT-IN FURNISHINGS <br /> CAB CABINET TYP TYPICAL REMAINING IN THE WORK AREA DURING CONSTRUCTION. <br /> CCTV CLOSED CIRCUIT TELEVISION UNO UNLESS NOTED OTHERWISE SHEET NUMBER WHERE <br /> CES CUSTOMER EMERGENCY STATION VERT VERTICAL THE DETAIL IS SHOWN 4. ALL DEMOLITION DEBRIS SHALL BE LEGALLY DISPOSED OF,OFF SITE. <br /> CIP CAST IN PLACE VIF VERIFY IN FIELD (DASH IF ON SAME SHEET ONLY) <br /> CJ CONSTRUCTION JOINT W/ WITH 5. DO NOT SCALE THE DRAWINGS. <br /> COL COLUMN W/O WITHOUT <br /> COMM COMMUNICATION(S) 9. OVERALL DIMENSIONS INDICATED ARE TO FINISH SURFACES OR STRUCTURAL GRID-LINES AND OTHER DIMENSIONS ARE TO FACE OF <br /> CONC CONCRETE CAST IN PLACE CONCRETE,OR FACE OF STRUCTURE UNLESS NOTED OTHERWISE. <br /> CONST CONSTRUCTION <br /> CONT CONTINUOUS SYMBOLS: 10. DRAWING SCALES SHOWN ARE BASED ON A SHEET SIZE OF 34 X 22 INCHES.IF THE PRINTED SHEET SIZE IS 17 X 11 INCHES,THEN THE <br /> D DEPTH DRAWINGS HAVE BEEN REDUCED TO HALF THE SCALE INDICATED. <br /> DET,DTL DETAIL <br /> DIA DIAMETER DRAWING DESIGNATOR 11. THE DRAWINGS AND SPECIFICATIONS TOGETHER COMPRISE THE CONSTRUCTION DOCUMENTS. ANY DISCREPANCIES BETWEEN THEM <br /> DIM DIMENSION OR BETWEEN TWO OR MORE DRAWINGS SHALL BE REFERRED TO THE RESIDENT ENGINEER BEFORE ANY WORK AFFECTED IS <br /> DN DOWN X DRAWING TITLE/NAME PERFORMED. • <br /> DWG(S) DRAWING(S) <br /> EA EACH XXXXX SCALE: 12. SEE CIVIL DRAWINGS FOR LAYOUT AND DETAILS OF PAVEMENTS AND CURBS. <br /> EJ EXPANSION JOINT `-/ <br /> ELEV ELEVATION SHEET NUMBER WHERE DRAWING 13. SEE DRAINAGE DRAWINGS FOR UNDERGROUND PIPING INFORMATION. <br /> ELEC ELECTRICAL IS CALLED OUT GRAPHICS LEGEND: <br /> EQ EQUAL 14. SEE STRUCTURAL DRAWINGS FOR STRUCTURAL ELEMENTS AND ATTACHMENT INFORMATION. <br /> EXIST EXISTING <br /> EXT EXTERIOR DRAWING DESIGNATOR • CIP CONCRETE(PLAN,SECTION,AND 15. SEE MECHANICAL DRAWINGS FOR MECHANICAL AND PLUMBING INFORMATION. <br /> FE FIRE EXTINGUISHER ELEVATION) <br /> FEC FIRE EXTINGUISHER CABINET 16. SEE ELECTRICAL DRAWINGS FOR TYPE OF INTERIOR LIGHTING LOCATION,SEE CIVIL DRAWINGS FOR EXTERIOR LIGHTING LOCATIONS <br /> FIXT FIXTURE <br /> FT O.C. FOOT OR FEET <br /> OF CONCRETE OR FACE OF CURB DRAWING TITLE/NAME PRECAST CONCRETE(PLAN,SECTION, 17. FOR COLORS AND FINISHES,SEE SPEC 09 06 00 COLORS AND FINISHES SCHEDULE.BRING ANY DISCREPANCIES BETWEEN <br /> AND ELEVATION) SPECIFICATION SECTIONS AND BETWEEN SPECS AND DRAWINGS TO THE ATTENTION OF THE OWNER. <br /> F.O.I.C. FURNISHED BY OWNER,INSTALLED BY CONTRACTOR - SCALE: <br /> F.O.S. FACE OF STEEL 18. PROVIDE 8 FOOT MINIMUM CLEARANCE FROM GRADE TO UNDERSIDE OF CANOPY STRUCTURE. <br /> GA GAUGE MORTAR/GROUT FILL <br /> GALV GALVANIZED DRAWING SHOWN ON <br /> o GL GLASS