EW GW WRAP ALL SIPES
<br /> TOMATCHE tan NG 1'-O" 2'-6" T-9" / )/ 2'-0" 1,-O"
<br /> / / / �
<br /> PLAN Nye LINETYPES
<br /> \ / ,_ \ EXI511NG WALL
<br /> ,1 *
<br /> N ,
<br /> �_ =
<br /> �� o / N / � > \ ® REMOVE GWB ENTIRELY FROM ALL EXTERIOR
<br /> <<___ _--/-
<br /> ! WALLS AND WOOD SIDING FROM UTILITY ROOM
<br /> /4,
<br /> \ \ N,FAN / WALLS. REMOVE TRIM FROM AROUND WINDOW
<br /> OPEN \ \ N / ROOF BELOW PROTECT SILL,JAMB AND HEAD DURING GWB REMOVAL
<br /> REF P-LAM READ REMOVE GWB ENTIRELY FROM ONE - -
<br /> o BOARp _ SIDE OF DEMISING WALL
<br /> ' BACKSPL.ASH 1 F,Jzo VS9PLASH
<br /> O.F.C.I, o 0 0 0 0 ��l �►'iir' �I " 1"�: ' • =■ '�• REMOVE PORTION OF CEILING ABOVE ,.......
<br /> / / .„- --- z N ---- . 0 ,-, .
<br /> 1- ,� MAX AREA 24'X 24'COORDINATE WITH r; ::: ::::::
<br /> O.1^.C.I. •
<br /> % % ID":
<br /> - I -� MEGH/ELEG DRAWINGS/SPECIFICATIONS
<br /> N /STOVE N / / _ ® DEMO ALL INTERIOR DOORS AND FRAMES,
<br /> 1 f� a i ALL CABINETRY,ALL PLYWOOD WALLS
<br /> RUBBER BASE ~ /1' O"� 2' 6" / 1' 9" / 3'-0" / 2' O" /7 0"I 21L
<br /> 21R AND ALL PLUMBING(EXCEPT TUB)
<br /> 22L • 22R . REMOVE GWB FROM FLOOR TO MAX 50"AFF
<br /> 0 INTERIOR WALL 0 PRIOR WALL
<br /> (@(0SIM REMOVE GWB COMPLETELY FROM
<br /> FLOOR TO CEILING)COORDINATE WITH NEW
<br /> • �1 y, .0 / ,
<br /> n• : INSTALLATIONS PER ELECTRICAL AND MECHANICAL
<br /> * �_6 '� 2 21L- .*--- I II I �i--..i-- (--1R) �* DRAWINGS FOR LOCATION AND EXTENT OF DEMO
<br /> ---- 1 RELOCATE VENT IN NEW WALL
<br /> 20L v 20R VERIFY WITH ARCHITECT AND MECH DWGS
<br /> � pN t r. — ON 7.1
<br /> _ la&
<br /> 2RC7
<br /> 1_7 Q REMOVE EXISTING VENT AND CONNECTING DUCT.
<br /> 7 \.A. \.
<br /> -�- (22LG/� EXISTING 1MNi70W \ (2OLG (20f�G ,
<br /> \ _
<br /> PUG WITH INSULATION AND COVER WITH
<br /> ` '� ' -- ,� t --� ei . VINYL SIDING(OFCI)TO MATCH EXISTING
<br /> 7. --- / 2OL I ORC ,., © C
<br /> Zv / V REMOVE CARPET AND CARPET PAD FROM ALL ROOMS
<br /> \ I \ —////. ///////.j :////' i ,< , • �3 l# ./C-7- f ' ,' i
<br /> \ 2 < O REMOVE BATHTUB SURROUND AND GWB PACKING
<br /> py,'LA6H / REF _ 0, REMOVE GLASS AND SLIDING DOOR SHOWER
<br /> P777//
<br /> / p1=,C,1, 2'O" 3'-2" '-2° �'0" ASSEMBLY PROTECT AND REINSTALL
<br /> 9A
<br /> /•/ / LEAR CLEAR CLEAR ��GL 2
<br /> - In
<br /> 1 REMOVE EXISTING TILE FLOORING FROM BATH AND
<br /> 7 ® 0 KITCHEN AND WHERE REMAINING IN OTHER ROOMS.
<br /> / 23L 23R OZ VERIFY ASBESTOS TILE LOCATIONS PRIOR TO BID
<br /> / ,
<br /> .7,
<br /> i �i RU EK BAD RUBI3 R.BASE ti �y�
<br /> / l�j I SUBMITTAL IF 9 x 9 OR 12 x 12 ASBESTOS TILE IS
<br /> l 23L� IN i (23R'G) ENCOUNTERED, CONTRACTOR SHALL FOLLOW PASAPCA
<br /> 0 EXTERIOR WALL ®INTERIOR WALL 23 C 3RC REQUIREMENTS FOR REMOVALAND DISPOSAL.
