Laserfiche WebLink
ATTACHMENT 4 TO EXHIBIT A <br /> Licensor Cable Test Results <br /> This document specifies the acceptance tests that were performed by Licensor and the <br /> manner in which such tests were accomplished and documented on the single mode fiber optic <br /> cable systems installed by Licensor to be licensed to Licensee. <br /> 1.0 CABLE SYSTEM <br /> 1.1 Configuration <br /> This type of cable system configuration is a two-ended cable system with splice points. <br /> 1.2. Tests That Were Performed <br /> Non-destructive attenuation tests utilizing a 1300 nm light source and optical power meter <br /> were accomplished from both ends of the two-ended cable system. End-to-end Optical Time <br /> Domain Reflectometer (OTDR) measurements were accomplished from both ends of the two- <br /> ended cable system. Splices(within the Licensor installed and spliced"link")were measured and <br /> documented during the construction process. <br /> 2.0 TEST RESULTS <br /> The following is a summary of the actual test results and identifies measured path loss: <br /> LESS THAN DB for total Licensor fiber length. <br /> 7 <br /> Fiber Optic Cable Master License Agreement <br />