SAME SHEET ONLY <br /> 4 GWB GYPSUM WALL BOARD <br /> HDWR HARDWARE / STEEL SHEET LIST TABLE PROJECT INFORMATION <br /> a HORZ HORIZONTAL SECTION DESIGNATOR <br /> 5 HR HOUR Sheet Number Sheet Title 2015 INTERNATIONAL BUILDING CODE <br /> HM HOLLOW METAL jjj ALUMINUM A0.1 LEGEND&ABBREVIATIONS OCCUPANCY pI G( <br /> w HSS HOLLOW STRUCTURAL SECTION(STEEL) BUILDING CONSTRUCTION:V a <br /> HT HEIGHT airi J A1.0 SITE PLAN OC C LOAD i Zy <br /> IBC INTERNATIONAL BUILDING CODE XXXXXX A3.0 FULL SHELTER <br /> E IN INCH N..........""-SHEET NUMBER WHERE THE RIGID INSULATION (PLAN AND SECTION) A3.1 NARROW SHELTER PROJECT INCLUDES: <br /> INFO INFORMATION SECTION IS SHOWN • <br /> INSUL INSULATION A3.2 SHELTER SECTIONS �tTTuECSHELItR9- <br /> i'S1- <br /> • JB JUNCTION BOX A3.3 SHELTER DETAILS <br /> JT JOINT CONTINUOUS BLOCKING (4)NARROW SHELTERS: <br /> A3.4 SHELTER DETAILS <br /> 'y LED LIGHT-EMITTING DIODE ELEVATION DESIGNATOR 120 SF <br /> MAX MAXIMUM A4.0 PLANS AND ELEVATIONS <br /> MECH MECHANICAL A4.1 WIND SCREEN DETAILS <br /> MFR MANUFACTURER dal NON CONTINUOUS BLOCKING <br /> o MIN MINIMUM <br /> MOW MAINTENANCE OF WAY J <br /> NOTMETAL SHEET NUMBER WHERE THE SEALANT AND BACKER ROD <br /> • N/A APPLICABLE ���111 <br /> r NIC NOT IN CONTRACT ELEVATION IS SHOWN <br /> - NO NUMBER <br /> S N.T.S NOT TO SCALE <br /> 0/ OVER j GLASS/GLASS BLOCK <br /> El, OC ON CENTER DETAIL DESIGNATOR <br /> Ig OPNG OPENING <br /> OPP OPPOSITE <br /> h PET PHONE&TELEPHONE QIA DETAIL <br /> TACTILE WARNING TILE <br /> PC PRECAST XXXXX SCALE: <br /> PERF PERFORATED ��� <br /> PERIM PERIMETER <br /> PGL PROFILE GRADE LEVEL SHEET NUMBER WHERE THE <br /> PLYWD PLYWOOD DETAIL IS SHOWN <br /> o PLAT PLATFORM <br /> Ti PRV PRESSURE REDUCING VALVE <br /> I PT PAINT DETAIL DESIGNATOR CITY OF EVERETT <br /> g R RADIUS OR RISER <br /> of RCP REFL CTED CEILING PLAN X DETAIL REVIEWED FOR PERMIT <br /> REQD REQUIRED <br /> ▪ RO ROUGH OPENING SCALE: <br /> SECT SECTION DETAIL SHOWN ON THE <br /> • SHT SHEET SAME SHEET ONLY <br /> 38W [ Drawn By Date SCALE COMMUNITY TRANSIT Drawing No. <br /> `O rl IBI GROUP --__ REGISTER KC 9 w 19 AO. 1 <br /> 801 Second Avenue-Suite 1000 D`- `o o � ARC PERMIT Dented By 9/30/19 Hodr Nrs SEAWAY TRANSIT CENTER — SHELTER ADDITIONS <br /> I B I Seattle WA 98104 USA COmmunitytransi� Checked _ <br /> o tel 206 521 9091 fax 206 521 9095 1y�c GR RY L HILL SETBy Vert sneer Na. <br /> H Sn1,le S STA F wASHMGTON GH 9/30/19 N/A ✓ r <br /> Na. Date Revision APFr ibigroup.com <br /> Pro20ject <br /> Name 1 <br /> 8 Approved By Project Number 7,END & ABBREVIATIONS 9 <br /> of Total <br />
The URL can be used to link to this page
Your browser does not support the video tag.