<br /> I I 4) NEW 1/2"TYPE"x'GWB OVER ,/r/ //�I
<br /> I I ELEVATIONS
<br /> 5 NEW 2 x 4 WOOD STUD CONSTRUCTION
<br /> SCALE 3/8{' -1'-0" - . NEW 1/2"GW13 OVER R-11(R 19 if2x6 CONSTRUCTION)
<br /> BAIT INSULATION @ALL EXTERIOR WALLS, INCLUDING
<br /> NEW TRIM TO MATCH @ EXTERIOR WINDOWS, DE
<br /> SECOND• L • 0 .° PLAN 6 MIL VAPOR BARRIER BETWEEN NEW GWB AND INSULATION.
<br /> CALE: 1/4" = 11-O" 4. NEW 5/8"TYPE'X'GWB OVER NEW RESILIENT , ..
<br /> i CHANNEL W/NEW SOUND BATT @ DEMISING WALL
<br /> ROOF BELOW
<br /> 0 . NEW 5/8"TYPE°x"GWB OVER NEW SOUND
<br /> II I I I I _
<br /> i?ATT INSULATION @ DEMISING WALL
<br /> r .
<br /> 1` h "—II It
<br /> �, �j, I -J � l - � � ® GRADEE PLYWOOD NEW RAM TUB SURROUND
<br /> SOUNDI/2"MARINEBATT IN DEMISING �-: .
<br /> (��rt'sq ! -nA 1� _ WALL EXTEND PLYWD 4'-10 ABOVE TOP OF TUB
<br /> ATTIC At710
<br /> ESg I ACCESS AND 1 INCH MIN TO EACH SIDE-SEE 5/A7.1
<br /> �js , t < r > 1 rr-
<br /> Q�®��--" " F r f ACCJ < .: .±LJ� I ......_
<br /> � c 4._
<br /> .___ //////���\\\ ® NEW WOOD HANDRAIL, RETURN ENDS TO WALL AS
<br /> ,\\ r •'r //. r r r f r r l f e r f 7 f ! S .. !r f x r ? r f (r••
<br /> Jr y�
<br /> , .
<br /> �[vt J INDICATED. LOCATE EXISTING STUDS FOR MOUNTING BRACKETS.
<br /> P as
<br /> ��.�m .• , . a ..r, I SEE FINISH NOTES.
<br /> a s „�,, I t
<br /> -_ i . - I I `A PROVIDE ONE CLOTHES ROD @6O'AFF AND
<br /> OS e e Z-1-7--$ ram 1 ��a. �..=a
<br /> TWO 14"DEEP MELAMINE SHELVES, TYPICAL
<br /> 4TYFc` 1 -I in
<br /> ili �/ -SS __ ► "a 1 I F ,
<br /> u ��V(�'(1Tii
<br /> Li_ IL -- ___ R i . NEW OPEN SHELVING IN UTILITY ROOM USE 1'MDF(PAINTED)
<br /> 8 4.4 �� ® COW x 12"D x 48"TALL @ 36"A.F.F. PROVIDE TWO INTERIOR
<br /> _ ! f ' L... i 1 A SHELVES EQUALLY SPACED LOCATION TO BE DETERMINED.
<br /> •<; LOCATE AND MOUNT ON EXISTING STUDS. VERIFY SIZE
<br /> ° ■ ,',
<br /> •.___ ^ �'-► AND LOCATION WITH OWNER.
<br /> CD
<br /> L 3'-; 44 2> . NEW 1/2"GWB ON ALL WALLS IN UTILITY ROOM
<br /> •
<br /> S...., 1 I
<br /> © I2 . EXCEPT 5/8"TYPE ?f @DEMISING WALL
<br /> ` ' 4t�ii 5IM ,O
<br /> SECOND FLOOR SECOND 2L - 0 HW 2R ,--; NEW WALL CARNET-PROVIDE SOLID BACKING
<br /> CENTER ABOVE TOILET
<br /> NEW FINISHED NEW FINISHED MODIFY EXISTING ROOF SHEATHING AND MEMBRANE
<br /> 0:0 OPENING-SEE F _: I --- OPENING-SEE n
<br /> _- v RE[F INTERIOR ELEV U KITCHEN TO ACCOMODATE NEW DUCTS PENETRATING ROOF-SEE MECH
<br /> KITCHEN INTERIOR ELEVE, r ► PROVIDE TWO NEW LOCKS PER SPECIFICATIONS
<br /> KITCHEXHAE:iT ExHAUSrjflfl9
<br /> 0.1=.C.I. 0.1=,C.L TO SECURE ATTIC ACCESS DOOR
<br /> f ..1 >, ® PATCH ALL DAMAGED AREAS RESULTING FROM
<br /> BEAM BEAM u u u u . . ,
<br /> , , a ,fin
<br /> .1101111 5'_O" 3'-6" t , i 3'-6" '-0" DEMOLITION. REFER TO DEMOLITION PLANS FOR AL.LAREAS.
