• • <br /> Prescriptive Energy Code Compliance for All Climate Zones in Washington <br /> Project Information Contact Information <br /> 1108 Wall Street Marshall Ryan <br /> Everett, WA 98201 425-405-2326 <br /> This project will use the requirements of the Prescriptive Path below and incorporate the <br /> the minimum values listed.In addition,based on the size of the structure,the appropriate <br /> number of additional credits are rec '1 chosen by the pplicant. <br /> Authorized Representative �i,,/' /. Date /2 — ? 3 v <br /> All Climate Zones <br /> R-Valuea U-Factora O <br /> Fenestration U-Factorb n/a 0.30 , <br /> Skylight U-Factor n/a 0.50 C.);' <br /> Glazed Fenestration SHGCb,e n/a n/a e)% NV i <br /> Ceilingk 49j 0.026 ,t ;' Q , .4 ".j\..\ <br /> Wood Frame Wallg,m,n 21 int 0.056 Or t..i, �� <0�0 Z <br /> Mass Wall R-Valuei 21/21h 0.056 (.%),,,�,Q <br /> Floor 30g 0.029 i i'j�,�>:,›, <br /> Below Grade Wallc,m 10/15/21 int+TB 0.042 " <br /> Slabd R-Value&Depth 10, 2 ft n/a <br /> `Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. <br /> Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to <br /> achieve the following minimum number of credits: <br /> 1.Small Dwelling Unit: 1.5 credits <br /> Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of <br /> fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area <br /> but less than 1500 square feet. <br /> 2.Medium Dwelling Unit: 3.5 credits <br /> All dwelling units that are not included in#1 or#3. Exception: Dwelling units serving R-2 occupancies <br /> shall require 2.5 credits. <br /> 3. Large Dwelling Unit: 4.5 credits <br /> Dwelling units exceeding 5000 square feet of conditioned floor area. <br /> 4. Additions less than 500 square feet: .5 credits <br /> Table R406.2 Summary <br /> Option Description Credit(s) <br /> la Efficient Building Envelope la 0.5 ) F®+ <br /> lb Efficient Building Envelope lb 1.0 a " <br /> lc Efficient Building Envelope 1c 2.0 ] nr, v <br /> 1d Efficient Building Envelope 1d 0.5 ;r U <br /> 2a Air Leakage Control and Efficient Ventilation 2a 0.5 N <br /> 2b Air Leakage Control and Efficient Ventilation 2b 1.0 gi o U) <br /> 2c Air Leakage Control and Efficient Ventilation 2c 1.5 6 <br /> 3a High Efficiency HVAC 3a 1.0 '1, -z <br /> >ai lb <br /> 3b High Efficiency HVAC 3b 1.0 =t <br /> 3c High Efficiency HVAC 3c 1.5 <br /> 3d High Efficiency HVAC 3d 1.0 <br /> 4 High Efficiency HVAC Distribution System 1.0 <br /> 5a Efficient Water Heating 5a 0.5 0.5 ��, <br /> 5b Efficient Water Heating 5b 1.0 r' / <br /> 1/15c Efficient Water Heating 5c 1.5 1.5 (((��� <br />