<br /> 13410101
<br /> o 0 1C 11�G� f o
<br /> FIELD VERIFY AND COORDINATE WITH ELECTRICAL
<br /> �rn, F 1 LC 1 RC AND MECHANICAL SUB-CONTRACTORS FOR
<br /> 1 �::::.; ADDITIONAL FPROVIDE SOLID BACKING ALONG ALL EDGES.INSTALLATIONS.
<br /> _i z SHELF SHELF
<br /> TYP 1 ' k<krillis I- a+� REPAIRA D REINSTALL AS REQUIRED ALL
<br /> N
<br /> .---)\-"
<br /> I-I 51M 51M': �-_ Li-----\
<br /> EXISTING ACCESS DOORS AT BATHTUBS,TYP.
<br /> , HW HW , ' 1 TYP y
<br /> a �ae::::::::' arm _ • i tea u a
<br /> �,. . //� ® with CONSTRUCT NEW DRAFTSTOPAS REQUIRED BY USG 706.
<br /> „ ` IN ATTIC-IN LINE WITH UNIT DEMISING WALLS.
<br /> ` ,' IL 1R 4% INSTALL P.T.WOOD BLOCKING @ 4'-0"O,C.TO SUPPORT GAS
<br /> Mr Q PiPiNG, FASTEN BLOCKING TO WALL. . '= El; ® C UT� ° \ ° UP + REPLACE DAMAGED GWB WITH NEW TYPE X GWB TO MATCH.
<br /> i ■
<br /> J - _ _ 1 � . 7 AL NOTES:
<br /> I ." `' '
<br /> -
<br /> 1. SEE SITE PLAN FOR
<br /> ILDING
<br /> "„x•:IL: u `� - 2. INSTALL FIRE BLOCKING BETWEEN STUDS @48"AFF
<br /> N
<br /> PATCH ALL DAMAGED AREAS RESULTING FROM IN ALL NEW WALLS S AND EXISTING WALLS WHERE
<br /> FIRST FLOM FIRST FLOOR DEMOLITION. REFER TO DEMOLITION PLANS FOR ALL AREAS. FRAMING HAS BEEN EXPOSED
<br /> FIELD VERIFY AND COORDINATE WITH ELECTRICAL NOTE: ALL WORK INDICATED 13 TYPICAL
<br /> DEMOLITION L..AN ® n ar& SECOND FLOORS KEFLECTEP CEILING PLANS - Fw5r&SECOND FLOORS 1 AND MECHANICAL WORK SUB-CONTRACTORS RS FOR NOTE: SEE I PLAN AND I5 TO I3E COMPLETED IN ALL •
<br /> SCALE: 1/�" = 1' c�' ADDIT1oNAL REPAIR WORK DUE TO NEW INSTALLATIONS. LING
<br /> { APARTMENT UNITS WHETHER INDICATED
<br /> = 1'-C7' SCALE: 118"= 1'-O" PROVIDE SOLID BACKING ALONG ALL EDGES. 0 I L ) Ifil 11I IN THAT SPECIFIC APARTMENT RTMENT OR NOT
<br /> _ _ _
<br /> '" ROMIN 4941 REGISTERED SHEET 2
<br /> RANDA w ApARTmENTs
<br /> �' ARC T
<br /> TYPEAA
<br /> V R�TT FRANK G. STICKNEY 0 RONALD F. MURPHY o MICHAEL W.ROMINE, ARCHITECTS PLLC MICHAEL IINMINE DATE: 16,1998
<br /> ED R THEHO USING AUTHORITY OF THE CITY OF E STATE OF WASHINGTON DRAWN BY: VMA PERMIT APPLICATION a 1
<br /> 911 WESTERN AVENUE, SUITE 200, SEATTLE, WASHINGTON 98104 0 (206)623 1104 __ -•-_-____..._
<br /> CHECKED: OF 12 SHEETS
<br />
|